• Title/Summary/Keyword: 납 동위원소

Search Result 46, Processing Time 0.017 seconds

Development of soil certified reference material for determination of the hazardous elements (유해원소 측정용 토양 인증표준물질 개발)

  • Kim, In-Jung;Min, Hyung-Sik;Suh, Jung-Ki;Han, Myung-Sub;Lim, Myung-Chul;Kim, Young-Hee;Shin, Sun-Kyoung;Cho, Kyung-Haeng
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • A certified reference material (CRM) of KRISS 109-03-SSD was developed for the analysis of hazardous elements in soil. The target elements were As, Cd, Cr, Cu, Hg, Ni, Pb, Zn being regulated by the Soil Environment Conservation Act. Starting material was collected from tailing dump of an unworked tungsten mine at Sangdong (Gangwon-do, Korea). The starting material under-went through a series of fabricating process steps of screening, drying, grinding, sieving, blending, bottling, sterilization and was certified according to the ISO Guide 35. Isotope dilution-inductively coupled mass spectrometry (ID-ICP/MS) and instrumental neutron activation analysis (INAA) were used for the measurement. Homogeneity was tested according to ISO 13528 annex B. The certified values were determined using the results from two different methods or from two independent measurements using a method. Finally, certified values of seven elements of arsenic, cadmium, chromium, copper, lead, nickel and zinc were determined. Mercury did not satisfied the criteria of homogeneity and the result would be provided for information only, together with iron and tungsten. It was also studied, the extractable fraction of elements by aqua regia according to the ISO 11466 protocol being frequently studied for the purpose of environmental monitoring. It was performed as a inter-laboratory study by 6 laboratories of a public institute and universities. Standard deviation among the laboratories was much bigger than the uncertainty of the certified value. The result of inter-laboratory study on the extractable fraction will be provided for information, only.

Conservation and Analysis of Goryeo-era Coins in Collection of the National Museum of Korea -Donggukjungbo, Dongguktongbo, Haedongtongbo, Haedongjungbo, Samhanjungbo- (국립중앙박물관 소장 고려시대 동전의 보존과 분석 -동국중보(東國重寶), 동국통보(東國通寶), 해동통보(海東通寶), 해동중보(海東重寶), 삼한중보(三韓重寶)-)

  • Jeon, Hyosoo;Kang, Hyungtae;Ahn, Jooyoung
    • Conservation Science in Museum
    • /
    • v.9
    • /
    • pp.17-29
    • /
    • 2008
  • We conducted preservation treatment for 25 pieces of coins of Goryeo era in collection of the National Museum of Korea. Object coins are 5 kinds of 'Donggukjungbo', 'Dongguktongbo', 'Haedongtongbo', 'Haedongjungbo', 'Samhanjungbo'. As it is worried that if all chlorides able to make bad influence on reclics are removed, letter and chape of coin can be damaged, they were removed partially. To date, inscribed letter form of Dongguktongbo is known as more than 6 types, and as a result of interpreting X-ray photos, 3 types of inscribed letters were identified by this study. Bronze rust acquired in the process of removing rust on coins, origin of materials for coin was assumed through lead isotope ratio analysis. Latest tendency is that diverse scientific analyses are conducted based on bronze rust.

Quantitative Analysis and Archaeometric Interpretation for Molten Glass and Bronze Materials within Baekje Crucibles from the Ssangbukri Site in Buyeo, Korea (부여 쌍북리유적 출토 백제 도가니 내부 유리 및 청동 용융물질의 정량분석과 고고과학적 해석)

  • Lee, Chan-Hee;Park, Jin-Young;Kim, Ji-Young
    • Journal of Conservation Science
    • /
    • v.26 no.2
    • /
    • pp.157-169
    • /
    • 2010
  • This study focused on the material characteristics and archaeometric relationship between the molten glass and bronze materials within the crucibles and gilt-bronze Bodhisattva statue excavated from the Ssangbukri site in Buyeo, Korea. Yellowish green to red brown vitreous material in the crucibles was identified as lead glass which contained scarce amount of BaO, and low $Al_2O_3$ and CaO. Metallic molten material was identified as bronze of copper-tin-lead alloy with low amount of impurities that indicated well-refined materials. Also, cassiterite was used for raw metal ore of tin. The Bodhisattva statue consisted of major copper with trace impurities in the core metal, and gold amalgam in the gilded layer. Though lead isotopic analysis showed contradictory results in each lead glass, bronze and Bodhisattva statue that required further examination, it could be stated that the statue was made in the Ssangbukri site based on the high-level technical skills of bronze production.

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation (GATE 시뮬레이션을 이용한 I-131 영상의 산란 및 격벽통과 보정방법 연구)

  • Jung, Ji-Young;Kim, Hee-Joung;Yu, A-Ram;Cho, Hyo-Min;Lee, Chang-Lae;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2009
  • Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.

  • PDF

The Characteristics of Green-glaze on Bricks from the Sacheonwang Temple Site, Gyeongju (경주 사천왕사지 녹유전의 녹유 특성 연구)

  • Lee, Han Hyoung;Jeong, Min Ho;Moon, Eun Jung;Park, Ji Yeon;Kim, Soo Kyung;Choi, Jang Mi;Han, Min Su
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.112-131
    • /
    • 2011
  • This article reports the results of scientific analysis using SEM-EDX, XRD, TG/DTA, performed on 5 green glaze samples of the brick and roofing tile excavated from the Sacheonwang temple site in Gyeongju in order to verify the chemical compositions and melting temperature. The glaze samples on 2 clay statues have similar chemical composition (PbO 74~81%, $SiO_2$ 14~18%) and melting temperature range ($970{\sim}1070^{\circ}C$), whereas the 2 tiles of goblin's face and 1 rhomb brick have different characteristics. Sample SC 003 (made of PbO 63~67%, $SiO_2$ 25~28%), one of the tiles of goblin's face, shows low melting temperature range (below $970^{\circ}C$), and sample SC 004 (composed of PbO 64~70%, $SiO_2$ 19~25% and melting point $970{\sim}1070^{\circ}C$), the other tile of goblin's face, shows different chemical characteristics compared with 2 clay statues. The green glaze on rhomb brick shows different composition compared with all the others from Sacheonwang temple site in that it does not show any impurity elements other than the main components (PbO 87~88%, $SiO_2$ 12~13%) with very low melting temperature range ($750{\sim}770^{\circ}C$). Surprizingly, the chemical and optical characteristics of this green-glaze on rhomb brick are very similar to that on the bricks from Yeongmyo temple site, Gyeongju. The above results indicate that raw material and manufacturing method are not same for 5 green-glaze samples from Sacheonwang temple site and therefore suggests that further study on the provenance of raw material such as lead isotope analysis is necessary. Our work will provide basic data for future reproduction study of green glazed brick of Sacheonwang temple site, Gyeongju and will also serve as a reference data for the study of raw material and manufacturing method of green glaze from other sites of cultural assets.