• Title/Summary/Keyword: 내진설계 기준

Search Result 434, Processing Time 0.031 seconds

Earthquake Resistant Design Methods on the Slopes (지진을 고려한 비탈면 설계 방안)

  • Kim, Ju-Hyong;Lee, Yong-Su;Cho, Sam-Deok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.1 s.16
    • /
    • pp.23-32
    • /
    • 2005
  • A significant development has been made on earthquake resistant designs on many structures since the Korean government has begun modern earthquake hazard reduction programs after recognizing potential disastrous consequences of seismic events following the Kobe earthquake in 1995. However, some structures such as slope structures still haven't get ready for their own seismic design guidelines in Korea. Therefore, only a few organizations of Korea adopt seismic design for slopes relying on designers' judgments at present. This paper introduces domestic and foreign research activities on seismic slope stability and an idea of Korean earthquake resistant design method for slopes including alternatives of earthquake resistant design application according to designers' judgment considering construction budget, importance, restoration and so on. Afterwards, seismic data accumulation on slope stability of Korea is necessary to induce a more definite Korean earthquake resistant design method.

Comparative Study on Seismic Design of Soil-Reinforced Segmental Retaining Walls (블록식 보강토 옹벽의 내진설계에 관한 비교연구)

  • 유충식
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.51-61
    • /
    • 2000
  • This paper reviews fundamentals of a pseudo-static seismic design/analysis method for soil-reinforced segmental retaining walls. A comparative study on NCMA and FHWA seismic design guidelines, which are one of the most well known design guidelines for mechanically stabilized earth walls, was also performed. The results demonstrate that there exist significant discrepancies in the results of external stability analysis despite the same calculation model used in the two guidelines, due primarily to different seismic coefficient selection criteria. It is also demonstrated that the internal stability calculation model for NCMA guideline tends to yield larger seismic reinforcement force in the shallower reinforcement layers, resulting in an increased number of reinforcement layers at the top of reinforced wall and increased reinforcement lengths to ensure adequate anchorage capacity. The internal stability calculation model adopted by FHWA guideline, however, leads to redistribution of dynamic force to the lower reinforcement layers and thus results n an opposite trend of NCMA guideline. Findings from this study clearly demonstrate a need for more in-depth studies to develop a generally acceptable design/analysis method.

  • PDF

Use of Shakedown Analysis Technique in Optimum Seismic Design of Moment-Resisting Steel Structures (모멘트 - 저항 철골구조물의 최적내진설계에 있어서의 Shakedown 해석기법의 응용)

  • 이한선
    • Computational Structural Engineering
    • /
    • v.2 no.4
    • /
    • pp.99-109
    • /
    • 1989
  • Through a series of analyses of specific structures it is shown that incremental collapse may be the critical design criterion and that shakedown analysis can be used as a design tool. Using shakedown analysis technique, a nonlinear structural optimization program has been developed. This incorporates: (i) design constraints on elastic stresses and deflections: (ii) constraints for the prevention of incremental collapse and soft story failure: and (iii) the constraint on the fundamental period of structure. A five-step design procedure is proposed by using the program to obtain the optimum design that satisfies all the requirements of comprehensive earthquake-resistant design.

  • PDF

The Study on the Necessity of Seismic Design for Fire Protection System and the Establishment of Standard (소방시설 내진설계의 필요성과 기준정비에 관한 연구)

  • Shin, Yi-Chul;Han, Byung-Chan;Park, Sun-Gyu;Lee, Hyun-Jin;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.6-12
    • /
    • 2009
  • In this paper, provisions related with the seismic design and equipments of fire protection system are being considered. The provisions from various international codes on seismic design fire protection system were reviewed. The codes, reviewed are, Japanese code, NFPA guideline and Korean Code. It is noted that all the codes excepted to Korean Code consider earthquake effect to evaluate seismic forces and behaviors. But, korean provision are not covered in seismic response in all. A brief description on limitations in Korean Code is also presented.

Comparative Study on the Quantity Economic Analysis of Apartment Frames Using SDS Result of Dynamic Centrifuge Test at Pile Foundation (말뚝기초의 동적실험결과를 사용한 아파트 골조의 경제성 비교분석)

  • Kim, Sang-Yeon;Park, Jong-Bae;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.6 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • Site coefficient and amplification factor of current domestic Seismic Design Code based on American Seismic Code, have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. By previous studies, the measured spectral acceleration of the result of dynamic centrifugal test and analysis was smaller than the design spectral acceleration for the period over 1.5 sec. Accordingly, in this study structural analysis and design using dynamic centrifugal test result for pile foundation were achieved, and the quantity of concrete and reinforcement of wall frame was compared with each other. Comparison results of cost using KBC the design spectral acceleration of SC, SD site and SDS, the quantity of reinforcement using SDS for SD site was 17~23% smaller than using the design code SD site.

Example of the Structural Design with Applied SNiP codes in the Commonwealth of Independent States (CIS) (CIS 국가 내진 설계 방법과 SNiP Code를 적용한 주거시설 구조설계 사례)

  • Lee, Dong-Woo;Kwak, Chul-Seung;Jeong, Hoon-Sik
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.232-237
    • /
    • 2008
  • In the Commonwealth of Independent States (CIS), the international organization, or alliance, consisting of eleven former Soviet Republics, their own regulation and standard, codes of the building are based on SNiP issued from the Russia. The SNiP for the seismicity is based on Kazakhstan codes where earthquake is very strong. After their independence, Seismic codes for Former Soviet Republics have been developed in their own accord. The building subjected by more than certain magnitude should be followed by TU as well as SNiP. In this paper, the residential complex project where seismic stability is considered from schematic design will be introduced. In this project, Local analysis program and method for arrangement of bar was applied. In the structural drawings, Korean and Local methods was compromised.

  • PDF

Inelastic Analysis of Steel Frame Structures with Viscoelastic Damper (점탄성 감쇠기가 설치된 철골조 건물의 비탄성 해석)

  • 김진구;최현훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.271-278
    • /
    • 2000
  • In this study the effect and applicability of viscoelastic dampers on the seismic reinforcement of steel framed structures are investigated in the context of the performance based design approach. The effect of the damper on dissipating the input seismic energy was investigated with a single degree of freedom system. For analysis models a five-story steel frame subjected to gravity load, a ten-story and twenty-story structure subjected to gravity and wind load were designed. The code-specified design spectrums were constructed for each soil type and performance objective, and artificial ground excitation records to be used in the nonlinear time history analysis were generated based on the design spectrums. Inter-story drift was adopted as the primary performance criterion. According to the analysis results, all model structures turned out to satisfy the performance level for most of the soil conditions except for the soft soil(operational level). It was also found that the seismic performance could be greatly enhanced, and the structures were led to behave elastically by installing viscoelastic dampers on appropriate locations.

  • PDF

A Study on the Equivalent Static Analysis of Unreinforced Masonry Buildings (비보강 조적조 건물의 등가 정적 해석에 관한 연구)

  • 정상훈;김관중;김희철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.1-10
    • /
    • 2000
  • 우리 나라의 주거 건물의 많은 부분을 차지하는 조적조 건물은 저층이므로 내진 설계에 대한 지침이 마련되어 있지 않다. 그러나 조적조 건물의 경우 저층이라 하더라도 구조특성상 수평하중에 대한 저항능력이 매우 약하므로 내진 설계에 대한 기준이 요구된다. 일반적으로 내진설계 시 동적 해석을 수행하면 많은 시간이 소모되므로 실무자들에게 등가정적해석법을 제시하여 내진설계 시 편의를 제공하고 있다. 그러나 저층 조적조 건물은 일반적인 건물과는 거동 특성이 다르므로 저층 조적조 건물에 적용할 수 있는 해석법을 제시하고자 한다. 본 논문에서는 개구부의 비율에 따른 조적벽의 연성도, 강도 및 고유주기를 구하여 반응수정계수와 고유주기를 비교하여 우리 나라의 조적조 건물에 적합한 반응수정계수와 고유주기 산정식을 제안하였다.

  • PDF