• Title/Summary/Keyword: 내벽

Search Result 298, Processing Time 0.028 seconds

A Study on the Development of the System for Inspecting Cracks in the Inner Wall for Structures (구조물 내벽의 균열 검사를 위한 시스템 개발에 관한 연구)

  • 이상호;신동익;손영갑;이강문;마상준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.480-483
    • /
    • 1997
  • In this paper, we have proposed an automatic inspection system for cracks on the surface of a structure. The proposed system consists of the imaging system and the veh~cle system. The imaging system. a set of optical sensor, lens, illuminator, storage and their configuration, images the scene and store it on the hard disk. We adopted a linescan camera of 5000 pixel density to achieve high resolution without loss of simplicity. The vehicle system that moves the optical system IS ~mplemented by an AGV. The AGV moves forward at constant velocity and avoid obstacles to acquire a stable image. We have cmplemented an experimental system and have acquired images of the wall of hallway. The image is of 0.1-mmipixel resolution and the scanning time IS about 1 mlsec. The allow able scan.

  • PDF

Fullly Developed Turbulent Flow and Heat Transfer in Concentric Annuli with Square - Ribbed Roughness (사각형 거칠기가 있는 동심이중관 내의 완전히 발달된 난류유동과 열전달)

  • 안수환;오세경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.41-50
    • /
    • 1994
  • 동심 이중관내에서 외관내벽의 사각돌출형 조도요소에 의한 비대칭 난류유동과 열전달 특성을, 열전달과 마찰계수에 미치는 조도의 합성효과를 조사하기 위해, 연구하였다. 이론해석에서는 수정 플란틀 혼합길이(mixing length)이론의 난류모델을 속도분포와 마찰계수를 구하는데 사용하였다. 최대 속도지점에서 안쪽과 바깥쪽의 두 속도 형상들은 힘의 평형에 의해 일치시켰다. 그리고나서, 온도분포와 열전달 계수를 계산하였다. 속도형상과 마찰계수들의 해석결과는 반경비 (${\alpha}$)= 0.13, 0.26, 0.4, 그리고 0.56 경우의 실험과 매우 잘 일치하였다. 마찰계수와 Nusselt number에 미치는 반경비, 조도비, 그리고 조도에 대한 피치비 등과 같은 여러 변수들의 효과들을 조사하였다. 본 연구는 일정 조도 요소들이 전체적 효율 측면에서 볼 때 열전달을 우리하게 향상시킨다는 것을 증명하였다.

  • PDF

Performance Analysis of Wireless Sensor Nodes over Indoor and Outdoor Environments (실내외 환경에서 센서노드의 성능 평가)

  • Di, Xuechao;Moon, Byung-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.2
    • /
    • pp.1-9
    • /
    • 2012
  • Wireless sensor nodes are widely used for various applications such as environmental monitoring. In this paper, the RSSI and PER are measured for the indoor environment with the various interferences such as obstacles(concrete walls, steel doors) and the 2.4GHz wireless LAN interference. Also, the RSSI and PER are measured for the outdoor environments. From the measured values of the RSSI and PER, the guideline for the stable operation of the wireless sensor network is suggested.

The Use of Urokinase in Ischemic Free Tissue Transplantations - An Experiment Using the Ischemic Replanted Rabbit Ear Model - (허혈성 유리조직 접합술에서 Urokinase의 효용성 - 토끼 이개를 이용한 실험 -)

  • Lee, Jun-Mo
    • Archives of Reconstructive Microsurgery
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • 장시간 허혈상태의 토끼 이개를 실험대상으로 하여 유로키나제와 헤파린을 병용 또는 단독으로 사용시와 또한 약물을 사용하지 않았을 때, 이들이 모세혈관의 개존성과 아울러 미세수술후의 조직 생존율에 미칠 수 있는 효과를 보기 위하여 허혈상태의 토끼 이개를 미세수술로 접합한 후 모세혈관으로의 혈류를 측정하기 위하여 레이저 초음파 혈류측정기(Laser doppler flowmetry)를 이용하였으며 방사선 구슬들(Cobalt-57 with plastic material with average diameter 15 micron)을 주입한 결과 유로키나제 조합에서 통계적으로 유효한 성적을 얻었다. 광학현미경 소견은 유로키나제와 헤파린을 병용한 조합에서 모세혈관내 내피세포의 배열이 유지되어 있었으며 헤파린을 사용한 조합에서도 유사한 소견을 보였으나 약물을 사용하지 않은 조합에서는 국소적인 내피세포의 배열이 결핍되어 있었다. 전자현미경 소견에서 유로키나제와 헤파린을 병용한 조합에서 내피세포가 혈관내벽에 배열되어 있었고 또 불규칙한 세포질이 돌출되어 있었다.

  • PDF

The Effect on Cabinet Deformation by Bead of Inner Case (가정용 냉장고의 냉동실 내벽의 비드가 케비넷 변형에 미치는 영향)

  • Cho, J.R.;Zhai, J.G.;Shin, M.G.;Kim, J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.427-428
    • /
    • 2009
  • In the manufacture process of refrigerator cabinet, polyurethane(PU) liquid firstly is injected between outer plate and inner case in high temperature about $40^{\circ}C$, and PU foam is generated and solidified to the room temperature. There will be great residual stress in the PU foam, especially at the corners after the whole refrigerator is completely assembled. The stress condition will become more complicated under operating condition because of the large temperature difference between the freezing room and outer plate. And also, there are great differences of properties for plastic and steel which would cause different deformation under temperature gradient. The steel outer plate would expand compared to the PU foam or ABS material under operation condition, which induces a thermally bowing deformation in the refrigerator cabinet. The objective of this paper is to design an optimum bead structure or to use reinforcement in the refrigerator except for improving material properties in order to decrease the deformation.

  • PDF

Effect of Inner Tube on Flow Field and Particle Behavior inside Bag Filtration System with Tangential Inlet (접선유입방식의 여과집진장치 내에서의 내통이 유동장 및 입자거동에 미치는 영향)

  • 박석주;김상도;최호경;박영옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.263-264
    • /
    • 2000
  • 여과포 표면상에 도달하는 입자의 농토를 낮추거나 균일하게 유지시킬 경우, 부착된 입자층 두께의 성장으로 인한 압력손실의 증가율을 줄일 수 있고 이로 인하여 탈진 주기 또한 감소시킬 수 있다. 탈진조작의 저감으로 인하여 여과포의 수명 증대로 여과포의 교체 시기를 연장시킬 수 있으므로 여과포 집진장치의 운전 및 유지 보수비의 저감을 이룰 수 있다. 본 연구에서는 집진용기의 중간부분에 위치한 접선 유입관을 통하여 오염입자를 함유한 기체유동을 유입시킨 후, 원심력과 난류확산에 의하여 집진용기 내벽과 내통(inner tube) 벽면에 부착된 입자는 중력에 의하여 용기 바닥으로 모인 후 바닥면에 설치된 스크래퍼(scraper)를 통하여 분리 처리될 수 있는 새로운 형상의 집진장치를 개발하고자 하였다. (중략)

  • PDF

배관 세척장치의 성능평가

  • 조정식
    • 월간 기계설비
    • /
    • s.119
    • /
    • pp.71-83
    • /
    • 2000
  • 점차 복잡해지고 있는 사회적 욕구를 만족시키기 위한 건물에서는 반드시 복잡한 설비가 요구되고 있고, 이러한 설비시스템 중에는 급수, 급탕 및 배수설비라고 하는 배관시스템이 없다면 기능유지에 막대한 지장을 초래할 것은 자명하다고 하겠다. 이러한 배관시스템에서는 항시 또는 일부 사용되어질 물이나 사용된 물이 흐르기 때문에 배관내부에 발생하는 스케일(scale)이나 슬라임(slime) 등은 피할 수 없는 사실인 것이다. 건축물 내에 설치된 각종 배관은 건물의 기능을 유지하고 보건위생과 직결되는 중요한 기능을 담당하고 있어 세척의 필요성이 매우 높음에도 불구하고 배관의 수명이 다할 때까지 거의 세척이 이루어지지 않고 사용되어 왔다. 이들 배관에 대한 세척은 배관의 수명연장과 관마찰 계수를 낮추어 급수의 수송동력을 절감할 수 있고, 난방관의 열전달 효과를 높여 에너지 절약 효과를 거두어 건물의 유지관리 비용 절감에 기여할 수 있음에도 적절한 세척공법이 개발되지 않고 있다. 이러한 관점에 맞추어 건물배관의 특성에 맞도록 고압 세척장치를 개발하고 이를 이용한 세척공법을 적용하고자 하였다. 즉, 배관 내에 압축공기를 주기적으로 분사하여 맥동현상이 일어나도록 하면서 기포를 발생시켜 기포가 관의 내벽에서 성장하여 파괴될 때 관내에 부착된 이물질을 제거할 수 있고, 또한 세척효과를 높이기 위하여 관의 벽면에 접촉하면서 배출되는 과정에서 이물질을 제거할 수 있도록 구조와 아울러 이들 장치를 이용한 세척방법의 적용성에 대해서 고찰하고자 한다.

  • PDF

내벽에 게터를 장착한 진공용기의 도달진공도 측정

  • Yang, So-Hui;Park, Seok-Jun;Park, Jong-Do;Ha, Tae-Gyun;Kim, Se-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.139.2-139.2
    • /
    • 2014
  • 방사광 가속기의 저장링 진공용기처럼 콘덕턴스가 배기성능을 좌우하는 진공용기에서는 Strip NEG를 사용하여 분산 배기를 함으로서 원하는 평균진공도를 확보할 수가 있다. 일부 연구소에서는 진공용기 자체를 게터로 코팅하여 사용하고 있으나 그 제작비용이 만만치가 않다. 이 연구에서는 쉽게 구할 수 있는 동전모양의 작은 게터를 진공용기 내부에 길이 방향으로 일렬로 배치하여 분산배기가 실제 가능한 지 평가하였다. 게터는 진공용기 자체를 $180^{\circ}C$ 이상 베이크아웃할 때 활성화되도록 하였다. 실험은 단면적 $13cm^2$, 3 m 길이의 압출형 알루미늄 진공용기로 베이크아웃 온도에 따른 진공도 변화를 측정하여 그 성능을 평가하여 보고하고자 한다.

  • PDF

Benedenia derzhavini (Trematoda : Monogenea) from Cultured Korean Rockfish, Sebastes schlegeli, in Korea (양식 조피볼락에서의 Benededia derzhavini 기생에 관한 국내 보고)

  • Kim, Ki-Hong;Kwon, Se-Ryun
    • Journal of fish pathology
    • /
    • v.11 no.1
    • /
    • pp.83-86
    • /
    • 1998
  • The benedeniine monogenean Benedenia derzhabini (Layman, 1930) Meserve, 1938 from cultured Korean rockfish, Sebastes schlegeli, is described and reported for the first time in Korea. The parasite was recovered from the gills and inner wall of operculum. B. derzhavini is distinguished from B. seriolae and B. sebastodis by the relative shape and length between the accessory sclerites and the hamuli.

  • PDF

Study on Liquid Walls for Fusion Device (핵융합 장치를 위한 액체 벽 연구)

  • Choe, Yong-Seop;Park, Hyeon-Jae;No, Tae-Hyeop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.34-34
    • /
    • 2012
  • 핵융합 장치의 액체 벽 연구에 관해 정리 하였다. 액체 벽은 1970년 Field Reversed Configuration 장치의 first wall로써 Christofilos에 의해 처음으로 제안되었다. 액체 벽은 순환을 통해 벽 손상을 막을 수 있는 장점이 있으나, 플라즈마와의 반응 시 증발로 인한 중심 플라즈마 불순물 증가 문제와, 진공 용기 내벽에 유동을 만들어야 하는 어려움이 있다. 본 논문에서는 그 동안 제안된 액체 벽 개념에 관한 검토와 국가핵융합 연구소 플라즈마 기술연구센터에서 수행하고 있는 액체 벽 관련 연구에 대해서 발표하고자 한다. 국가핵융합 연구소 플라즈마 기술연구센터에서는 용융염(FliNaK, LiF+NaF+KF)을 이용하여 수소 플라즈마와 용융염과의 반응에 관한 기초 연구를 수행하여 왔다. 기초 연구로써 수소 플라즈마 반응 유무에 따른 용융염 증발특성 변화, 용융염 내 수소 함유량 변화 측정, 수소 플라즈마 반응 시 광 진단을 통한 용융염 증발 성분 확인 등의 연구를 수행하였다. 또 진공 챔버 내부에 용융염 순환 시스템을 제작하여, 흐르는 용융염과 플라즈마와의 반응을 연구할 수 있는 실험 장치를 최근 제작 설치하였다. 본 논문에서는 중요한 기초 실험 결과와 용융염 순환 시스템 설계 인자에 대해서 논의하고자 한다.

  • PDF