• Title/Summary/Keyword: 내사위

Search Result 43, Processing Time 0.024 seconds

The Study on The Property of the Phoria and Asthenopia Inducing Factor in Adults in Jeon-Buk Area (전북지역 성인의 사위특성과 안정피로 유발인자에 관한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.101-106
    • /
    • 2018
  • We examined refractive error, the corrected visual acuity, phoria and fusional reserve of 114 healthy myopes and hyperopia who had no strabismus, no ocular and physical diseases. We evaluated the occurrence of asthenopia according to phoria and fusional reserve. 41 out of 114 subjects which exophoria was 69% and esophoria was 5.5%, orthophoria was 26% made a complaint against asthenopia. The subjects who had exophoria of $0-6{\Delta}$ in the range of normal state was 61.4%, while the subjects who had exophoria of $7{\Delta}$ or more in the range of abnormal state was 38.6%. Reducing fusional reserve was associated with increasing phoria. The fusional reserve twice or more than phoria were 27.2%, and twice or under were 72.8%. Futhermore, AC/A ratio for heterophoria was found from 1.0 to 12.6 and its relationship to asthenopia of phoria could not be determined.

Correlation of Near Stereoacuity and Phoria, and Refractive Error (근거리 입체시와 사위 및 굴절이상의 상관관계)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2015
  • Purpose: This study was investigated the relationship between the male and female of near stereoacuity and phoria, and was examined the correlations between near stereoacuity and phoria and refractive error. Methods: Adult 83 (male 36, female 47, mean age $21.09{\pm}1.74$(19~29) years old) target was examined after full correction of refractive error. Near stereoacuity was measured by using Titmus-fly Stereotest(Stereo Optical Co., Inc., Chicago, IL, USA), and RANDOT Stereotest (Stereo Optical Co., Inc., Chicago, IL, USA), phoria was measured by using modified torrington method, at distance 40 cm. Results: In near stereoacuity, male was better good than female, and there was no difference between male and female (p>0.05). In near phoria, female was more higher than male, and there was a significant difference between male and female (p<0.05). Near stereoacuity by Titmus-fly test and Randot test result respectively was $262.17{\pm}562.43$ sec (second of arc) $243.08{\pm}68.04$ sec in esophoria, $148.42{\pm}269.54$ sec, $107.40{\pm}263.74$ sec in orthophoria, $113.94{\pm}152.46$ sec, $79.70{\pm}136.83$ sec in exophoria, there was a no difference between three phoria groups (p>0.05), and was a high correlation between phoria and near stereoacity(r=0.68). In addition, near stereoacuity in the refractive error respectively was $80.00{\pm}571.43$ sec, $68.75{\pm}36.82$ sec in myopia, $133.57{\pm}224.15$ sec, $93.14{\pm}214.95$ sec in hyperopia, $511.20{\pm}855.00$ sec, $511.4{\pm}855.60$ sec, there was a significant difference between three phoria groups (p<0.05). when was classfiied near stersoacuity into degree of refractive error, near stersoacuity was best in emmetropia, and was reduced when refractive error was highest in high degree myopia, and hyperopia. Conclusions: Titmus-fly Stereotest and RANDOT Stereotest result, near stereoacuity of adults, when esophoria and high degree refractive error, was reduced, there was a relationship between near stereoacuity with phoria, and refractive error. In this both stereotests if was bad when near stereoacuity can expect a phoria and refractive error.

Measurement of the Phoria for Korean male and female adults by Maddox rod method (한국인 성인 남녀의 사위량측정)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.77-84
    • /
    • 1996
  • As the results of phoria measurement of Korean adults for 106 males and 55 females, the elevens (6.8%) are orthophoria, the nineties (55.9%) are esophoria and the fifty fives (34.2%) are exophoria respectively. Also the thirty threes (20.4%) are right hyperphoria against the left eye and the thirty eights (23.6%) are left hyperphoria against the right eye. Horizontal phoria is below $10{\Delta}$ mostly and vertical phoria is below $5{\Delta}$.

  • PDF

A Study and Analysis of Accommodative Convergence/Accommodation Ratio by Measuring Methods (측정방법에 따른 AC/A비의 조사 분석)

  • Park, Sang-Jae;Kwak, Hyung-Bin;Lee, Se-Hee;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.117-123
    • /
    • 2013
  • Purpose: The aim of this study was to propose effective data for the clinical examinations of binocular vision by comparative analysis of measuring the near horizontal phoria according to accommodative stimulations. Methods: It carried out near horizontal phorias, targeting 104 college students (50 males and 54 females) aged between 19 and 24 ($20.27{\pm}1.31$). It made a comparative analysis of changes in near horizontal phoria according to accommodative stimulations by using the von Graefe, Maddox rod and the Howell phoria methods respectively. We have also investigated the AC/A ratio in all phoria groups. Results: As the additional lenses were changed to the negative (-) diopter, the near horizontal phoria changed to the esodeviation. At this time, the rate of change in the section signifies the AC/A ratio, and the values were not consistent based on the evaluating methods or on each section. The AC/A ratio of the esophoria group appeared the largest value in all groups. As a result of analyzing AC/A ratio at the exophoria group using the von Graefe method, the AC/A ratio was $1.568{\pm}1.937$ ${\Delta}/D$ on the additional lenses +2.00 D and $2.527{\pm}2.253$ ${\Delta}/D$ on the additional lenses -1.00 D and at the esophoria group using the Howell phoria method, the AC/A ratio was $5.521{\pm}1.337$ ${\Delta}/D$, $5.593{\pm}1.623$ ${\Delta}/D$ on the additional lenses +2.00 D, +1.00 D and $4.687{\pm}1.643$ ${\Delta}/D$ on the additional lenses -2.00 D. These were significant differences statistically. Conclusions: In the exophoria group, when the (-) lenses were added, the averages of the AC/A ratio were shown to be high but in the esophoria group, when the (+) lenses were added, the of AC/A ratio was high.

Subjective Visuoperception to Vertical Yoked Prisms (수직동향프리즘의 자각적 시감각에 관한 연구)

  • Kim, Jae-Do;Kim, Dae-Hyun;Lee, Ik-Han;Kim, Bong-Whan;Kim, Young-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.95-99
    • /
    • 2008
  • Purpose: Even refractive error is perfectly corrected by glasses power, the glasses wearer can feel imbalance and uncomfortable by prism effects. The purpose of this study was to investigate subjective imbalance to vertical yoked prism in visually normal subjects. Methods: Visually normal 37 subjects (aged 20 to 31 y) were fully corrected by soft contact lens and worn vertical yoked prism, base up and base down 1, 2, 4, 6, 8 prism diopter(pd) at random order. A rating scale questionnaire was administered to assess quantitatively subjective imbalance to the yoked prism. The near phoria tests were done using Howell-Kim phoria card at 40 cm distance. Results: For the subjective response of imbalance, base up yoked prism was higher than base down yoked prism (t-test: t=4.67, p=0.00) in over 2 prism diopters. The frequency of subjects who feel imbalance by base up vertical yoked prism is higher for near esophoric group than for exophoric group. Conclusions: To reduce subjective imbalance caused by glasses such as dizzy, it needs to make the minimum prism effect, and base down yoked prism is more effective than base up yoked prism in prism effects.

  • PDF

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

The Effects of Visual Training on Binocular Anomalies (양안시 기능 이상의 시훈련(Visual Training)의 효과)

  • Kim, In-Suk;Hong, Dong-Gyun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.53-61
    • /
    • 2005
  • In this study, we measured Near Point of Convergence(N.P.C) tests, Phoria tests using Von Grafe method and relative convergence tests on 138 men and 162 women, so a total of 300 subjects aged between 8~45 to examine the improvement of the fusion vergence through visual training and obtained as follows. 1. According to the results, the near point of convergence of 57 (19%) subjects were shorter than 7cm, and 243 (81%) were 7cm or longer, having a problem in convergence. After visual training, the number of subjects have the value shorter than 7 cm increased from 57 to 111 (37%), and the number of those have the value 7cm or longer decreased significantly form 243 to 189 (63%). 2. The results of the measure of lateral Phoria at far distance by Von Grafe method showed orthophoria 18 (6%), exophoria 198 (66%), esophoria 84 (28%). After phoria test, we examined the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.l, B.O card. 3. The results of the measure of lateral Phoria at near distance by Von Grafe method showed orthophoria 6 (2%), exophoria 222 (74%), esophoria 72 (24%). After phoria test, we examine the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.I, B.O card.

  • PDF

Study on the Influence of LASIK on Binocular Change (양안시 변화에 대한 라식수술의 영향에 관한 연구)

  • Lee, Ki-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.267-273
    • /
    • 2006
  • For this study, we measured heterophoria, Calculated AC/A, Gradient AC/A of pre & post LASIK operation. In case of heterophoria, the results showed that orthophoria 2.78% decreased, exophoria 2.78% increased on pre & post op distance phoria and exophoria 5.55% increased, esophoria 5.55% decreased on pre & post op near phoria. In case of AC/A, Calculated AC/A significantly decreased as 0.36 at AC/A and accommodation decreased as 1.25D (p<0.05). It showed that Gradient AC/A decreased 0.34 and PC/A increased 0.09 but they didn't show significant difference.

  • PDF

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens (착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화)

  • Choi, Hyun-Soo;Park, Sung-Jong;Lee, Seok-Ju;Jin, Moon-Seok;Jun, Jin;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.339-343
    • /
    • 2011
  • Purpose: In this study, we investigated changes of phoria based on varying the color and concentration of the color in lenses. Methods: We measured distance phoria for 39 students who aged 20 to 40 with different concentrated lenes - red, gray, brown and green lenses in concentration 20%, 50% and 80%, respectively. Results: Subjects were divided into three groups which were orthophoria, esophoria and exophoria. Orthophoria in all the color and concentration, there were a few of the esophoria. Esophoria of average 2.07${\Delta}$,B.O showed that a slight increase in all colors and concentration, especially in brown lenses showed the greatest increase. Exophoria of average 3.82${\Delta}$,B.I showed that a slight decrease in all colors and concentration, especially in green lenses showed to 2.95${\Delta}$,B.I to the greatest decrease. Different concentration in same color had no specific tendency regarding phoria. Conclusions: The phoria must be considered when selecting color of the lens because of phoria is changeable by color of the lens. It is expected to study the criteria that minimize the asthenopia.