• 제목/요약/키워드: 냄새유발(이취미)물질

검색결과 4건 처리시간 0.022초

부영양호 원수의 냄새유발 물질 탈기 특성 (Air stripping of odor causing materials from eutrophic lake water)

  • 박노백;송용효;나광주;박상민;전항배
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.523-529
    • /
    • 2008
  • Algal blooms in a local eutrophic lake often produces the musty and earthy taste & odor problems. Since the odor causing compounds(OCCs) including geosmin and 2-MIB have their own volatility, the OCCs can be removed from water by air stripping methods. Removal of TON(threshold odor number) as an index for OCCs could be fitted well with the first order equations($R^2=0.9$ above), where the air stripping coefficient of TON, k was in the range between 0.0055 and 0.0097 according to the aeration time. k within 30min aeration tests was 0.0097, while it was 0.0055 where the aeration time extended to 150min. With 15 mg/L of PAC, removal of TON was not simulated with 1st order equation within 30min aeration. Within 30min aeration, OCCs rather than geosmin and/or 2-MIB could be removed easily by air stripping or PAC adsorption, while OCCs such as geosmin and/or 2-MIB could be removed slowly by air stripping after 30min aeration. Geosmin and 2-MIB were not readily removed by air stripping(k of them were 0.0018~0.0047 and 0.0018~0.0034, respectively at different air flow rates). Geosmin could be removed by air stripping a little better than 2-MIB.

분말활성탄 흡착 및 탈기에 의한 이취미 제거 (Removal of Taste and Odor by Powdered Activated Carbon Adsorption and Air Stripping)

  • 전항배;나광주;서태경;박상민
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.455-460
    • /
    • 2008
  • Powered activated carbon(PAC) has been widely applied for controling odor causing compounds(OCCs) from water treatment plants. Because of their volatility, the OCCs can also be removed from water by air stripping methods. In this study, OCCs removal was tested with PAC adsorption, air stripping, and both PAC adsorption and air stripping from the Taecheong lake water. Removal efficiency of OCCs in terms of threshold odor number(TON) were 39.6% by both PAC (15mg/L) adsorption and aeration for 30 min, 33.6% by PAC(15mg/L) adsorption alone for 30 min, and 22.9% by aeration alone for 30 min, respectively. OCCs could be removed up to 50% by aeration for 120 min without PAC adsorption. At an extended aeration with 15mg/L of PAC, OCCs removal occurred mainly by PAC adsorption within 30 min aeration while it continued by air stripping afterward. At simulated jar tests with the raw water, removal efficiencies of geosmin and MIB were 48.3, 36.1% by coagulation and sedimentation without PAC addition. With 15mg/L of PAC on the same jar tests, the removal efficiencies were 83.1, 60.1%, respectively. Without PAC, OCCs could be possibly removed by stripping during the agitation processes.

분말 활성탄에 의한 먹는 물 내의 이취미 물질 제거 (Removal of Geosmin and 2-methylisoborneol in Drinking Water by Powdered Activated Carbon)

  • 채아나;신재원;조강우;이병찬;송경근
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.475-483
    • /
    • 2017
  • 녹조현상 발생시 남조류에 의하여 발생하는 이취미 물질인 Geosmin과 2-methylisoborneol(2-MIB)는 수돗물에 냄새를 유발하는 원인 물질로서 제거가 필요하다. 일반적으로 정수장에서는 이취미 물질의 제거를 위하여 활성탄을 사용하고 있으나 활성탄의 기공 분포와 활성탄의 입자크기가 이취미 물질 흡착제 미치는 영향에 대한 정보는 부족하다. 따라서, 본 연구에서는 다양한 활성탄의 기공분포와 활성탄의 입자 크기가 이 취미 물질 흡착에 미치는 영향을 살펴보았다. 분말활성탄(PAC), 입상활성탄(GAC), 활성탄소섬유(ACF)의 이취미 물질 흡착을 비교한 결과, PAC > ACF > GAC 순서로 이취미물질 흡착제거효율이 높았다. 다양한 기공분포 특성을 갖는 분말활성탄들을 비교한 결과, 미세기공이 잘발달된 경우가 Geosmin과 2-MIB의 흡착에 유리한 것으로 나타났으며, 입자 크기의 경우에는 작을수록 Geosmin과 2-MIB의 흡착에 보다 효과적이었다.

PAC를 이용한 2-MIB와 Geosmin의 흡착특성과 제거에 관한 연구 (The Removal and Adsorption Characteristics of 2-MIB & Geosmin using PAC)

  • 전대영;이현주;홍성호;윤제용
    • 대한환경공학회지
    • /
    • 제22권11호
    • /
    • pp.2097-2104
    • /
    • 2000
  • 자연계에서 발생하는 이취미 문제는 주로 조류나 박테리아와 같은 미생물의 신진대사에 기인한다. 이취미와 관련한 원인물질은 주로 MIB와 Geosmin으로서 이는 9ng/L와 4 ng/L의 아주 저농도에서도 흙과 곰팡이 냄새를 일으킨다. 정수처리공정에서는 분말활성탄을 이용한 이취미 유발물질 제어기술이 잘 알려져 있다. 본 연구에서는 단일성분과 이성분계에 있어서의 흡착등온실험을 통하여 최적의 PAC 투여량과 반응시간에 대하여 고찰하였으며 또한 원수를 이용하여 수중에 포함된 자연유기물질의 영향을 고찰하였다. 연구결과 자연유기물질의 유무에 관계없이 Geosmin의 흡착능이 우수하였으며, 자연유기물질이 존재할 경우 MIB와 Geosmin 모두 4배 정도의 흡착능 저하를 보였다. 초기농도 100ng/L 정도의 원수의 경우 99%의 제거율을 얻기 위해서는 PAC 투여량 20mg/L, 4시간 이상의 반응시간을 필요로 하였다.

  • PDF