• Title/Summary/Keyword: 내부손실

Search Result 810, Processing Time 0.038 seconds

The Effect of Laser Geometry and Material Parameters on the Single Mode Gain Difference in Quarter Wavelength Shifted DFB Laser above Threshold Current (문턱전류이상에서 구조 및 재료 변수들이 $\lambda$/4위상천이 DFB 레이저의 단일모드 이득차에 미치는 영향)

  • 이홍석;김홍국;김부균;이병호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.75-84
    • /
    • 1999
  • Systematic studies for the effect of the linewidth enhancement factor, the confinement factor, the internal loss and the cavity length on the single mode gain difference and the frequency detuning are performed for $\lambda$/4 phase shifted DFB lasers above threshold. The above threshold characteristics are mainly determined by the linewidth enhancement factor, not by the confinement factor or the parameter defined by the product of the linewidth enhancement factor and the confinement factor. The normalized internal loss defined by the product of the internal loss and the cavity length mainly determines the above threshold characteristics compared to that of the internal loss or the cavity length alone. The effect of the cavity length on threshold characteristics is larger than that of the internal loss in the case of the same normalized internal loss. The above threshold characteristics of quantum well lasers are more resistant to the variations of the confinement factor and the normalized internal loss than those of bulk lasers due to the small linewidth enhancement factor.

  • PDF

Effect of nonuniform perforation in the concentric resonator on the transmission loss and back pressure (동심관형 공명기 내부의 천공 요소의 불규칙한 배열이 전달손실 및 배압에 미치는 특성 연구)

  • ;Antoine Delaigue
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.515-519
    • /
    • 2002
  • 자동차 및 유체기계의 흡기계나 배기계에 사용되는 소음기의 음향성능은 전달손실로 기계성능은 배압으로 표현된다. 유체가 흐르는 관 사이의 임피던스 부정합을 이용하는 반사형 소음기의 경우, 내부 유로에 천공을 주어 음향감쇠를 시키거나 유동을 안정시키는 경우가 많다. 본 연구에서는 동심관형 공명기의 내부 관에 존재하는 천공의 분포 양상이 소음기의 전달손실과 배압에 미치는 영향을 실험을 통하여 고찰하였다. 내부관의 평균 천공율은 일정하지만 길이 방향을 따라서 천공율이 변하는 다섯가지의 공명기에 대한 실험을 수행하고, 성능에 미치는 영향을 살펴보았다. 전달손실은 천공요소의 임피던스 모델을 고려하여 예측한 결과와 비교하였고, 측정된 배압은 모의 해석 결과와 비교하였다. 분석 결과, 천공율이 점점 작아지는 분포나, 작았다가 커진후 다시 작아지는 형태의 분포를 가질 경우, 배압 측면에서 매우 유리하고, 음향 전달손실도 큰 차이가 없음을 밝혔다.

  • PDF

단주기 내부파에 의한 저주파 음파의 전파손실 변동 추정

  • 나영남
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.33-36
    • /
    • 1996
  • 해양에서 내부파 (internal wave)는 수직적으로 밀도가 크게 다른 두 층의 경계면에서 생성되는데, 일반적으로 경계면은 수온약층 (thermocline)에 해당된다. 본 연구에서는 간단한 단주기(하나의 주기만을 갖는)내부파를 가정하고 이 내부파에 의해서 야기될 수 있는 저주파 (100-400 HZ) 전파손실의 변동 정도를 모델링을 통해 추정하였다. 내부파의 파장은 1Km이고 진폭은 25m이며 수심 50-100m 사이에 존재하는 것으로 가정하였다. 전파손실 계산은 PE (parabolic equation) 기법을 도입한 모델을 이용하였다.수층의 두께는 2000m로 균일하고 퇴적층 및 기반암층의 두께는 각각 500m로 가정하였다. 모델링 결과 단주기 내부파의 1 파장이 진행하는 동안 고정된 수신 깊이별로 20km 거리에서 10 dB 이상의 큰 변동이 야기 될 수 있음을 확인하였다. 이는 내부파 내에서 큰 굴절을 변화로 인한 음파의 산란 때문으로 볼 수 있다. 실제 해양에서는 내부파가 단주기 파동 형태로 나타나기 보다는 여러 주기의 파동이 중첩되어 나타나므로 정확한 내부파 영향을 추정하기 위해서는 보다 실제에 가까운 내부파를 모델링할 필요가 있다.

  • PDF

An Analysis of Energy Loss with Variation of Square Manhole Profile (직사각형 맨홀의 구조 변화에 따른 에너지손실 분석)

  • Kim, Jung-Soo;Jang, Suk-Jin;Yoon, Young-Noh;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.537-541
    • /
    • 2007
  • 관거시설의 맨홀에서 수두손실이 과대해지면 관거의 통수능력이 저하되어 배수구역의 침수피해가 발생되고, 우수의 분출 시 맨홀 뚜껑이 유실되어 인명사고를 유발할 수도 있다. 특히 1990년대부터 국지성 집중호우에 의한 도심지역의 침수피해가 빈번히 발생하고 있는 현실을 감안할 때, 관거시설 내 맨홀에서의 수리적 에너지 손실에 대한 연구와 보다 구체적인 설계 기준의 제시가 요구되고 있는 실정이다. 이러한 점을 고려할 때, 도시지역의 우수관거 시스템의 우수 배제 능력을 증가시켜 도심지의 침수를 방지하기 위한 관거시설의 적정 설계 기준이 필요하며, 합리적인 설계 기준을 제시하기 위하여 맨홀 내에서의 수두 손실을 분석할 필요가 있다. 그러므로 본 연구에서는 일반적으로 설치되어 있는 직사각형 맨홀의 현장조사와 설계기준을 조사하여 수리 실험 장치를 제작하였다. 선정된 실험조건인 맨홀의 내부형상 변화와 하수도 시설기준상의 맨홀 내의 단차규정에 따른 수리실험을 실시하여 맨홀 내부의 흐름특성의 변화와 에너지 손실에 대하여 분석하였다. 또한 실험조건 변화에 따른 수두 손실계수를 산정하여 직사각형 맨홀 내부의 에너지 손실을 감소시키기 위한 방안을 제시하였다.

  • PDF

A study on the power conversion losses analysis for the ZVS full bridge converter (영전압 스위칭 풀브릿지 컨버터의 전력변환 손실특성에 관한 연구)

  • Ka, Dong-Hoon;Ahn, Tae-Young;Bong, Sang-Cheol;Kim, Don-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.58-60
    • /
    • 2008
  • 본 논문에서는 영전압 스위칭 풀브릿지 DC-DC 컨버터의 회로방식에 대한 전력변환 효율 특성을 빠르고 효과적으로 분석 할 수 있는 방법에 대해 보고한 것이다. 먼저 기존회로에서 내부손실이 없는 이상적인 등가회로를 유도하고 스위칭 동작 파형을 이용하여 주요부분에 대한 전류의 실효값을 유도하였다. 이상적인 등가회로에 내부손실 저항을 삽입하고 전류의 실효값으로부터 주요소자의 전도손실을 계산하여 컨버터의 전력변환손실과 효율을 예측할 수 있도록 하였다. 해석 방법의 타당성을 검토하기 위해서 입력전압 400V, 출력전압 12V, 최대전력 720W의 시험용 회로를 구성하여 해석 결과와 비교 하였다.

  • PDF

Reduction Characteristics of Electromagnetic Fields in Cavity by Lossy Dielectric Materials (손실 유전체를 이용한 공동 내부의 전자계 저감 특성)

  • 정광현;김기채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.950-954
    • /
    • 2003
  • This paper presents the delivered power and reflection coefficient in metallic shielding enclosure excited by the interior source, which are evaluated with the method of moments, and describes a method for reducing the radiation of electromagnetic fields in the cavity by putting lossy dielectric material in one inside wall. In this paper we introduce carbon polystyrene-foam as lossy dielectric material and observe it's effects of reduction when the thickness and permittivity of lossy dielectric material are changed. The results show that the reduction of the electromagnetic radiation can be achieved by controlling the amount of carbon in lossy dielectric material. The theoretical analysis is verified by the measured delivered power.

Sound Intensity Measurement in Near Field of Thin Plate Using Strain Gauge Bridge (스트레인 게이지 브리지를 이용한 얇은 평판의 근접장 음향 인텐시티 측정 방법론)

  • 김용조;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.71-76
    • /
    • 1996
  • 스트레인 게이지 브리지와 한개의 진동변위 탐촉자를 이용하여 평판의 근접장에서 음향 인텐시티를 측정하는 방법에 대하여 설명하였다. 또한 구조감쇠의 모델링을 통하여 음향방사파워에 대한 내부손실파워의 비를 나타내는 계수를 정의하여 내부손실파워의 정도를 평가하는 척도로 사용할 수 있음을 설명하였다. 임의의 경계조건을 가지는 평판에서 2개의 마이크로폰과 1개의 가속계를 이용하여 근사적으로 측정된 음향 인텐시티와 본고에서 제시한 방법으로 측정한 음향 인텐시티가 거의 일치함을 보이므로써 제시된 측정방법의 타당성을 검증하였다. 실험에 사용된 계(system)는 일반적인 해석에서 유체부하를 무시할 수 있는 계로 평판내부의 에너지 흐름에 비하여 외부로 방사되는 소음의 에너지 흐름이 매우 작기 때문에 평판내부의 에너지 흐름으로부터 방사되는 소음의 에너지 흐름을 알아내는 것이 매우 어려울 것으로 예상되었으나 본고에 제시된 방법으로 좋은 결과를 얻을 수 있었다. 앞으로 본 방법의 측정 오차에 대한 면밀한 고찰이 있어야 할 것이다. 그리고 평판의 내부손실이 비교적 큰 경우에 본 방법의 실험적으로 검증이 필요할 것이다. 또한 실질적인 문제에 응용되어 얼마만큼 유용한 정보를 제공할 것인가를 살펴보아야 할 것이다.

  • PDF

Measurement of Gain Coefficient and Saturation Power of CW Waveguide CO_2$$ Laser (연속발진 도파형 이산화탄소 레이저의 이득계수 및 포화출력 측정)

  • 이승걸;김현태;박대윤
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.162-168
    • /
    • 1990
  • Two ZnSe loss plates were installed in the resonator of waveguide CO2 laser which consisted of Pyrex capillary tube in order to change the internal loss. By rotating the loss plates, the output variations with the internalloss was measured on various discharge conditions. The variations could be explained by the Rigrod theory. and the saturation power and the unsaturated gain coefficient were determined by fitting of the experimental results. It was found that the saturation power increased while the unsaturated gain coefficient reduced as the discharge current or the gas flow rate increased.reased.

  • PDF

Optimization of an Annular Fin with a Pipe of Variable Inner Radius for Fixed Fin Volume (고정된 휜 체적에 기준한 원관 내부반경이 변하는 환형 휜의 최적화)

  • Kang, Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.229-235
    • /
    • 2010
  • Optimum values of fin performance and dimensions for an annular fin with a rectangular profile and a pipe with variable inner radius are determined by using a variable separation method. The range of ambient convection characteristic number that results in optimum heat loss is listed. The optimum heat loss, corresponding optimum fin effectiveness, fin length, and fin height are presented as a function of the inner radius of the pipe, inner fluid convection characteristic number, fin volume, and ambient convection characteristic number. One of the results shows that the optimum heat loss, fin effectiveness and fin length increase linearly with the inner radius of the pipe when both the fin volume and fin-base radius are fixed.

An Estimation of Head Loss Coefficients at Surcharged Manhole with 90 Degree Bend Using Numerical Model (수치모형을 이용한 과부하 $90^{\circ}$ 접합맨홀에서의 손실계수 산정)

  • Kim, Jung-Soo;Lim, Ga-Hui;Han, Chyung-Suck;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.165-165
    • /
    • 2011
  • 현재 계획 또는 설계 단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 에너지 손실은 고려되지 않는 실정이다. 그러나 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 에너지 손실이 발생하게 된다(최원석과 송호면, 2002). 더욱이 직선으로 연결된 중간맨홀보다 유입관과 유출관이 $90^{\circ}$의 각도로 접합된 합류맨홀은 연결 구조상 유수교란에 의한 에너지 손실이 커질 것으로 예상됨에도 불구하고 현재 실무에서 우수 배수시설의 설계 시 직선 연결맨홀과 $90^{\circ}$ 접합맨홀의 손실을 구별하지 않고 사용하고 있는 실정이다. 그러므로 $90^{\circ}$ 접합맨홀에서 우수관거 시스템의 우수 배제 능력을 증가시켜 도심지의 침수를 방지하기 위한 관거시설의 적정 설계 기준이 필요하며, 합리적인 설계 기준을 제시하기 위하여 $90^{\circ}$ 접합맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 수리모형 실험의 물질적 및 시간적 한계를 극복하기 위하여 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 6.3 모형을 이용하여 과부하 $90^{\circ}$ 접합맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 맨홀 및 접합 관거의 기하 모형의 격자망은 수치해석의 안정성 확보를 위하여 그림 1과 같이 6면체 격자로 구성하였다. 또한 $90^{\circ}$ 접합맨홀에서 급격한 와류에 의해 발생하는 에너지 손실을 저감하기 위하여 $90^{\circ}$ 접합맨홀의 내부 형상 및 접합 조건을 변화시켜 손실계수를 산정하였다. 수치모형의 적용 결과 맨홀 내에서의 유속변화, 수심변화 및 압력변화에 대해서는 수리모형 실험 결과와 유사한 경향을 나타내고 있으며, 수치모형에 의하여 산정된 $90^{\circ}$ 접합맨홀에서 에서의 손실계수 값과 수리모형에 의하여 산정된 손실계수 값이 거의 유사하게 나타났다.

  • PDF