The Development and Performance Evaluation of a Cyclone to Remove Hot Particulate from a Contaminated Hot Cell (Hot Cell 내에 오염된 고방사능분진 제거를 위한 사이클론 개발 및 성능평가)

  • Kim Gye-Nam;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.217-226
    • /
    • 2006
  • The structural and contamination characteristics of hot cells at KAERI were investigated. The SEM results showed that the size of the hot particulate on the inner surface of the hot cell ranged from 0.2 to $10{\mu}m$. It was found that an inlet flow rate of 15 m/sec was suitable for this developed cyclone with a 49 mm optimum vortex finder length. The results showed that the collection efficiency was about 85% for $3{\mu}m$ particles. The collection efficiency didn't show a sharp increase when the inlet flow rate was faster than 15m/sec. When the temperature of the inlet flow gas was increased, the collection efficiency of the cyclone was slightly decreased. The larger the vortex finder length was, the higher the pressure drop in the cyclone was. The cut size diameter decreased with an increment of the Reynolds number. It was established that the flow in the cyclone was a turbulent flow on the basis of the Reynolds number and this turbulent flow caused a pressure drop in the cyclone. $Stk^{1/2}_{50}$ decreased with increasing values of the Reynolds number and it gradually approached a constant value at a higher value of the Reynolds number Namely, $Stk^{1/2}_{50}$ approached approximately 0.045 between 6000 and 8000 of the Reynolds number.

  • PDF

Recycling of Safety Check Valves Contaminated with Radioactivity by Chemical Decontamination (化學除染에 의한 逆止밸브의 再使用)

  • 정종헌;최왕규;원휘준;심준보;오원진
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2001
  • Chemical decontamination techniques have been employed to reuse the high cost check valves contaminated with radioactivity and to reduce the radiation exposure during the inspection and maintenance work of safety injection system containing check valves. After chemical decontamination, an ultrasonic treatment was conducted to remove the fine solid particles retained in the crevices of check valves. The decontamination process conditions and the amount of chemical reagents were determined from the results of a pre-test, using the (list arm holder. The decontamination factors (DF), estimated from the activity in the solution, ranged from 14.5 to 18.5 corresponding to the activity removal of 93-95ft. The corrosion test data indicated that the general corrosion rate during a chemical decontamination-ultrasonic treatment process are low for type 304 S tainless steel, Inconel -600 and Stellite-6 materials $ (2.1\times10^{-2}$ $6.0\times10^{-2}$ and$ 1.7\times10^{-2}$ mil, respectively).

  • PDF

Vapor Exposure Effect of a Casting Solution on the Embedding and Radioactive Detection of CAYS in Double-layered Polysulffne Film (방사능탐지용 CAYS 함침 이중구조 폴리설폰막의 형상 및 특성에 제막공정의 습도가 미치는 영향)

  • Han Myeong-Jin;Nam Suk-Tae;Lee Kune-Woo;Seo Bum-Kyoung
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.198-205
    • /
    • 2005
  • Double-layered polymer films to assay the radioactive contamination were formulated using polysulfone (PSF) and cerium activated yttrium silicate (CAYS), consisting of a dense support layer and a CAYS-holding top layer prepared via the diffusion-induced phase inversion. As the vapor exposure process was omitted, the CAYS-holding layer showed a typical asymmetric structure, with CAYS being transfixed into the polymer network spread with large macropores. With the increase in vapor exposure time before immersion, morphology of the films transformed from asymmetric to sponge-like structures, with CAYS being localized in cellular structure. The border structure between the two layers reflects the phase inversion behavior of a cast solution during the coagulation. In the radioactive detection, the polymer phase in a film holding a sponge-like structure is so dense that the radionuclides, deposited on the film, could not filter through the phase, consequently resulting in the loss in the detection efficiency of the film.

[ 137Cs] and 40K Activities of Foodstuffs Consumed in Jeju (제주지역에서 소비되는 식품 중 137Cs과 40K 방사능 농도)

  • Kang, Tae-Woo;Hong, Kyung-Ae;Park, Won-Pyo;U., Zang-Kual
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • This work was conducted to provide the reference data of radioactivity in the foodstuffs at a radiological emergency situation in Jeju Island The sampled foodstuffs were agricultural (31), livestock (6), marine (12) and forest products (4), and processed foods (3) consumed by Jeju Islanders. $^{137}Cs$ and $^{40}K$ activities were determined by HPGe r-ray spectromety. The activity ranges of $^{137}Cs$ was ${\sim}650\;mBq/kg$ fresh in the agricultural products, ${\sim}131\;mBq/kg$. fresh in the livestock, ${\sim}834\;mBq/kg$ fresh in the forest, ${\sim}253\;mBq/kg$ fresh in the marine and $32.0{\sim}483\;mBq/kg$. fresh in the processed foods (tea). In case of $^{40}K$ the activity was $16.6{\sim}542\;Bq/kg$. fresh in the agricultural products, $39.1{\sim}294\;Bq/kg$ fresh in the livestock, $85.5{\sim}116\;Bq/kg$ fresh in the forest, $50.1{\sim}657\;Bq/kg$ fresh in the marine, and $33.6{\sim}1,065\;Bq/kg$ fresh in the processed foods (tea). The highest activity of $^{137}Cs$, 834mBq/kg fresh was observed in oak mushroom and $^{40}K$ 1,065 Bq/kg fresh in coffee. Annual effective doses of $^{137}Cs$ and $^{40}K$ by intake of foodstuffs per capita were the following order; agricultural products (66,543 nSv) > livestock products (19,311 nSv) > processed foods (6,648 nSv) > marine products (6,579 nSv) > forest products (860 nSv). Therefore, total annual effective dose was summed 99,941 nSv which is quite low level comparing to the annual effective dose by external exposure, 2,400,000 nSv. The data obtained in this study can be useful for monitoring whether the foodstuffs are contaminated or not at an emergency radiation accident, and showed that the foodstuffs consumed in Jeju are safe in terms of annual effective dose of $^{137}Cs$ and $^{40}K$

Structural Analysis for the Container-Shaped Type A Package of Radioactive Materials (컨테이너형태의 방사성물질 A형 운반용기에 대한 구조해석)

  • 이영신;이호철;정성환;이흥영;김용재
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.2
    • /
    • pp.143-150
    • /
    • 2001
  • 원자력발전소의 1차 계통에서 오염된 장비들을 취급이 용이하고 안전하게 운반하기 위한 운반용기는 내부의 방사성 물질에 대한 방사능 평가에 의하여 방사성물질 A형 운반용기로 분류된다. 방사성물질 A형 운반용기는 IAEA Safety Standard Series No. ST-1 및 국내 원자력법 등 관련규정의 기술기준을 만족하여야 하는데, 운반용기는 중량에 따라 0.3∼1.2m의 높이에서 소성이 일어나지 않는 단단한 바닥면으로 가장 심각한 손상을 주는 방향으로 낙하시키는 정상운반조건(normal transport conditions)에 대하여 구조적 건전성을 유지하여야 한다. 여기서는 ABAQUS/Explicit 코드를 이용하여 컨테이너형태의 A형 운반용기에 대하여 최대손상이 야기되는 0.9m 경사낙하조건에 대한 3차원 충격해석을 수행하고 구조적 건전성을 평가하였는데, 운반용기는 경사낙하시 코너피팅(corner fitting)의 분쇄(crush)에 의하여 대부분의 충격을 흡수하였으며 운반용기의 격납경계는 구조적 건전성을 유지하였다.

  • PDF

A Study on the Natural Uranium Contamination Measuring Technology (천연우라늄 오염에 관한 방사선/능 측정기술 연구)

  • 정운수;홍상범;서범경;박진호;조용우;조성원;이정민
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.407-417
    • /
    • 2004
  • This study is to verify radiation detection method by using $\alpha$-spectroscopy and ${\gamma}$-spectroscopy for concretes and components which will be generated during the decommissioning of the uranium conversion plant. Components and inside walls of the building were contaminated with natural uranium materials. Some parts of the stainless steel pipes and concretes of the walls were sampled and analyzed their alpha and gamma activities respectively. Alpha and gamma activities are well matched each other in the range of high activity region to 0.01 Bq/g and gamma activities are over estimated comparing alpha activities corresponded in below 0.005 Bq/g region for the natural uranium of AUC sample. The $^{238}U$ originated from natural products of conversion process could be distinguished by measuring $^{214}Pb$ or $^{214}Bi$ and $^{234}Th$ or $^{234m}Pa$. Uranium contaminations mainly are in the wall surface of the plant. Decontamination process of generating wastes which can be reached tp background level gamma activities measured by gamma spectroscopy can also be used to conservative assessment data.

  • PDF

Effect of experiment process on corrosion damage of metallic material for nuclear energy instrument with chemical decontamination process (화학제염 시 시험공정이 원전기기용 금속 재료의 부식손상에 미치는 영향)

  • Jeong, Gwang-Hu;Yang, Ye-Jin;Park, Il-Cho;Lee, Jeong-Hyeong;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.136-136
    • /
    • 2017
  • 화학제염 기술은 산화제, 환원제, 금속이온, 무기산등이 혼합되어 있는 화학용액을 사용하여 원전기기 계통 내부에 생성된 고방사능 준위의 산화막과 오염물질을 제거하는 기술이다. 원전의 해체 및 유지보수에 있어 방사능 피복저감을 위한 필수적인 기술이다. 현재 원전 해체 산업은 잠재성이 높은 고부가가치 창출 산업으로 주목을 받고 있다. 원전 보유국의 경우, 기존 상용 제염기술과는 차별성 있는 제염기술을 확보하고자 노력하고 있다. 기존의 공정과 비교하여 공정비용 및 시간을 감소시킬 수 있어야 할 뿐만 아니라, 화학용액에 의한 원전 계통 금속 부품의 부식 및 손상을 최소화해야 한다. 금속 부품이 화학약품에 의한 부식손상을 받는다면 금속 부품의 수명 및 재활용 가치가 감소하기 때문에, 화학제염 기술 적용에 있어 용액에 대한 재료의 건전성 평가가 사전에 필히 이루어져야 한다. 본 연구에서는 원전 냉각재 펌프용 재료로 주로 사용되는 Stainless 304강을 시험편으로 선정하여, 화학제염 시험공정 3가지에 대한 부식손상 특성을 규명하였다. 산화공정은 과망간산($HMnO_4$) 용액을 공통으로 사용하였으며, 산화공정 종료 후 환원공정은 각 시험공정에 따라 시험공정 1은 옥살산($H_2C_2O_4$) 2000ppm, 시험공정 2는 옥살산($H_2C_2O_4$)1500ppm + 시트르산($H_8C_6O_7$)500ppm, 그리고 시험공정 3은 옥살산($H_2C_2O_4$) 3000ppm 용액을 각각 투입하여 수행하였다. 산화, 환원공정을 1Cycle로 하여, 각 시험공정 별로 총 5Cycle을 실시하였다. 각 시험공정 Cycle종료 후 시험편을 취외하여 무게감량측정, SEM(Scanning electron microscope) 분석, 3D현미경분석 그리고 타펠분극 실험을 실시하였다. 각 분석결과를 토대로 하여, Stainless 304강에 대한 화학제염 시 모델별 시험공정에 따른 부식특성을 규명하였다.

  • PDF

Cesium Removal of the Rhizofiltration Using Sunflowers (Helianthus annuss L.) and Beans (Phaseolos vulgaris var.) (해바라기(Helianthus annuss L.)와 강낭콩(Phaseolos vulgaris var.)을 이용한 뿌리여과법(rhizofiltration)의 세슘 (cesiun) 제거)

  • Yang, Min-June;Lee, Min-Hee
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.709-717
    • /
    • 2008
  • Rhizofiltration for cesium uptake by sunflowers (Helianthus annuus L.) and beans (Phaseolus vulgaris var.) was investigated for groundwater contamination. The cesium removal by sunflowers was greater than 98% of the total cesium in solution, and the uptake by beans was also greater than 99% within 24 hours of the rhizofiltration, showing that the rhizofiltration has a great capability to remove cesium from the contaminated water system. Experiments at various pH of solution indicated that a solution of pH $5{\sim}9$ yielded very high cesium accumulation in two plants. From the results of the analysis for cesium accumulation in plant parts, about 80% of cesium transferred into the plant from solution was accumulated in the root part and less than 20% of cesium existed in the shoot part (including leaves). Results suggest that only the roots of the fully grown plant used for rhizofiltration should be disposed or post-treated and thus the cost and time to treat massive amounts of grown plants could be dramatically reduced when sunflower and bean are used in the real field. The results of SEM and EDS analyses indicated that the most of cesium were accumulated in the root surface as a ionic phase rather than a soil precipitation phase.

Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients (갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Hong, Sang-Woon;Kim, Jang-Hee;Kim, Ki-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

  • PDF

Development and Performance Evaluation of a Filtration Equipment to Reuse PFC Waste Solution Generated on PFC Decontamination (PFC 제염 시 발생된 PFC 폐액의 재사용을 위한 여과장치 개발 및 성능평가)

  • Kim Gye-Nam;Jeong Cheol-Jin;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.161-170
    • /
    • 2006
  • PFC(Perfluorocarbon) decontamination process is one of best methods to remove hot particulate adhered on the inner surface of hot cell and surface of equipment in hot cell. It was necessary to develop a filtration equipment to reuse the PFC waste solution generated on PFC decontamination due to the high cost of PFC solution and for minimization of the volume of second waste solution. The filtration equipment was developed to remove hot particulate in PFC waste solution. It was made suitable size and weight in consideration of hot cell gate and crane. And it has wheels for easy movement. Flux of the filtration equipment decreased with particulate concentration increase. It consists of pre-filter($1.4{\mu}m$) and final-filter($0.2{\mu}m$) for protection of the flux decrease along filtration time. It treatment capacity of waste solution is 0.2 L/min.