• Title/Summary/Keyword: 내진시험

Search Result 264, Processing Time 0.021 seconds

Seismic Analysis of the Reflective Metal Insulation for Thermal Shielding of Main Equipments of Nuclear Power Plants (원전 설비 열차폐를 위한 반사형 금속단열재의 내진 해석)

  • Kim, Seung-Hyeon;Rhee, Huinam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.166-172
    • /
    • 2016
  • This paper deals with the seismic qualification of the reflective metal insulation for thermal shielding that is installed on the outer surfaces of the main equipment of the primary coolant system of a nuclear power plant. A small-scale model of the reactor pressure vessel, which has equivalent dynamic characteristics, was designed to be tested in domestic seismic testing facilities in the future. In this study, seismic analysis of the small-scale model installed with metal insulation was performed using equivalent static analysis and response spectrum analysis. The required Response Spectrum for main equipment of the primary coolant system of APR-1400 plant were considered to establish the enveloping response spectrum, which was applied to the seismic analysis model. The results from two seismic analysis methods were compared to show the structural adequacy of the metal insulator design against a safe shutdown earthquake. This study will form the basis for the seismic testing to support the seismic qualification of the reflective metal insulator.

Modal Identification and Nonlinearity Assessment of Electric Cabinet for Improvement of Basic Fragility Variables (취약도변수의 개선을 위한 전기 캐빈비넷의 동특성 및 비선형성 평가)

  • 조양희;조성국;박형기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.83-91
    • /
    • 2000
  • 합리적인 기기의 활률론적 지진위험도 평가를 위해서는 모델의 동특성에 대한 보다 현실적인 정보가 제공되어야 한다. 이 연구에서는 심한 비선형 동적 거동을 보일 것으로 예상되는 철제 전기 캐비넷의 동특성 시험결과 및 분석 절차를 제시하였다. 특히, 이 연구에서는 가진 강도의 크기에 따른 동특성의 비선형 집중분석하고, 그 비선형성의 원인을 고찰하였다. 시험 결과 및 이 논문에 제시된 분석 절차를 이용하여 시험체의 동특성이 효과적으로 도출될 수 있으며, 대상 시험체는 가진 강도에 따라 심한 비선형 거동을 함을 입증하였다. 비선형성의 원인은 일반적인 재료 비선형이라기 보다는 각 부품들의 마찰력과 기하학적인 비선형성에 기인함을 발견하였다. 또한, 캐비넷 형식의 기긱에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다. 또한, 캐비넷 형식의 기기에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다.

  • PDF

Seimic Qualification of Safety Related Reactor Control Panel (원자로 안전관련 정지반의 내진검증)

  • Yoo, Bong;Ahn, Gyu-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.129-133
    • /
    • 1990
  • 본 논문에서는 원자로정지반의 실제제작을 위한 예비단계로서 예비설계된 정지반의 전산모델을 이용하여 내진해석을 수행하였으며 이는 내진설계자료 및 내진시험에 대한 검증자료로 활용될 수 있을 것이다.

  • PDF

콘크리트 확장형 앵커의 동적검증

  • 김상윤;윤철호;최강룡
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.339-345
    • /
    • 1996
  • 배관 및 기기 등의 지지부 정착에 사용되는 확장형 앵커는 여러 종류의 진동하중을 받게 되므로 그러한 하중에 대한 동적저항능력이 시험에 의하여 확인되어야 한다. 확장형 앵커의 동적시험 요건이 ASTM E488에 기술되어 있으나 내진시험 입력, 피로전단시험 입력 등 일부 요건이 구체적으로 명시되어 있지 않아 시험기관에 따라 시험조건이 자의적으로 결정될 수 있다. 따라서, 본고에서는 코드 시험요건이 구체적이지 못한 사항을 조사하여 적정 요구수준을 제시하였다. 또한, 국내에서 수행된 동적시험내용 검토결과, 현행 동적설계방안의 일부보완이 필요함을 확인하였다.

  • PDF

Study of Structural Stability and Seismic Performances of 4-Way Sway Prevention Brace (4방향흔들림방지버팀대의 구조 안정성 및 내진 성능 연구)

  • O, Soo Un;Lee, Hang Jun;Choa, Sung Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.646-659
    • /
    • 2022
  • Purpose: In this study, we developed a 4-way sway prevention brace that efficiently reduces the installation area and has excellent stability and seismic performance compared to the conventionl sway prevention brace used in existing firefighting facilities. The performance and reliability of the developed 4-way way prevention brace were analyzed by the tensile, compression tests and seismic tests. Method: As the static test, 4-way sway prevention braces were installed on the horizontal and vertical pipes to perform the tensile and compression tests based on the KFI certification standard and the maximum movement was measured at the rated load. As a dynamic test, 4-way sway prevention braces were installed in the pipes filled with water, and the test response spectrum to the input excitation wave were measured through the acceleration sensors. After the seismic tests, separation, failure, and local deformation of the pipes, and 4-way sway prevention braces were not observed. Result: The results of the tensile and compression tests indicated that the maximum movement of the pipe during tension and compression was 50% to 70% or less compared to the certification values, indicating that the performances of the 4-way sway prevention braces were very excellent. The results of the the seismic tests indicated that the test response spectrum of the 4-way sway prevention braces is within the required response spectrum. Conclusion: In this study, it was found that the 4-way sway prevention braces satisfied the KFI certification standard and were superior compared to the existing sway prevention brace in terms of the stability, cost, and installation area.

Development of a Seismic Test Method for Fire Protecting Components by Equivalent Linear Analysis Theory (등가선형해석이론에 의한 소방설비 구성품의 Lab scale 내진성능평가기법 개발)

  • Kwark, Ji-Hyun;Yoon, Jong-Ku
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.46-51
    • /
    • 2013
  • In this study a lab scale seismic test method which is able to evaluate seismic resistant performance of the fire protecting components in case of earthquake was developed. This seismic test consists of equivalent accelerating and temporary accelerating. The former is to search for resonance frequency and the latter is to simulate vibrating by earthquake with intensive magnitude. The frequency and displacement accelerated to the components was decided by maximum acceleration of gravity, and whether or not they could maintain function was tried to be confirmed. This test method is expected as an effective one for evaluating seismic resistant performance for the fire protecting components.

Seismic Capacity Evaluation of Wood Structure Using Soil-Wall Test (흙벽 실험에 의한 목조 건축물의 내진성능 평가)

  • Kim, Hye-Won;Yang, Won-Jik;Oh, Sang-Hoon;Lee, Jung-Han;Park, Byung-Cheol;Yi, Waon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.409-412
    • /
    • 2010
  • 본 연구는 목조 건축물 흙벽의 수평가력실험 결과를 이용한 내진성능 평가를 목적으로 한다. 흙벽 실험시험체는 기둥과 보 결합방식에 따라 민도리, 초익공, 장여방식으로 분류되고 벽체 형태에 따라 창문, 문, 전면 벽체, 인방 부재수 등으로 계획을 하였다. 12개 흙벽 시험체의 가력결과, 전면 벽체 시험체는 변위각 1/30에서 가장 큰 강성 저하율을 보이며 중인방과 수직재가 있는 벽체는 에너지 소산능력이 가장 큰 것으로 나타났다. 기존 연구로부터 목조 건축물 항복점 평가방법을 이용하여 등가탄소성 곡선으로 나타낸 전단내력은 민도리방식이 프레임과 전면 벽체일 경우 가장 크고, 전단응력은 벽체 개구율에 따라 다르게 나타났다. 실험결과로부터 적용 대상 건축물의 X, Y방향 구조성능을 산출하고 구조내진지표와 역량스펙트럼을 이용하여 내진성능 평가를 실시한 결과, 대상 목조 건축물은 내진성이 있음으로 평가되었다.

  • PDF

Study on Seismic Analysis and Test for Seismic Qualification of 245kV GIS (245kV 가스절연개폐장치의 내진성능 실증을 위한 시험 및 해석)

  • Kim, Yu-Gyeong;Kwon, Tae-Hoon;Jeong, Yeong-Jin;Kim, Hong-Tae;Kim, Young-Joong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.715-722
    • /
    • 2013
  • Gas insulated switchgear is large-sized electric equipment for providing a reliable supply of electric power. Recently, seismic tests of electric equipment using a shaking table have been mandated because seismic performance has become an increasingly important issue. However, basic analysis methods continue to be used because some electric equipment is too large for shaking table facilities. Thus, a reliable analysis method should be developed for large-scale electric equipment. This study aims to evaluate the seismic qualification of a 245kV GIS in accordance with IEEE-693 and to validate the analysis method by comparing it with test results. Both the test and the analysis showed that the 245kV GIS has proper seismic safety. Furthermore, the differences between the analysis and the test results are less than 10% for an accurately given mass, stiffness, and input acceleration. It is expected that this study can be used for the seismic qualification of large-scale electrical structures.

Bending performance evaluation of high strength and seismic purpose reinforcing bars (고강도 및 내진용 철근의 굽힘성능 평가)

  • Kim, Hee-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.492-498
    • /
    • 2017
  • This study examined the bending performance of high strength and seismic purpose reinforcing bars experimentally with various parameters. For the experimental approach on the bending performance, the specimens were prepared with parameters, such as steel grades, diameters of reinforcing bars, and bending angles of reinforcing bars. Tensile strength tests on the reinforcing bars, the bending tests and re-bending tests, and the second tensile strength tests on the re-bended reinforcing bars were conducted. According to the test results on high strength and seismic purpose reinforcing bars, defects did not appear when the yield strength of the reinforcing bar was 500 MPa or less and the diameter was D13 or less, even when the first bending process was performed with a $135^{\circ}$ bending angle and a $2d_b$ inner radius. The bending performance decreased asthe strength and diameter of the reinforcing bars was increased. In addition, there was no significant difference between the general reinforcing bars and seismic purpose-reinforcing bars.

마이크로프로세서를 사용한 고리원자력발전소용 SSILS의 설계

  • 하달규;김창구;박기현;전성즙;문성득
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.277-283
    • /
    • 1997
  • 본 논문에서는 고리원자력발전소용 SSILS(Solid State Interposing Logic System)을 소프트웨어의 건전성을 확보하면서 마이크로프로세서로 설계해 가는 과정을 기술하였다 설계 제작된 시제품은 IEEE Std 344-1975에 따라 내진시험을 하였고 IEEE Std. 323-1983에 따라 환경시험을 필하였다. 그리고 소프트웨어의 건전성은 자체적으로 확인하였다.

  • PDF