• Title/Summary/Keyword: 내진설계 적합성

Search Result 48, Processing Time 0.032 seconds

Generation of Korean artificial earthquakes for Fragility curve (손상도 곡선 작성을 위한 한국형 인공지진의 생성)

  • Nam, Youngyoon;Lee, Jongheon
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.3
    • /
    • pp.406-412
    • /
    • 2015
  • Recently, frequent earthquakes can cause serious damage to the bridge. So newly constructed bridge is considered earthquake resistant design, and for the existing old bridge evaluation of damage state is needed. In this paper, replacement of US-artificial earthquakes which are used for the construction of fragility curve for evaluating damage state to Korean artificial earthquakes to meet the Korean specifications is studied. For the generation of artificial earthquakes, the fragility curves are constructed for the PGA, for the cases of having isolated bearing and not having that.

The Study on the Placements of Brace Members Using Optimum Seismic Design of Steel Frames (강골조 구조물의 내진 최적설계에 의한 브레이스 부재 배치에 관한 연구)

  • Kim, Ki-Wook;Park, Moon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.111-119
    • /
    • 2005
  • This study presents continuous and discrete optimum design algorithm and computer programs for unbraced and braced steel frame structures under earthquake loads. The program, which is avaliable to perform structural analysis and optimum design, continuous and discrete, simultaneously is developed. And the program adopts various braced types, Untraced, Z-braced(V), Z-braced(inverse-V), X-braced(A), X-braced(B), X-braced(C) and K-braced, in steel structures with static loads and seismic effects. The objectives in this optimization are to minimize the total weight of steel, and design variables, based on the ultimate strength requirements of AISC-ASD specifications, the serviceability requirements and allowable story drift requirements of ATC-3-06, and various constraints. The purpose is to present proper braced type for seismic effects by comparing and analysing results of various cases.

Generation of Artificial Time History Earthquake Record Family using the Least Squares Fitting Method (최소오차 최적합화 방법에 의한 인공 시간이력 지진기록군의 생성)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.31-38
    • /
    • 2008
  • Recently the necessity of time history analyses is increasing for the seismic analyses of a structure, and the seismic design provisions of IBC2003, ASCE and KBC2005 require the use of a minimum of seven earthquake records for the time history analyses. Earthquake records for the time history analyses could be selected from the database of the field-measured earthquake records having similar site conditions with the designed site, or from simulated sites satisfying the design spectrum. However, in this study seven earthquake records were generated using 50 earthquake records, classified as records measured at the rock, in the database of the Pacific Earthquake Research Center (PEER). Seven earthquake records were first selected by the least squares fitting method comparing the scaling factored response spectra with the specified design spectrum, and a family of seven artificial time history earthquake records was ultimately generated by multiplying scaling factors, which were calculated by the least squares fitting method and the SRSS averaging method, to the corresponding selected earthquake records.

Seismic Performance Assessment of RC Pier Walls under Cyclic Out-of-plane Loading (면외방향으로 반복하중을 받는 철근콘크리트 벽식 교각의 내진성능평가)

  • Kim, Tae-Hoon;Kim, Young-Jin;Shin, Hyun-Mock
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.73-83
    • /
    • 2006
  • The purpose of this study is to investigate the seismic behavior of reinforced concrete pier walls under cyclic out-of-plane loading and to develop improved seismic design criteria. The accuracy and objectivity of the assessment process can be enhanced by using a sophisticated nonlinear finite element analysis program. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. A 4-node flat shell element with drilling rotational stiffness is used for spatial discretization. The layered approach is used to discretize the behavior of concrete and reinforcement through the thickness. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. The method is verified a useful tool to assess the seismic performance of reinforced concrete pier walls subjected to cyclic out-of-plane load through comparing with reliable experimental results.

Seismic Performance Evaluation of Staggered Truss System by the Shape of Truss (트러스 형태에 따른 스태거드트러스 골조시스템의 내진성능 평가)

  • Hong, Yoon-Soo;Yu, Eun-Jong;Rha, Chang-Soon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.397-404
    • /
    • 2017
  • The purpose of this study is to evaluate the seismic performance of Staggered Truss Frame(STF) system while changing a shape of truss. The model of this project is a office building of ten floors with Pratt, Howe, Warren, K and Vierendeel truss system applied on each model. Next step is to select the section of elements which satisfy the highest demand capacity ratio by structure design considering gravity load, earthquake load and wind load and then calculate natural period, base shear and story drifts. On the basis of these values, Capacity Spectrum Method(CSM) shows the plastic behavior of STF system such as performance point of Design Earthquake(DE) and Maximum Considered Earthquake(MCE), yield state, plastic hinge etc. to be compared with other truss systems. As a result, Vierendeel STF system especially was found to have the highest strength and stiffness to the corresponding earthquake and all the models for each truss shape fulfilled the target performance level.

Nonlinear Response Spectra of Artificial Earthquake Waves Compatible with Design Spectrum (설계용 스펙트럼에 적합한 인공지진파에 의한 비선형 응답 특성의 분석)

  • Jun, Dae-Han;Kang, Pyeong-Doo;Kim, Jae-Ung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.63-71
    • /
    • 2006
  • In seismic response analysis of building structures, the input ground accelerations have considerable effect on the nonlinear response characteristics of structures. The characteristics of soil and the locality of the site where those ground motions were recorded affect on the contents of earthquake waves. Therefore, it is difficult to select appropriate input ground motions for seismic response analysis. This study describes a generation of artificial earthquake wave compatible with seismic design spectrum, and also evaluates the nonlinear response spectra by the simulated earthquake motions. The artificial earthquake wave are generated according to the previously recorded earthquake waves in past earthquake events. The artificial wave have identical phase angles to the recorded earthquake wave, and their overall response spectra are compatible with seismic design spectrum with 5% critical viscous damping. Each simulated earthquake wave has a identical phase angles to the original recorded ground acceleration, and match to design spectra in the range of period from 0.02 to 10.0 seconds. The seismic response analysis is performed to examine the nonlinear response characteristics of SDOF system subjected to the simulated earthquake waves. It was concluded that the artificial earthquake waves simulated in this paper are applicable as input ground motions for a seismic response analysis of building structures.

The optimum damping retrofit for cabinet structures of NPP by μ-GA (μ-GA를 이용한 원전 캐비닛구조물의 최적감쇠보강)

  • Lee, Gye-Hee;Ha, Dong-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.1-7
    • /
    • 2005
  • The optimal seismic retrofitting of NPP(Nuclear Power Plant) cabinet structures that contain seismic category 1 relays was studied in this paper. During earthquake event, the failure modes of relays are not appeared in form of structural failure, but are appeared in form of contact chatter of relay. Therefore, the retrofitting of cabinet has to be aimed at the reducing of the structural response, such as acceleration. In this study, the optimal characteristic values of dampers were searched by ${\mu}$-GA (micro-Genetic Algorithm) scheme for several installation patterns. To keep accuracy and efficiency of analysis, the structural models of cabinet were considered as a frame structure. The responses of structure were obtained inform of acceleration response spectra derived from the results of nonlinear time history analysis including damping nonlinearity. The objective function of the optimum procedure was constructed based on the maximum ratio of maximum spectral value and target GERS (General Equipment Ruggedness Spectra). The results show the good improvements of fitness for adequate retrofitting pattern. Especially, the improvements of fitness were remarkable when the values of damping exponents are low.

A Study on the Deduction of performance Point of Nonseismically Designed Reinforced Concrete Apartment (비내진 설계된 철근콘크리트 아파트의 성능점 도출에 관한 연구)

  • Kwon, Ki-Hyuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.85-93
    • /
    • 2005
  • It has been commonly assumed that during the 21st century, the korean peninsula may suffer huge earthquake damage to people, society, and economic system. The recent report of "Seoul Earthquake Response model development" conducted by the city of Seoul indicated that a magnitude 6.3 earthquake possibly hit Seoul, the capital of Korea. However, due to the insufficient amount of study on seismic performance of structures reflecting the various types of element peculiar to Korea application of the currently available earthquake damage evaluation methods has limitations. In order to conduct various studies on seismic hazards that are suitable for the actual conditions in Korea, therefore, fundamental studies first have to be properly conducted. The purpose of this study is to serve as the basis of establishing a reliable earthquake damage estimation system, and to provide essential data for the seismic damage evaluation of nonseismically reinforced concrete apartment structures. In this study, a standard type of nonseismically reinforced concrete apartments has been determined based on an extensive survey and careful review of such structures in Korea, and their performance level on seismic loading has been estimated.

Effects of Slope Location on the Boundary Condition in the 1g Shaking Table Test (1g 진동대시험에서 사면의 위치에 따른 경계조건 영향평가)

  • Jeong, Sugeun;Jin, Yong;Kim, Daeheyon
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.535-545
    • /
    • 2022
  • Improving the stability of the ground in seismic design requires an understanding of the dynamic behavior of the ground under seismic loads. The shaking table test is an important methodology to provide this understanding. This study aimed to assess the influence on boundary conditions, as they are among the most important factors affecting the test. This was achieved by testing the influence of boundary conditions on the seismic responses of model slopes at different locations in the testing apparatus. A model slope was fabricated at different locations in a laminar shear box, and the influence of the boundary conditions was then measured. Each model slope was created at 100, 50, and 25 cm from the soil wall, and sine wave seismic loads of the same size were inputted. The results confirmed that the acceleration was amplified by the influence of the boundary in the case of the slope being located 25 cm from the boundary, whereas the influence of the boundary conditions decreased when the slope was located at 50~100 cm.

Comparison of Wind Load Provisions Based on the Wind Buckling Behaviors of Plant Tank (플랜트 탱크의 좌굴 거동에 근거한 풍하중 설계기준 비교 연구)

  • Bae, Doobyong;Park, Il Gyu;Park, Jang Ho;Oh, Chang Kook
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.203-211
    • /
    • 2016
  • There are no consistent wind load provisions to design the plant tank in Korea. To suggest the appropriate design wind load, five kinds of specifications including KS B 6283, API 650, ASCE 7-10, EN 1991-1-4 are compared. To evaluate the adequacy of wind load specification in each code first, pressure coefficients were calculated in each code and compared with the results of wind tunnel test. Finite element analyses using linear bifurcation analysis were performed with the parameter of h/d and f/d (h : height of cylinderical part of tank, f : roof heigh, d : diameter of tank). By analyzing the results, appropriate wind load criteria which reflects the real wind actions and easy to apply will be suggested.