• Title/Summary/Keyword: 낮은선량

Search Result 342, Processing Time 0.027 seconds

Robust Planning of Intensity-modulated Proton Therapy for Prostate Cancer (전립선암 치료를 위한 세기조절 양성자 로버스트 치료계획)

  • Park, Su Yeon;Kim, Jong Sik;Park, Ju Young;Park, Won;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the dosimetric properties of robust planning strategy for plain intensity-modulated proton therapy (IMPT) taking into account of the uncertainties of effective proton range and set up error as compared to photon intensity-modulated radiation therapy (photon-IMRT) in prostate cancer treatment. Materials and Methods: The photon-IMRT (7 beams, step & shoot), plain-IMPT (2, 4, and 7 portals), and robust- IMPT plans, which was recalculated the plain-IMPT based on the uncertainties of range error (${\pm}5%$) and set up error (0.5 cm), were evaluated for five prostate cancer patients prescribed by 70 Gy/35 fractions. To quantitatively evaluate the dose distributions, several parameters such as maximum dose, minimum dose, mean dose, conformity index (CI), and homogeneity index (HI) for PTV as well as dose-volume index of VxGy for OARs were calculated from dose-volume histograms. Results: Robust-IMPT showed superior dose distributios in the PTV and OARs as compared to plain-IMPT and photon-IMRT. Like plain-IMPT, robust-IMPT were resulted in dose fluctuation around OARs, while better homogeneity and conformity in PTVs and lower mean dose in OARs as compared to photon-IMRT. Conclusion: In consideration with the effective range correction and set up movement using robustness in IMPT plan, the dosimetric uncertainties from plain-IMPT could substantially reduce and suggest more effective solutions than photon-IMRT in prostate cancer treatment.

  • PDF

Measurement of the Natural Radiation Dose in the Ski Field (Focusing on the Gyeonggi Province area) (스키장의 자연방사선량 측정(경기도 지역을 중심으로))

  • Jung, Hongmoon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.117-122
    • /
    • 2017
  • With the increase in leisure life, the population of ski resorts is rapidly increasing. The activity at the ski resort is likely to receive a direct chance of natural sunlight or space ray. Because it is located in the mountains where altitude exists. As a general rule, it is widely known that the higher the elevation rate, the more increasing the natural radiation dose. However, the natural radiation dose rate for the ski slopes has not been reported yet. Various ski resorts exist in Korea, but this study had chose 4 ski resorts to measure the natural dose of natural radiation. As a result, the natural radiation dose for the ski slope was measured at a relatively high dose of ordinary living areas. However, the level of natural radiation dose was not worrisome. It is recommended to wear ski wear or goggles to minimize natural radiation exposure at the ski slopes.

The Study of Energy Compensation Filter Thickness for Each Energy Area of Low Energy X-ray Beam Optimization on Active Electronic Personal Dosimeter (능동형 전자식 개인피폭선량계의 저에너지 X선 영역별 최적화를 위한 에너지보상 필터 두께에 대한 연구)

  • Kim, Jung-Su;Park, Youn-Hyun;Chae, Hyun-Sic
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.519-526
    • /
    • 2022
  • Electronic personal dosimeter (EPD) provide real time monitoring and a direct indication of the accumulated dose or dose rate in terms of personal dose. Most EPD do not perform well in low energy photon radiation fields present in medical radiation environments. It has poor responsibility and large error rate for low energy photon radiation of medical radiation environments. This study evaluated to optimal additional filtration for EPD using silicon PIN photodiode detector form 40 to 120 kVp range in medical radiation environments. From 40 to 80 kVp energy range, Al 0.2 mm and Sn 1.0 mm overlapped filtration showed good responsibility to dose rate and from 80 kVp to 120 kVp energy range, Al 0.2 mm and Sn 1.6 mm overlapped filtration showed good responsibility to dose rate.

TLD's Glow Curve and Radiation Exposure Amount Analysis at Environment with/without Magnetic Field Exposure as Time Passing (시간 경과에 따른 자기장 노출 유·무 환경에서 열형광선량계의 글로우 곡선 및 피폭 방사선량 분석)

  • Lee, Jae-Heon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.419-426
    • /
    • 2016
  • The research is done to analyze the change of personal dosimeter according to the elapsed times(24 hours, 1 week, 2 weeks, 3 weeks, 4 weeks) and magnetic field and find out the effective exposure treatment for radiation workers. At first, research the heat treatment and radiation of grouped TLD and keep them in different environments-exposed separately to observe the consequences of glow curve and the level of radiation exposure. As a result, we could find that 24 hours passing TLD group showed the difference in glow curve and the level of radiation. This can be considered as the change caused by magnetic exposure. Also the average radiation exposure level of TLD group, unexposed to the magnetic field, was 15.41 mSv. And the average radiation exposure level of TLD group, exposed to the magnetic field, was 14.83 mSv which decreased the biggest amount(3.80%) among the other groups. If a radiation worker, who works in PET-MRI room, uses TLD as a personal dosimeter, the level of real radiation exposure caused by exposure to the magnetic field won't change significantly as recorded at a regular record cycle but with not regular record but interim record, the lower exposure dose will be appeared than the real level of radiation.

Reduced Effect of kV-CBCT Dose by Use of Shielding Materials in Radiation Therapy (방사선 치료 시 차폐물질 사용에 따른 kV-CBCT 선량감소 효과)

  • Jo, Hyeonjong;Park, Euntae;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.467-474
    • /
    • 2018
  • CBCT is useful for improving the accuracy of the treatment site, but Repeated use increases the exposure dose. In this study, we aimed to provide basic data for dose reduction in CBCT implementation by dataization the simulating and dose reduction effect using shielding substance. Material in this study, Analyzation the photon beam by simulate the CBCT Through MCNPX and then calculate the absorption dose of body organ at shooting moment of thoracic abdominal position as target UF-Revise simulated body. At this time. Dose reduction effects at this time were evaluated according to the texture of materials and presence of shielding materials( lead, antimony, barium, sulfate, tungsten, bismuth). When CBCT was taken without shielding, the dose was calculated to be high in the breast and spine, and the dose in the esophagus and lung was calculated to be low. The doses according to the shield material were calculated as barium sulfate, antimony, bismuth, lead, and tungsten. The shielding rate was the highest in the thymus (73.6%) and the breast (59.9%) compared with the dose reduction according to presence or absence of the shield. However, it showed the lowest shielding rate in lung (2.1%) and spine (12.6%).

Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis (Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량)

  • Kim, Kye-Sun;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.347-353
    • /
    • 2015
  • The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

Evaluation of Surface Dose for Field-in-Field (FIF) Technique in Breast Radiotherapy (유방암 방사선치료에서 Field-in-Field (FIF) 기법의 조사면 주변 선량 분석)

  • Il-Hoon, Cho;Daehong, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.851-856
    • /
    • 2022
  • The purpose of this study is to confirm the effect of reducing the surface dose around the radiation field in breast cancer radiotherapy using the Field-in-Field (FIF) technique. X-ray was exposed from a linear accelerator (Linac) was used for irradiation, and the surface dose was measured with a glass dosimeter. The source-to-surface distance (SSD) was 90 cm, the field size is 10 × 10 cm2, and the X-ray energy was 6 MV and 10 MV, respectively. The surface dose of the FIF was compared with the dose measured in the physical wedge (PW) and dynamic wedge (DW). Wedge angles of 15° and 30° were used in the PW and DW, respectively. Surface dose was measured at 1 cm, 3 cm, and 5 cm from the center of the field size, respectively. According to the results, FIF showed lower surface dose compared to PW and DW regardless of the energy of the X-ray beam, wedge angle, and dose measurement point. Since FIF could reduce the radiation dose in periphery of the field size in breast cancer treatment, it is expected to be able to reduce the secondary damage caused by the radiation beam as well as to obtain a uniform dose distribution on the target.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

Survival and Complication Rate of Radiation Therapy in Stage I and II Carcinoma of Uterine Cervix (병기 I, II 자궁 경부암에서 방사선치료 후 생존율 및 합병증 분석)

  • Ma, Sun-Young;Cho, Heung-Lea;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.349-357
    • /
    • 1995
  • Purpose : To analyze survival rate and late rectal and bladder complication for patients with stage I and II carcinoma of uterine cervix treated by radiation alone or combined with chemotherapy Materials and Methods : Between November 1984 and December 1993, 127 patients with stage I and II carcinoma of uterine cervix treated by radiation alone or combined therapy of radiation and chemotherapy. Retrospective analysis for survival rate was carried out on eligible 107 patients and review for complication was possible in 91 patients. The median follow-up was 47 months (range 3-118) and the median age of patiens was 56 years (range 31-76). 26 patients were stage IB by FIGO classification, 40 were stage IIA and 41 were stage IIB. 86 cases were treated by radiation alone and 21 were treated by radiation and chemotherapy. 101 patients were treated with intracavitary radiation therapy (ICRT), of these, 80 were received low dose rate (LDR) ICRT and 21 were received high dose rate (HDR) ICRT. Of the patients who received LDR ICRT, 63 were treated by 1 intracavitary insertion and 17 were underwent 2 insertions And we evaluated the external radiation dose and midline shield. Results : Actuarial survival rate at 5 years was $92{\%}$ for stage IB, $75{\%}$ for stage IIA, $53{\%}$ for stage IIB and $69{\%}$ in all patients Grade 1 rectal complications were developed in 20 cases ($22{\%}$), grade 2 were in 22 cases ($24{\%}$). 22 cases ($24{\%}$) of grade 1 urinary complications and 17 cases ($19{\%}$) of grade 2 urinary complications were observed But no patient had severe complications that needed surgical management or admission care. Maximum bladder dose for the group of patients with urinary complications was higher than that for the patients without urinary complications (7608 cGy v 6960cGy. p<0.01) Maximum rectal dose for the group of patients with rectal complications was higher than that for the patients without rectal complications (7041cGy v 6269cGy, p<0.01). While there was no significant difference for survival rate or bladder complication incidence as a function of dose to whole pelvis, Grade 2 rectal complication incidence was significantly lower for the patients receiving less than 4500cGy ($6.3{\%}$ v $25.5{\%}$, p<0.05). There was no significant differance between HDR ICRT group and LDR ICRT group for survival rate according to stage, on the other hand complication incidence was higher in the HDR group than LDR group, This was maybe due to different prescription doses between HDR group and LDR group. Midline shield neither improved survival rate nor decreased complication rate. The number of insertion in LDR ICRT group did not affect on survival and compication rate. Conclusion : In stage I and II carcinoma of uterine cervix there was no significant differance for 5 year survival rate by radiation therapy technique. Rectal complication incidence was as a function of dose to whole pelvis and there were positive correlations of maximum dose of rectum and bladder and each complication incidence. So we recommand whole pelvis dose less than 4500cGy and maximum dose of rectum and bladder as low as possible.

  • PDF

Radiation Dose of Lens and Thyroid in Linac-based Radiosurgery in Humanoid Phantom (선형가속기형 방사선수술시 인형 팬텀에서 수정체 및 갑상선 선량)

  • Kim, Dae-Yong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.517-529
    • /
    • 1998
  • Purpose : Although many studies have investigated the dosimetric aspects of stereotactic radiosurgery in terms of target volume, the absorbed doses at extracranial sites: especially the lens or thyroid - which are sensitive to radiation for deterministic or stochastic effect -have infrequently been reported. The aim of this study is to evaluate what effects the parameters of radiosurgery have on the absorbed doses of the lens and thyroid in patients treated by stereotactic radiosurgery, using a systematic plan in a humanoid phantom. Materials and Methods : Six isocenters were selected and radiosurgery was planned using the stereotactic radiosurgery system which the Department of Therapeutic Radiology at Seoul National University College of Medicine developed. The experimental radiosurgery plan consisted of 6 arc planes per one isocenter, 100 degrees for each arc range and an accessory collimator diameter size of 2 cm. After 250 cGy of irradiation from each arc, the doses absorbed at the lens and thyroid were measured by thermoluminescence dosimetry. Results : The lens dose was 0.23$\pm$0.08$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the lens and was 0.76$\pm$0.12$\%$ of the maximum dose for each isocenter when the exit beam passed through the lens. The thyroid dose was 0.18$\pm$0.05$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the thyroid and was 0.41$\pm$0.04$\%$ of the maximum dose for each isocenter when the exit beam Passed through the thyroid. The passing of the exit beam is the most significant factor of organ dose and the absorbed dose by an arc crossing organ decides 80$\%$ of the total dose. The absorbed doses of the lens and thyroid were larger as the isocenter sites and arc planes were closer to each organ. There were no differences in the doses at the surface and 5 mm depth from the surface in the eyelid and thyroid areas. Conclusion : As the isocenter and arc plane were placed closer to the lens and thyroid, the doses increased. Whether the exit beams passed through the lens or thyroid greatly influenced the lens and thyroid dose. The surface dose of the lens and thyroid consistently represent the tissue dose. Even when the exit beam passes through the lens and thyroid, the doses are less than 1$\%$ of the maximum dose and therefore, are too low to evoke late complications, but nevertheless, we should try to minimize the thyroid dose in children, whenever possible.

  • PDF