• Title/Summary/Keyword: 납형

Search Result 29, Processing Time 0.029 seconds

Full mouth rehabilitation of the patient with severely worn dentition and limited vertical dimension (심한 치아 마모와 수복공간 부족을 보이는 환자에서의 완전 구강회복 증례)

  • Yang, Min-Seong;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Park, Ji-Man;Yi, Yu-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.91-99
    • /
    • 2022
  • Severely worn dentition causes various complications such as loss of tooth structure, discoloration, pulp complications and loss of function and aesthetics. In this case, the patient showed particularly severe attrition in the anterior teeth and lack of space for restoration. The amount of vertical dimension was determined based on the diagnostic wax up, and the patient's adaptation was evaluated by using a removable occlusal splint for 6 weeks. Thereafter, the coordination of the muscular nervous system, aesthetics, temporomandibular joint were re-evaluated for 3 months by restoring the fixed provisional restoration. Through the above treatment process, the final restoration was completed with full mouth fixed prosthesis using monolithic zirconia, and functionally and aesthetically stable results were obtained.

Fixed prosthesis restoration in edentulous patient fully implanted without considering definitive prosthesis: A case report (최종 보철물에 대한 고려 없이 전악 임플란트 식립된 환자의 고정성 보철 수복 증례)

  • Chun, Young-Hoon;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.427-435
    • /
    • 2017
  • The most important factor in the treatment of fully edentulous patients using implants is the shape of the definitive prosthesis. After the shape of the definitive prosthesis is determined, residual bone analysis and selection of the implant type, number and position should be followed. In this case, for restoration of an edentulous patient fully implanted (except the maxillary right lateral incisor) without considering definitive prosthesis, facial esthetics and possibility of fixed type prosthesis were evaluated using complete denture. It was determined that the fixed type prosthesis was possible. Implants that could not be used for the definitive prosthesis were excluded from the treatment plan and fixed type provisional restorations were fabricated. After four months of provisional restorations, the patient showed stable occlusion and esthetic satisfaction. Definitive prosthesis was made of zirconia using CAD/CAM (computer aided design and computer aided manufacturing). The results were satisfactory during the 3 months of follow-up period after termination of treatment.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

3D printed surveyed restoration and metal framework in removable dentures: A case report (3D 프린팅 된 서베이드 금관과 금속 프레임워크를 이용한 양악 가철성 의치 수복 증례)

  • Song Yi Park;Sang-Won Park;Chan Park;Woohyung Jang;Kwi-Dug Yun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.153-159
    • /
    • 2023
  • Computer-aided design-computer-aided manufacturing technology has been widely used in the manufacture of fixed prostheses including implants, but in the case of removable dentures, the analog method is still being used due to the errors such as a lack of fusion and over-fusion in selective laser meting process. With the recent development of CAD software, virtual surveying and framework design are made possible, and the designed file can be manufactured by milling or 3D printing. It replace the analog method of waxing and denture curing process and also can reduce the production time and cost. Therefore, this case is reported because good clinical results were obtained by digitally surveying on CAD software to produce a surveyed metal restoration and framework on maxillary and mandibular removable dentures.

Full mouth rehabilitation with fixed prostheses by increased vertical occlusal dimension using 3D printed splint in a patient with excessive tooth wear (과도한 치아 마모 환자의 3D 프린팅 교합안정장치를 이용한 수직 교합 고경 증가를 동반한 고정성 보철물 전악 수복 증례)

  • Se-Young Kim;Soo-Yeon Shin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.215-226
    • /
    • 2023
  • Severe wear of the anterior teeth facilitates the loss of anterior guidance, which protects the posterior teeth from wear during excursive movement. Additionally, when treating patients with collapsed occlusion due to multiple tooth loss and tooth wear, it is important to determine the presence of vertical dimension loss through accurate clinical and radiographic examinations and diagnostic wax-up. The patient of this case is a 44-year-old female patient who complained of overall tooth wear and loss of posterior teeth due to bruxism and clenching habits, visited the hospital with the address of restoring masticatory function and improving aesthetic appearance through prosthetic treatment. Through model analysis and diagnostic wax-up, an increase in vertical dimension was determined, and full mouth restoration with fixed prostheses was planned. The degree of adaptation to the vertical dimension was confirmed step by step using an occlusal splint designed with CAD (Computer aided design) software and 3-D (3-Dimensional) printed, and then restored with provisional restoration and after a 4-month adaptation period, the entire dentition was restored with metal ceramic crowns and implants. Through this procedure, satisfactory treatment results were obtained in terms of function and aesthetics.

Oral rehabilitation of a patient with collapsed occlusal plane resulting from loss of posterior teeth (구치부 상실로 인해 교합 평면이 기울어진 환자에서 임플란트를 이용한 구강 회복 증례)

  • Jinwoo Han;Jae-Seung Chang;Se-Wook Pyo;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.165-173
    • /
    • 2024
  • Restoring lost teeth is very important in terms of both function and aesthetics. If tooth loss occurs in the posterior region and the loss of support is persistent, it may cause a gradual shift in the position of the mandible and a change in occlusion. This clinical case attempted to restore support for the posterior teeth with a fixed prosthesis using implants in a patient whose opposing teeth were erupted and the occlusal plane collapsed due to long-term loss of the maxillary left posterior teeth and mandibular right first molars. To correct the occlusal plane of remaining dentition, wax-up of maxillary left posterior teeth was duplicated with acrylic resin and placed on maxilla. Surgical template for implant placement were fabricated using digital technology. After the support of the posterior teeth was restored with the placement of the implant, stable occlusion with temporary restorations was observed for a sufficient time. Afterwards, monolithic zirconia prosthesis was placed on the patient to ensure functional and aesthetic improvement.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.