• Title/Summary/Keyword: 내경(內徑)

Search Result 862, Processing Time 0.034 seconds

A Study on the Acoustic Analysis Method of the External Ear Canal Using DICOM Images (DICOM 영상을 이용한 외이도 음향해석 방법에 관한 연구)

  • Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.3
    • /
    • pp.73-79
    • /
    • 2019
  • This study simulated external ear canal modeling with different external ear canal lengths, vertical flexion angles, and inner/outer diameter ratios using digital imaging and communications in medicine(DICOM) of the head temporal region and measured the acoustic sensitivity. The experiment was performed by increasing the audible frequency for humans by 200 Hz and expressing the frequency constantly transmitted at 1 Pa as the eardrum acoustic volume and presented the measurements by linear and quadratic curve regression analysis. The results showed that the longer the external ear canal length and the higher the ratio of the outer/inner diameter, the faster the acoustic response at lower frequencies. The acoustic sensitivity correlation of the meta-model using regression analysis showed a 77% influence by the external ear canal length and 5% by the external/internal diameter ratio, while the vertical flexion angle did not show a significant relationship. This showed that auditory acoustic sensitivity of humans is a factor that reacts faster at a low frequency when the external ear canal length is longer and when the difference between the outer and inner diameter is higher.

Persistent Trigeminal Artery Variant Terminating in the Ipsilateral Superior Cerebellar Artery (상소뇌동맥영역을 공급하는 지속성 원시 삼차신경동맥 변이)

  • Tae Young Park;Byung Hoon Lee;Yoon Joon Hwang;Ji Young Lee;Suk Hyun Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.184-188
    • /
    • 2022
  • Persistent trigeminal artery (PTA) represent an unusual remnant of the fetal carotid-basilar anastomosis. Persistent trigeminal artery variant (PTAV) is a rare anastomosis between the internal carotid artery and cerebellar artery, without an interposing basilar artery segment. We report the case of 49-year-old female with an incidentally discovered, rare variation of PTA that directly terminated in the ipsilateral superior cerebellar artery. The variation was observed on CT angiography, digital subtraction angiography, and MR angiography. Additionally, we reviewed the embryogenesis of PTA and PTAV and discussed the clinical implications of this variation.

Measurement of the Common Carotid Artery by Ultrasound as a Predictor of Atherosclerosis in Obese Adolescents (비만 청소년에서 동맥경화증을 조기에 예측하기 위한 경부 초음파를 이용한 경동맥 측정)

  • Kim, Ye Jin;Shim, Yoon Hee;Yoo, Joung Hyun;Lee, Keun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.745-752
    • /
    • 2005
  • Purpose : Adolescent obesity is known to be associated with complications such as hypertension, coronary artery disease and insulin resistance. We measured the common carotid artery by ultrasound as a predictor of atherosclerosis, and investigated the relationship between carotid artery parameters and serum cytokines in obese adolescents. Methods : Twenty-nine obese adolescents(16-17 years old, obesity index>130 percent) and twentyseven normal controls were included. Obesity index and body mass index were calculated from their height and weight. Skin fold thickness was measured at the triceps, and fat mass and fat distribution by bioelectrical impedence analysis. Blood pressure was measured at resting state and serum lipid, insulin, and homocysteine levels after a 12-hour fasting period. Intimal wall thickness, systolic and diastolic diameters of the common carotid artery were measured by ultrasound, and compliance and distensibility calculated by equation. Results : Systolic and diastolic diameters of the carotid artery significantly correlated with arm circumference, body mass index, fat distribution and fat mass. The higher systolic blood pressure was, the larger systolic and diastolic diameter. The higher diastolic blood pressure was, the larger carotid intimal thickness. Insulin levels had positive correlations with systolic, diastolic diameters and serum homocysteine level with intimal thickness. Conclusion : The carotid artery diameter significantly increased with the degree of obesity and blood pressure. The carotid intimal wall thickness significantly correlated with diastolic blood pressure. Measurement of carotid artery thickness, insulin and homocysteine levels might be useful to predict the development of coronary artery disease.

Follow-Up Method in Patients with Kawasaki Disease who had No Coronary Artery Abnormalities in the Convalescent Period (회복기 심초음파 검사상 관상동맥 내경 크기가 정상 범위인 가와사끼병 환자에서 추적관찰 방법에 대한 고찰)

  • Joo, Hee Jung;Song, Min Seob;Kim, Chul Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.165-173
    • /
    • 2005
  • Purpose : We performed the study to evaluate the value of the follow-up echocardiogram performed 6 months to 1 year after the onset of Kawasaki disease(KD), as recommended by American Heart Association(AHA) guidelines, when echocardiograms in the convalescent period were normal. Methods : Patients were selected from 147 cases diagnosed with KD at Pusan Paik hospital from January 2000 to October 2003. A total of 45 KD patients belonged to AHA risk level I and II were performed follow-up echocardiography. The patient's medical records and echocardiogram were reviewed. Additionally, we sought the opinion of pediatric cardiologists on the subject by means of a multiple-choice survey. Results : 37 children were belonged to AHA risk level I and the remaining 8 patients were belonged to risk level II. Of these 45 children, none were noted to have abnormalities on later follow-up echocardiogram. In the results of questionnaire, 37 percent of the participants advocate no follow-up after convalescent period for risk level I, and 33.3 percent favor periodic follow-up with echocardiography for risk level II up to one year. But there were no consensus about the diagnostic criteria of coronary abnormalities and how to follow-up these patients. Conclusion : All children with KD should have an echocardiogram at present and a follow-up study 6 to 8 weeks after the onset of fever. However, additional echocardiographies are not justified if the 6- to 8-week follow-up echocardiogram is normal. We would recommend that the more reasonable diagnostic criteria for coronary abnormalities and the Korean guidelines for long-term cardiovascular management and follow-up of KD need to be established.

Intraoperative Measurement and Analysis of Coronary Artery Bypass Graft Flow (수술중 측정한 관상동맥 우회도관 혈류량의 분석)

  • Park, Kye-Hyun;Chae, Hurn;Yun, Yang-Ku;Lee, Jae-Woong;Kim, Kwhan-Mien;Jun, Tae-Gook;Kim, Jhin-Gook;Shim, Young-Mog;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.760-769
    • /
    • 1997
  • This study aimed to determine factors that influence blood flow through coronary bypass grafts and to analyze relationship between the graft flow and postoperative outcome. Blood flow through 146 bypass grafts(GBF) was measured with transit-time ultrasound flowmeter during coronary artery bypass grafting operations in 50 patients. Single and multiple regression analyses were done for relationships between the GBF and four variables: internal diameter of recipient coronary artery, myocardial value of bypassed branch(es), type of graft, and finding of preoperative myocardial perfusion scan. The relationship between GBF and postoperative scan finding was also analyzed. 1. The mean GBF was significantly higher in sequential grafts than in single vein grafts or in internal thoracic artery grafts(61.5 vs. 46.9 and 42.5 ml/min). 2. Myocardial value and recipient artery diameter were found to be the factors determining GBF. There was no correlation between GHF and presence of perfusion defect in the preoperative scan. 3. Myocardial value was found to be more important than recipient artery diameter in determinintg GBF. 4. Reversible perfusion defects were more frequently found in the areas upplied by grafts with low GBP. But this fact had only mild statistical significance. These results suggest that blood flow through a bypass graft is more determined by the size of its supplyinf: myocardium than by the size of recipient artery. So, we can expect effective improvement in myocardial flow reserve after grafting of small(1~1.5mm) coronary arteries, if they supply substantial area of myocardium.

  • PDF

Venous Congestion in Cerebral Hyperperfusion Syndrome: A Case Report (뇌과관류증후군에서 보일 수 있는 정맥울혈 1례)

  • Bong, Jeong Bin;Kang, Hyun Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.84-87
    • /
    • 2017
  • Cerebral hyperperfusion syndrome (CHS) is a rare complication that can occur when conducting stent insertion or endarterectomy in patients with carotid artery stenosis and is known to be caused by various mechanisms when the blood volume abruptly increases. The main clinical symptoms are unilateral headache, hypertension, seizure, and focal neurologic deficit. Subarachnoid hemorrhage and parenchymal hemorrhage may lead to permanent impairment or death in severe cases. CHS can be predicted by using transcranial Doppler, perfusion magnetic resonance imaging, and single photon emission computed tomography. In our case report, a patient developed CHS subsequent to significant venous congestion caused by carotid artery stent insertion. The patient had preexisting, symptomatic bilateral carotid artery stenosis. Venous congestion occurs when the direction of blood flow changes because of increased blood volume in patients with well-developed collateral vessels. We believe that CHS can be predicted from this finding. This study reports the possibility that CHS could be confirmed by cerebral angiography after insertion of the internal carotid stent.

Design of An Open-Ended Coaxial Cavity Resonator (한쪽 면이 열린 동축 공동 공진기의 설계에 대한 연구)

  • Lee, Yun-Min;Kim, Jin-Kook;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.201-208
    • /
    • 2013
  • This paper is a study of an empirical design of an open-ended coaxial cavity resonator. It can be done by using the radius of the inner conductor, the inner radius and the length of the resonator. However, the basic coaxial transmission -line theory can be seen that the characteristics of the resonant frequency and the Q value are varied by the change of length, regardless of the value of radius of the inner conductor and inner radius of the resonator. We find out the impact of radius of the inner conductor, inner radius of the resonator and the length of the resonator parameter and propose the optimized empirical resonator design method by reducing the error between the theoretical value and the design value. Based on the simulation, several resonators are fabricated by the size of 14 mm for the radius of inner conductor, 2 mm, 5 mm, 10 mm respectively for the inner radius of resonator, and 8.5 mm for the length of the resonator. The resonant frequencies of the produced resonators were measured at 6.1, 5.7, 6.5 GHz respectively. According to the result of simulation and measurement, we know that we can design the relatively exact open-ended coaxial cavity resonator by applying the basic coaxial transmission-line theory directly when the length of the resonator is less than 10 mm, and adding the correction factor of 0.5 GHz to the calculated resonant frequency in case of more than 10 mm of the length of the resonator.

Effect of Heat Treatment on Properties of Tungsten Embolization Coils (텅스텐 색전코일의 특성에 미치는 열처리 효과)

  • Son, Ung-Hui;Hong, Sun-Hyeong;Sin, Gyeong-Min;Lee, Yun-Sin;Park, Jae-Hyeong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.333-339
    • /
    • 1998
  • The effect of heat treatment conditions on the properties of tungsten(W) embolization coils has been evaluated. The W embolization coils were fabricated by coiling the primary W coil with a diameter of 30.mm on a alumina rod mandrel with a diameter of 2.92mm. The secondary coils were then heat treated at 475$^{\circ}C$and 600$^{\circ}C$ for various heat treatment time ranging from 5 minutes to 36hours. The pitch distance, diameter and shape retention capability of the W embolization coils were characterized after the heat treatment. The pitch distance of the W embolization coils increased with the heat treatment time. The diameter of W emboliazation coils decreased continuously with heat treatment time. The shape retention capability of the W embolization coils increased with the heat treatment time due to an increase in elasticity by formation of tungsten oxide film on W coil surface during the heat treatment. The heat treatment condition of W embolization Col at 600$^{\circ}C$ for 20 minute was considered desirable based on the optimization of the shape retention capability, pitch distance and secondary coil diameter after heat treatment.

  • PDF

Manufacture of Low-Speed Type Inductive Coupler Using Nano-Crystalline Alloy (나노결정 합금재료를 이용한 저속형 비접촉식 커플러의 제조)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Lee, Jun-Hui;Lee, Hae-Yeon;Huh, Jung-Sub;Oh, Young-Woo;Byun, Woo-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.228-228
    • /
    • 2007
  • 전력선 통신용 비접촉식 커플러는 고속형(2~30 MHz)과 저속형(100~450KHz)으로 나누어 볼 수 있는데, 고속형은 현재 국내에서 독자적으로 개발되어 다양한 모델이 적용되고 있는 상황이지만, 저속형은 시작품수준으로 제조되어 있으나 신호전송 특성의 향상절구가 필요한 상황이다. 전력선 통신용 커플러는 전력선 또는 모뎀으로 통신신호를 전달하는 기능을 하는 것으로서, 전력선 통신을 위한 핵심부품이다. 따라서 본 연구에서는 100~450 KHz 대역에서 사용 가능한 저속형 비접촉식 커플러를 제조하기 위해, 권선조건, 대전류형 자심재료의 모의 해석, 노이즈 필터조건, 임피던스 매칭, 하우징방법 등의 각 공정 변수를 확립하고자 하였다. 자심재료의 모의해석에서 자심재료의 높이와 전력선 도체 단면적 변화는 자심재료의 전류포화특성에 영향을 미치지 않으며, 유효길이와 에어-갭 크기가 증가할수록 전류포화특성은 향상되는데, 자심재료의 내경이 64 mm일 때 자심재료의 폭((외경-내경)/2)은 15 mm 이상이어야 하고, 에어-갭은 약 $600\;{\mu}m$ 정도의 에어-갭을 형성시켜야함을 확인할 수 있었다. 또한 저속용 비접촉식 커플러 제조조건 실험에서 내경${\times}$외경${\times}$높이가 $64{\times}94{\times}140mm$인 자심재료를 이용하여 권선 수와 에어-갭을 각각 3회, $400{\sim}600\;{\mu}m$ 삽입했을 때, 가장 우수한 특성을 나타내었다. 그리고 저역 통과 필터를 출력부에 내장하여 통신신호 이외의 노이즈를 제거할 수 있었다. 본 연구에서 제조된 300 A급 지중선용 저속형 비접촉식 커플러는 내경${\times}$외경${\times}$높이가 $58{\times}1144{\times}158mm$이고, 100~450 KHz 통신대역에서 약$7{\pm}2dB$의 삽입손실을 나타내었다.

  • PDF

The Analysis of Usage of the '心' letter in 『HwangJeNaeGyeogYoungChu』 (『황제내경영추(黃帝內經靈樞)』에서 사용된 '심(心)'자(字)의 용례 분석)

  • Bak, Jae-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.10
    • /
    • pp.774-787
    • /
    • 2021
  • This thesis is a follow-up study on HwangJeNaeGyeogSoMun(SoMun). Its purpose is the usage of '心' letter used in HwangjenaegyeogYoungChu(YoungChu). The original manuscript of this study was the Hu's Gulin Sanctum of YoungChu. It was conducted by a literature review. Typically, the word '心' means a tangible heart and an intangible mind in the same form. Therefore, in order to understand the contents of the YoungChu, which provides the basis for the basic ideology related to health care, meditation, GiGong training, yoga, practice and oriental medicine, it is necessary to understand the meaning of the word '心' letter. The results of this study are as follows. First, it means human heart. Second, it means the human chest. Third, it means mind such as angry, joy sad, fear and so on. Fourth, it means the transcendent concept like spiritual enlightenment. Fifth, it means the pericardium. Sixth, it means logical thinking. Seventh, it means center or core, Eighth, it means the name of the constellation in the eastern sky of ancient Asia. Ninth, it can be classified into the inside. It can be used as a basic data to understand the contents of YoungChu related to various categories. The limitation of it is that the classification of the '心' letter may be different from the researchers' perspective.