• Title/Summary/Keyword: 냉각기계

Search Result 1,055, Processing Time 0.029 seconds

냉각탑의 선정방법

  • 소헌영
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.12
    • /
    • pp.31-37
    • /
    • 2003
  • 냉각탑의 성능저하방지와 에너지절감 및 민원 발생방지를 위한 형식, 용량, 배치, 설치의 최적 선정 방안을 제시한다.

  • PDF

Modeling of Cooling Channels of Injection Mould using Functionally Graded Material (기능성 경사 복합재를 이용한 사출금형의 냉각회로 모델링)

  • Shin, Ki-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1647-1653
    • /
    • 2011
  • The cycle time in injection moulding greatly depends on the cooling time of the plastic part that is controlled by cooling channels. Cooling channels are required to facilitate the heat transfer rate from the die to the coolant without reducing the strength of the die. Employing layered manufacturing techniques (LMT), a die embedding conformal cooling channels can be fabricated directly while conventional cooling channels are usually made of straight drilled hole. Meanwhile, H13 tool steel is widely used as the die material because of its high thermal resistance and dimensional stability. However, H13 with a low thermal conductivity is not efficient for certain part geometries. In this context, the use of functionally graded materials (FGMs) between H13 and copper may circumvent a tradeoff between the strength and the heat transfer rate. This paper presents a method for modeling of conformal cooling channels made of FGMs.

재생냉각용 연소기의 브레이징 공정 개발

  • 홍석호;한규석;우유철
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.36-36
    • /
    • 2000
  • 액체로켓엔진에 사용되는 2000psi이상의 고압 연소실(Combustion Chamber)의 냉각은 내피(Inner Shell)에 기계 가공된 냉각통로(Cooling Channel)로 냉각제를 흘려보내는 재생냉각방식이 널리 사용되며 기계 가공된 냉각 통로는 외피(Outer Shell)에 의해서 지지 밀봉된다. 일반적으로 내피 재료는 순수한 구리보다 강도가 우수하고 열전도도는 유사한 구리합금을 사용하고, 외피는 강도가 우수한 스테인레스 강을 사용하여 브레이징 접합된 구조를 형성한다. 브레이징 공정은 조립품을 약 $450^{\cire}C$ 이상의 액상선을 갖는 삽입금속(Filler Metal)을 사용하여 적당한 온도($450^{\cire}C$ ~ 모재의 고상선)에서 가열하여 접합시키는 방법으로, 용융 금속의 젖음 현상(Wetting Phenomena), 접합 틈새(Joint Clearance)로의 용융 삽입금속의 유입(Capillary Phenomena)과 접합 계면의 반응을 통해서 접합이 이루어진다. 이는 일반적인 접합 공정과 비교하여 모재의 변형이 적고, 이종 금속 간의 접합이 용이하며, 복잡한 부품을 정밀하게 접합할 수 있는 장점이 있으나, 접합될 제품의 표면 상태 및 분위기(Atmosphere), 접합될 부품간의 조립 틈새, 가열 싸이클(Heating Cycle) 등에 대한 공정 확립 및 관리가 매우 중요하다. 재생냉각 구조를 갖는 연소실은 우선 접합면의 형상이 매우 복잡하여 균일한 접합 틈새를 유지하면서 접합시키기가 매우 어려우며, 고온, 고압의 환경에서 작동하므로 일부 접합면이 접합되지 않을 경우 내피의 변형 및 파괴가 발생하고, 브레이징 시 용융된 삽입금속이 냉각통로 내로 유입될 경우 연소 시 이부근에서 재료의 용융이 발생될 수 있다. 따라서, 이러한 현상을 방지하기 위해서는 진공 분위기 하에서 적절한 접합 틈새를 유지할 수 있는 공정 및 장비의 개발이 필요하다.

  • PDF

Effects of Micro-fin Structure on Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region (강제대류 및 핵비등영역에 있어서 마이크로 휜 형상이 분무냉각 열전달에 미치는 영향)

  • Kim, Yeung-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.983-990
    • /
    • 2010
  • In the present study, spray cooling heat transfer was experimentally investigated for the case in which water is sprayed onto the surfaces of micro-fins in forced convection and nucleate boiling regions. The experimental results show that an increase in the droplet flow rate improves heat transfer due to forced convection and nucleate boiling in the both case of smooth surface and surfaces of micro-fins. However, the effect of subcooling for fixed droplet flow rate is very weak. Micro-fins surfaces enhance the spray cooling heat transfer significantly. In the dilute spray region, the micro-fin structure has a significant effect on the spray cooling heat transfer. However, this effect is weak in the dense spray region. A previously determined correlation between the Nusselt number and Reynolds number shows good agreement with the present experimental data for a smooth surface.

고리1호기에 대한 냉각재상실사고해석

  • 차종희
    • Journal of the KSME
    • /
    • v.16 no.2
    • /
    • pp.6-14
    • /
    • 1976
  • 원자로의 안전성확보의 기본은 원자로의 운전에 의한여 발새하는 방사성 물질을 확실하게 관리하 여 방사서의 해로부터 공중의 건강과 안전을 보존하는 것이다. 원자로에는 로내의 방사성물질인 핵분열생성물의 누설을 방지하는 일련의 독립적 방벽들 즉 연료의 피복제, 원자로용기를 포함하 는 일차냉각재계용, 그리고 일차냉각재계통을 수용하는 격납용기들로 된 다중방호벽이 마련되어 있다. 원자로설계기준에서는 이들 방호벽이 어떠한 가상적사고가 발생하여도 그 건전성이 유지되 도록 요구하고 있디. 우리나라에서도 미국의 기준을 준용하는 원칙으로 고리 원자력발전소 등 1 호기에 대한 해석이 수행되었던 것이다. 여기서 해석판정기준 및 해석결과를 소개하고저 하는 것이다.

  • PDF

鋼材의 水冷却에 있어서의 傳熱現像 (I)

  • 최국광
    • Journal of the KSME
    • /
    • v.20 no.6
    • /
    • pp.468-473
    • /
    • 1980
  • 강재의 냉각, 특히 물을 사용한 강제냉각은 제철공정에서 실용되어지고 있음에도 불구하고 그 냉각과정에서 어떠한 현상이 일어나고 있는 지는 아직까지 명확치 못한 부분도 많고, 열전달율의 정량\ulcorner인 값도 불확실한 부분이 많다. 석유 shock 이래, energy 사용의 절약을 부르짖는 이때 물 상용의 절감 또한 절실히 요구되고 있다. 따라서 철강관계자도, 전열관계자도 이방면에 중대한 관심을 기울이게 됨은 물론 연구는 문의 수도 점차로 늘어나기 시작했다. 제철공정에서 가장 중요한 부분을 차지하는 온도범위는 감재표면열도의 200-1300.deg.C정도사 이 이지만 이중 300-800.deg.C 정도 범위에서는 인체면과 물사이의 전열현상을 가장 잘 알지 못하는 범위이다. 이범위의 실험치를 개관하면 실험하는 사람에 따라서 열전달율에 약간의 정도차가 있으며, 아 직까지 연구의 단서만 나온 것 뿐이라는 관점이다. 강재냉각의 전망에 대해서는 삼봉의 훌륭한 교재가 있으며, 본자료에서 는 냉각하는 경우에 생기는 현상을 중심으로 전열연구자의 입장에서 연구현황과 그 문제점을 논술해 보고자 한다.

  • PDF

원자로 효율 향상을 위한 이중냉각핵연료 유동설계 방안

  • Jo, Hyeong-Hui;Kim, Gyeong-Min;Kim, Tae-Hwan;In, Wang-Gi;Sin, Chang-Hwan
    • Journal of the KSME
    • /
    • v.52 no.3
    • /
    • pp.32-36
    • /
    • 2012
  • 이 글에서는 가압경수로의 성능 향상을 위해 연구 중인 이중냉각핵연료를 소개하고, 성능 향상을 위해 수행 중인 실험 및 수치해석을 이용한 유동설계 방법을 소개하고자 한다.

  • PDF