• Title/Summary/Keyword: 냉각곡선

Search Result 115, Processing Time 0.029 seconds

Efficient Rate Control by Lagrange Multiplier Using Adaptive Mode Selection in Video Coding (비디오 코팅시 Lagrage 승수를 조정하여 적응 모드 선택에 따른 비트율의 제어)

  • Ryu, Chul;Kim, Seung P.
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.77-88
    • /
    • 2000
  • This paper presents an approach for rate control by adaptively selecting macroblock modes in video coding.The problem of rate control has been investigated by many authors where quantizer level is adjustedbased on the buffer fullness. The proposed approach is different fron the previous ones [4] id that it finds the optimal decision curve rather than finding a set of the modes. Proposed algorithm extends the coding decision options for rate control to motion/no-motion compensation as well as inter/intra decisions. Instead of having a fixed motion/no-notion compensation or inter/intra decision curve, one can utilize an adaptive decision curvebased on the characteristics of input frames so that the PSNR at a given bit rate is maximized. Therefore, the proposed approach provides better rate control than simple quantizer feedback approach interns of visual quality. The curve is obtained by utilizing simulated annealing optimization technique. Thealgorithm is implemented and simulations are compared with other approaches within H.261 video codec.

  • PDF

PWR 정지시 일차계통 산성-환원 및 산화단계의 용존기체 제어조건

  • 성기웅;강덕원;성기방;정홍호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.357-362
    • /
    • 1998
  • PWR 정지시 일차계통 수화학 제어의 주요대상은 계통표면에 침적된 부식생성물의 주성분인 비화학양론적 니켈(코발트)페라이트로서, 산성-환원 단계에서 용존수소에 의해 Ni$^{\circ}$ (또는 Co$^{\circ}$)로 환원되고 산성-산화 단계에서 용존산소에 의해 Ni$^{2+}$ (또는 CO$^{2+}$)로 산화되어 이온교환기에 의해 제거된다 본 연구에서는, 니켈 및 코발트 산화물의 25~300 $^{\circ}C$ 환원 또는 산화반응 시 표준자유에너지의 변화 및 용존수소 또는 용존산소의 요구농도를 계산하여, 원자로 정지시 일차계통수 용존 기체의 제어조건을 고찰하였다. 산성-환원 단계의 냉각재 온도인 300~82$^{\circ}C$ 범위에서 용존수소가 충분할 경우 열역학적으로 $^{58}$ Co(또는 $^{60}$Co)Fe$_2$O$_4$$\longrightarrow$Co의 역반응이 억제되므로서 노심외 계통부위 침적이 감소될 수 있기 때문에, 용존수소를 온도에 따라 요구농도 곡선 위로 약간 높게 유지하는 것보다 25~50 cc/kg-$H_2O$로 유지하는 방식이 바람직한 반면, 용존산소를 제공하는 과산화수소 농도가) 2.7 ppm일 때 NiFe$_2$O$_4$$\longrightarrow$Ni$_2$O$_4$(+$\alpha$-Fe$_2$O$_3$) 반응이 일어날 수 있기 때문에, 산성-산화 단계에서는 과산화수소의 냉각재 농도를 이보다 낮게 유지하는 것이 바람직하다.

  • PDF

Prediction of Hydraulic Performance of a Scaled-Down Model of SMART Reactor Coolant Pump (스마트 원자로냉각재펌프의 축소모형에 대한 수력성능 예측)

  • Kwon, Sun-Guk;Park, Jin-Seok;Yu, Je-Yong;Lee, Won-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1059-1065
    • /
    • 2010
  • An analysis was conducted to predict the hydraulic performance of a reactor coolant pump (RCP) of SMART at the off-design as well as design points. In order to reduce the analysis time efficiently, a single passage containing an impeller and a diffuser was considered as the computational domain. A stage scheme was used to perform a circumferential averaging of the flux on the impeller-diffuser interface. The pressure difference between the inlet and outlet of the pump was determined and was used to compute the head, efficiency, and break horse power (BHP) of a scaled-down model under conditions of steady-state incompressible flow. The predicted curves of the hydraulic performance of an RCP were similar to the typical characteristic curves of a conventional mixed-flow pump. The complex internal fluid flow of a pump, including the internal recirculation loss due to reverse flow, was observed at a low flow rate.

Evaluation of Effects of Rare Earth Element and Cooling Rate on the Eutectic Reaction of Flake Graphite Cast Irons by Cooling Curve Analysis (냉각곡선 분석을 통한 편상흑연주철의 공정반응에 미치는 희토류원소 및 냉각속도의 영향 평가)

  • Lee, Sang-Hwan;Park, Seung-Yeon;Lee, Sang-Mok;Kim, Myung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.33 no.1
    • /
    • pp.13-21
    • /
    • 2013
  • The effects of rare earth element (R.E.) and cooling rate on the eutectic reaction of flake graphite cast irons were studied by combined analysis of macro/micro-structure and cooling curve data. The correlation between eutectic reaction parameter and macro/micro-structure was systematically investigated. Two sets of chemical compositions with the different addition of R.E. were designed to cast. Three types of molds for cylindrical specimens with the different diameters were prepared to analyze cooling rate effect. The difference between undercooling temperature and cementite eutectic temperature (${\Delta}T_1=T_{U}-T_{E,C}$), which is increased by adding R.E. and decreased by increasing cooling rate, is considered to be a suitable eutectic reaction parameter for predicting graphite morphology. According to the criterion, A-type graphite is mainly suggested to form for ${\Delta}T_1$ over $20^{\circ}C$. Eutectic reaction time (${\Delta}t$), which is decreased by adding R.E. or increasing cooling rate, is a suitable eutectic reaction parameter for predicting eutectic cell size. Eutectic cell size is found to decrease in a proportion to the decrease of ${\Delta}t$.

A Study on the Local Boiling of the Consolidated Spent Fuel Storage Pool (조밀화된 사용후 핵연료 저장조에서의 국부 비등에 관한 연구)

  • Lee, Chang-Ju;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.8-19
    • /
    • 1993
  • The natural convection model of the consolidated system has been developed to make sure the removal of decay heat generated in the spent fuel for the loss of forced cooling accident. The numerical technique employed was based on the ADI scheme. The calculation of heat generation rate in the spent fuel was peformed by the ANS-79 decay heat model, and the nonuniform surface heat flux is assumed with a chopped sine curve for the conservative decay heat generation input. The sensitivity study was performed to examine the possibility of the pool bulk boiling by varying the various parameters, i.e. inter-fuel spacing ratio, heat generation power, and radius of the fuel rod. The application results of this model show that the natural circulation flow through compacted spent fuel bundles enables the pool temperature to control in a safe and effective manner, after the required cooling time. The corresponding acceptance criteria of the cooling time for rearranging the spent fuel rods were also found.

  • PDF

Analysis on Po1y(lactic acid) Melt Spinning Dynamics (Poly(lactic acid) 용융방사공정의 동역학 해석)

  • Oh, Tae-Hwan;Kim, Seong-Cheol
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.245-252
    • /
    • 2009
  • Profiles development of melt spinning process of poly(lactic acid) (PLA) was simulated via a numerical method and the radial temperature distribution was calculated using finite difference method. The spinning speed ranged from 1 km/min to 5 km/min was analyzed and the effect of spinning conditions on the radial temperature distribution was investigated. At low spinning speed, the difference between PLA and poly(ethylene terephthalate) (PET) was relatively small. As the spinning speed increased, the difference in velocity profile became prominent. PLA showed a slower spinning speed than PET and solidified more slowly. The temperature difference between the core and surface of the PLA filament reached 4.6 K, which was less than that of PET filament with a difference of 10.4 K. The radial temperature difference increased with increasing the cooling-air velocity and the spinning temperature.

THE SLOPE OF ΔM LIGHT CURVE DEPENDING UPON THE ITS LOCATION IN CCD FRAME (CCD 이미지 상의 그 위치와 ΔM 광도곡선의 기울기)

  • 정장해;임인성
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2002
  • BV observations for V523 Cas were performed with 1.8m telescope and 2K CCD camera at Bohyunsan Optical Astronomy Observatory, Korea, on October 27, 1999. ${\Delta}m$ light curves for 11 comparison objects were made. It was found that their light curve slopes are different each other. Factor analysis for items of slope, (b-v) , magnitude, X pixel, and Y pixel results that there is strong correlation between the slope and the location (X,Y). It might be due to problems of CCD cooling system.

Heat Transfer Characteristics for Inward Solidification in a Horizontal Cylinder Packed with P.C.M. (상변화물질을 충전한 수평원통관 내에서 응고시 열전달특성)

  • Yum, Sung-Bae;Hong, Chang-Shik;Lee, Chai-Sung
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.51-62
    • /
    • 1991
  • Heat transfer characteristics for heat retrieving processes in a paraffin-filled horizontal circular cylinder was studied. Theoretical and experimental analyses were carried out. In the theoretical analysis, solid and liquid phases were treated separately. Namely, convection for liquid and conduction for solid phase were investigated respectively. The retrieved heat was calculated from the experimentally determined solidified mass. Furthermore, the effects of initial temperature of the liquid and cooling temperature on the heat discharge rate were also studied. In the heat retrieving process, the governing factor for the solidifying rate is the cooling temperature, because most of the liquid sensible heat is rapidly discharged in the initial stage of solidification. Hence heat transfer mechanism during heat retrieving process can be safely considered as conduction. In the cut of frozen paraffin, there showed an empty space in the upper region. It is caused by the temperature drop in the liquid paraffin. While volume shrinkage caused by phase transition was indiscernible. Irrespective of cooling temperature and initial liquid temperature, solidified mass was well-correlated with the product of Fourier number and Stefan number in the solid phase.

  • PDF

A Study on P-M Interaction Diagram of Fire-Damaged High Strength Concrete Column (화재 피해를 입은 고강도 RC 기둥의 P-M 상관곡선에 관한 연구)

  • Kim, Hyun-Jung;Choi, Eun-Gyu;Shin, Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.257-260
    • /
    • 2008
  • This study will make P-M interaction diagram of residual capacity at fire-damaged High strength concrete column with polypropylene fiber. Evaluating capacity of column decreasing spalling with P-M interaction diagram is important. because high strength concrete column with polypropylene fiber isn't section area loss. P-M interaction diagram that is made to analyze according to a various parameters is useful index for design and evaluating capacity of columns. In this study, spalling, temperature distribution of interior column, residual strength and movement of column in eccentric loading are studied with expose time of high temperature. For study fire test that is similar real act, and after cooling in normal condition residual strength of specimen is estimated. And this study use DIANA(Displacement Analyzer) for analyzing nonlinear analysis. with experiment temperature and strength data.

  • PDF

The effect of cooling an impaction plate on impactor performance (환경입자제어용 관성충돌기의 충돌판 냉각에 따른 효율곡선의 변화)

  • Lee, Byung-Uk;Kim, Sang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.596-599
    • /
    • 2001
  • Recently, as the environmental pollution becomes an important issue, aerosols which are the main components of the atmospheric pollution become the subject of a lot of researches. An impactor is a kind of sampling and measuring equipment for aerosols since 1970s. The impactor uses coating materials to obtain high performance. However, there are a lot of situations when coating materials are not available and in this case the classification efficiency of the impactor decreases significantly. In this study, the impaction plate of the impactor is cooled, therefore the impactor performs efficiently when coating materials are not available.

  • PDF