References
- Ministry of Land, Infrastructure and Transport, "Building Act", Gwachenon, Korea (2013).
- Ministry of Construction and Transportation, "Development of Fire Engineering Technique", Gwachenon, Korea (2002).
- I. K. Kwon, "Evaluation of Fire Resistance according to Load Ratio of Structural Steel Elements", Journal of Architectural Institute of Korea, Vol. 26, No. 4, pp 55-62 (2010).
- S. Y. Park, H. Y. Kim and K. P. Hong, "Analytic Study on the Fire Resistance of the Asymmetic H-Section Slim Flor Beam Concerning the Load Ratio", Journal of Architectural Institute of Korea, Vol. 26, No. 9, pp 55-62 (2010).
- S. B. Kim, S. K. Choi, C. N. Lee and S. S. Kim, "Study on the Fire Resistance Performance of the TSC Beam", Journal of Korean Steel Structure, Vol. 18, No. 1, pp. 113-122 (2006)
- Y. H. Him, S. D Kang, M. H. Oh, M. H. Kim and S. D. Kim, "Analytical Study on the Fire Resistance of iTECH Composite to Beam", Journal of Korean Steel Structure, Vol. 18, No. 5, pp. 655-664 (2006)
- G. M. Newman, "Fire Resistance of Slim Floor Beams", Journal of Constructional Steel Research, Vol. 33, pp. 87-100 (1995). https://doi.org/10.1016/0143-974X(94)00016-B
- Z. Ma and P. Makelainen, "Structural Behaviour of Composite Slim Floor Frames in Fire Conditions", Journal of Constructional Steel Research, Vol. 62, pp. 1282-1289 (2006). https://doi.org/10.1016/j.jcsr.2006.04.026
- T. C. H. Liu, M. K. Fahad and J. M. Davies, "Experimental Investigation of Behaviour of Axially Restrained Steel Beams in Fire", Journal of Constructional Steel Research, Vol. 58, pp. 1211-1230 (2002). https://doi.org/10.1016/S0143-974X(01)00062-1
- Y. Z. Yin and Y. C. Wang, "A Numerical Study of Large Deflection Behaviour of Restrained Steel Beams at Elevated Temperatures", Journal of Constructional Steel Research, Vol. 60, pp. 1029-1047 (2004). https://doi.org/10.1016/j.jcsr.2003.09.005
- I. K. Kwon, "An Analytic Study on Structural Stability according to Boundary Conditions and H-section Column Lengths made of An Ordinary Grade Structural Steels (SS 400) at High Temperatures", Journal of Korean Institute of Fire Science and Engineering, Vol. 28, No. 1, pp. 20-25 (2014). https://doi.org/10.7731/KIFSE.2014.28.1.020
- Swedish Institute of Steel Construction, "Fire Engineering Design of Steel Structures", Stockholm, Sweden (1976).
- D. G. Kim, C. K. Ma, J. C. Chung and J. J. Ju, "H Section Steel Structure Design", Seoul, Korea (2003).
- Korean Standard Association, KS F 2257-1, "Methods of Fire Resistance Test for Elements of Building Construction-General Requirements", Seoul, Korea (2010).
- I. K. Kwon, "Development of Analytic Program for Calculation of Fire Resistant Performance on Steel Structures", Journal of the Regional Association of Architectural Institute of Korea, Vol. 11, No. 3, pp. 201-208 (2009).
- Research Institute of Science & Technology, "Technical Development of Fire Engineering Design for Steel Structure (I)" (2002).
Cited by
- Experimental Study on Behavior of H-Beam with End-plate Connection at High Temperature vol.30, pp.4, 2018, https://doi.org/10.7781/kjoss.2018.30.4.175