• 제목/요약/키워드: 내화 구조성능

검색결과 296건 처리시간 0.034초

비금속관 설비관통부의 슬리브 종류에 따른 내화성능 비교 (Comparison of the Fire Resistance Performance of Firestop Systems on Non-Metallic Pipes, Based on the Type of Through-Penetration Sleeve Used)

  • 정아영;최홍범;박진오;이형도
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.301-302
    • /
    • 2023
  • In this study, we aimed to identify changes in fire resistance according to the type of sleeves used for pipe penetrations and to examine their accreditation of fire resistance performance and use them as basic data. The test results of fire resistance according to the type of sleeve used in non-metallic pipe facilities showed that the temperature on the support side was higher for sleeves with higher thermal conductivity. For the temperature on the surface of the pipes, in the case of galvanized steel plates, steel pipes, and structures without sleeves, the highest temperature was observed after the expansion of the firestop material for 46 to 53 minutes and then decreased. PVC sleeves showed a steady increase in temperature until 53 minutes, after which the temperature did not increase further. In addition, for non-metallic pipes, the effect of the type of sleeve on fire resistance is considered to be insignificant because the lower part (heating direction of the furnace) under the support structure is cut off to block the heat during the two-hour fire resistance test.

  • PDF

고온과 편심 축하중을 받는 세장한 철근 콘크리트 기둥의 유한요소해석 (Finite Element Analysis of Slender Reinforced Concrete Columns Subjected to Eccentric Axial Loads and Elevated Temperature)

  • 이정환;김한수
    • 한국전산구조공학회논문집
    • /
    • 제35권3호
    • /
    • pp.159-166
    • /
    • 2022
  • 본 논문에서는 유한요소해석 프로그램 Abaqus를 이용하여 고온과 편심 축하중을 받는 세장한 철근 콘크리트 기둥의 유한요소해석 절차를 제시하고 해석 결과를 비교·분석하였다. 기둥에 축하중과 화재가 가해지는 상황을 해석에 반영하기 위해 Abaqus에서 제공하는 순차 결합 열-응력 해석을 사용하였다. 우선 콘크리트 단면에 대한 열전달 해석을 수행하여 검증한 뒤, 이를 3차원 요소로 확장하고 구조해석과 결합하여 해석을 수행하였다. 해석 과정에서 수렴성 및 정확성에 영향을 미치는 인장 증강 효과와 초기 불완전성을 고려하여 모델링하였다. 해석 결과는 74개 실험 데이터와 비교하였으며, 내화시간을 기준으로 평균 6%의 오차를 나타냄에 따라 유한요소해석을 통해 철근콘크리트 기둥의 내화성능을 예측할 수 있게 되었다.

탄소섬유쉬트 보강 콘크리트용 무기계 폴리머 접착제의 내화 및 구조성능 (Structural Performance and Fire Resistance Capacity of Inorganic Polymer Composites for Carbon Sheets Exposed to High Temperature)

  • 정란;박현수
    • 콘크리트학회지
    • /
    • 제10권5호
    • /
    • pp.109-115
    • /
    • 1998
  • 철근콘크리트 구조물이 과소설계되어 있거나 과다 하중이 작용하게 되면 그 구조물의 구조성능을 파악하여 보수.보강을 시행하게 된다. 최근에 가장 맣이 사용되는 보수.보강 재료로는 특히 휨내력을 보강하는데 탄소섬유를 들 수 있다. 탄소섬유쉬트는 내열성과 내호염성에 있어서 회재가 발생할 경우 보강재료로서 충분한 성능을 가지고 있다. 그러나 이를 접착시키는데 사용되는 에폭시는 유기계 물질로서 화재시 유독가스가 발생하고 내열성능도 30$0^{\circ}C$정도에도 지탱하기 어려워 화재 발생이 가능한 구조물에 사용하기 어렵다. 이 연구에서는 무기계 폴리머 복합재료로 접착된 탄소섬유를 고온(약 800~100$0^{\circ}C$, 1시간)으로 가열한 후 가열된 섬유판의 인장, 휨 전단내력을 검토하여 내열성능을 파악하고 이 섬유쉬트로 보강한 철근콘크리트 부재의 휨 성능을 실험적으로 규명하여 화재의 위험이 있는 구조물에 구조적인 보강재료로 사용이 가능한가를 검토하였다. 연구 결과, 개발된 무기계 폴리머 복합체는 인장강도, 휨강도 및 접착강도가 유기계 접착제와 유사하게 나타났고 800~100$0^{\circ}C$ 정도로 1시간 가열한 이후에도 상온 시험체 휨내력과 전단내력의 63%, 33% 정도를 유지하여 화재의 위험이 있는 부위에도 사용이 가능한 것으로 판단되었다.

고강도 용접구조용 강재 적용 장스팬 보부재의 해석적 내화성능 비교 연구 (Comparative Study for Long Span Beams built up with Sub-marine High Strength Structural Steels at High Temperature using Analytical Method)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.120-121
    • /
    • 2016
  • Recently, the building has been changed into high-rise and long span and this yields a development of high performance structural steels in construction market. According to this effect, the SM 520 and the SM 570 were developed and utilized into steel building industry. However, the study for fire resistance of them were not done actively. In this study, to know and comparative the fire resistance performance of long span beams built up with high strength structural steels an analytical method is going to applied using mechanical and thermal properties at high temperature.

  • PDF

화재피해를 입은 철근콘크리트 단주시험체의 보수재료 적용 후 내화성능 평가 (Fire Resistant Performance after Application of Repaired Materials for Fire-Damaged Reinforced Concrete Column)

  • 심상락;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.147-154
    • /
    • 2020
  • Currently, there are no specific repair methods for RC structures damaged by fire, and repair methods are applied when durability deteriorates due to aging. In addition, a number of recent studies have been reported that have conducted fire resistance assessment of the repair materials themselves, assuming exposure to high-temperature environments such as fires. However, researches that evaluate the fire resistance performance of the repair materials by applying existing repair materials to the actual fire damaged reinforced concrete structures are very rare. Therefore, in this study, a number of existing repair materials were applied to fire-damaged concrete column to compare and evaluate the fire resistance performance with the original cover concrete.

일반 구조용 강재 적용 H형강 보부재의 해석에 의한 고온내력 평가 연구 (Evaluation of Structural Stability at High Temperature for H-section Beams Made of Ordinary Strength Steels by Analytic Method)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.76-81
    • /
    • 2014
  • 화재와 같은 고온 시 구조부재의 붕괴를 방지함으로써 재실자와 소방관계자 그리고 재산을 보호할 수 있는 방법은 구조부재의 내화성능을 확보하는 것이며, 이는 시방적 내화설계방법인 내화시험을 통하여 확보되어 왔다. 그러나 내화시험에 수반되는 시험체 제작과 운반 그리고 막대한 시험 비용의 반복적 사용 등은 새로운 공법과 재료 개발의 문제점으로 대두되었다. 따라서 본 연구에서는 일반 등급(SS 400) 강재의 고온 시 항복강도, 탄성계수와 열전달 및 열응력 해석을 적용하여 H형강 보부재의 표면온도 상승 및 고온 시 내력 변화를 평가하였다. 또한 H형강 보부재의 길이 변화에 따른 고온 시의 보부재의 내력평가를 수행하여 각각의 길이변화에 따른 내력 변화의 차이를 평가하였다.

방호·방폭 보강용 복합패널의 재료특성에 관한 연구 (A Study on Material Properties of Composite Panel for Impact·Blast Resistance)

  • Kim, Woonhak;Kang, Seokwon
    • 한국재난정보학회 논문집
    • /
    • 제12권4호
    • /
    • pp.373-380
    • /
    • 2016
  • 본 연구에서는 기존 구조물의 방호 방폭에 대한 보강 방법으로서 프리캐스트 패널의 단층구성 재료에 경량성, 고강도, 내화성능 등을 향상시켜 단층 각각의 개별적인 특수성능과 복합적인 패널 구성물로서 방호 방폭 성능을 극대화 할 수 있는 복합섬유 패널을 제작하기 위해, 아라미드섬유(Aramid Fiber, 이하 AF)와 폴리에스터섬유(Polyester Fiber, 이하 PF)로 혼합된 내피와 외피의 기초물성을 평가하였다. 또한, 내화성능이 우수하고 경량인 Nano size의 복합소재를 이용한 충전재의 압축강도, 휨강도, 인장강도를 평가하여 복합섬유패널의 성능에 대한 기초 연구를 수행하였다.

표준화재 재하조건 콘크리트 중공슬래브의 피복두께에 따른 화재거동에 관한 실험적 연구 (An Experimental Study on the Fire Behavior of Concrete Void Slab under Standard Fire with Loading Condition)

  • 김흥열;김형준;조범연;여인환;권인규
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.64-72
    • /
    • 2011
  • 기존의 무량판 구조와 동일한 콘크리트 중공슬래브구조는 구조적 하중지지 성능이 불필요한 슬래브 단면상의 중앙부 콘크리트를 제거하여 슬래브의 자중을 줄이고 무량판 구조의 단점을 보완하여 장점을 극대화시킨 구조형식이다. 본 연구에서는 콘크리트 중공슬래브 공법의 실제 스팬길이인 7.5 m에서 슬래브 피복두께에 따른 화재거동 영향성 분석을 위하여 화재실험을 수행하였다. 하중조건은 고정하중과 적재하중을 고려하여 실험체에 등분포 조건으로 사전 재하하였으며, 표준화재조건으로 재하가열 실험을 수행하였다. 슬래브의 화재가열 노출면으로부터의 깊이별 온도변화와 처짐변형 특성을 측정하였으며, KS F 2257-1 평가기준에 의거하여 슬래브의 내화성능을 평가하였다. 실험결과 피복두께 50 mm를 확보할 경우, EPS 중공체로 제작한 실험체의 경우 약 2시간 정도의 내화성능을 확보할 수 있는 것으로 나타났다.