• Title/Summary/Keyword: 난시안

Search Result 110, Processing Time 0.024 seconds

The Study of Eye Re fraction State on Old Age in Je-ju islands (제주도 지역 노인의 굴절이상에 대한 연구)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • The purpose of this study was to provide the accurate information on improvement of visual life by examining old age's eye refraction state and investigating distribution of ametropia in old age. The test was performed the visual acuity test by object and subject methods to over 60 years of age. The results were as follows: 1. As the result to investigate the inconvenience degree of visual life, the subjects appealed 81% for very inconvenience and 14% for a little inconvenience. 5% of them didn't feel any inconvenience in visual life. 2. The eye types were 1.7% for emmetropia, 10% for myopia, 74.7% for hyperopia, and 13.6% mixed astigmatism, respectively. 3. The axis of astigmatisms were 65% positive for indirect astigmatism, 8% for direct astigmatism, and 27% for oblique astigmatism, respectively.

  • PDF

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

Difference between Manifest Refraction (MR) and Cycloplegic Refraction (CR) with Age and Myopic Value (연령과 근시도에 따른 현성굴절검사와 조절마비굴절검사의 비교)

  • Jeong, Woo-Jae;Kang, Ji-Hun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate difference between manifest refraction (MR) and cycloplegic refraction (CR) with age and myopic value. Methods: Manifest and cycloplegic refractions were carried out on the patients of 229 myopic patients ($25.3{\pm}11.9$ years old). Results: The average results from a pre- and a postcycloplegic refraction showed a reduction of 0.19 D in myopia, 0.02 D in astigmatism and $1.85^{\circ}$ in astigmatism direction. Change of myopic value was higher in 30~40 age. Total 73 eyes of 229 patients who showed 0.50 diopter (D) in spherical, and a high degree of myopia group showed a higher discrepancy rate. Conclusions: The results found in the comparison of the value of the manifest refraction and cycloplegic refractions showed changes of myopic value was not significant with age of patient, but the group of high degree of myopia showed higher discrepancy rate.

The Effect of Myopic Degree on the Change of Higher-order Aberrations Induced by Aging (근시도가 나이에 따라 유발되는 고위수차의 변화에 미치는 영향)

  • Ryu, Nam-Yul;Park, Kyoung-Hee;Kim, So-Ra;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.353-362
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the change of higher-order aberrations induced by aging and the effect of myopic degree on the correlation between age and higher-order aberrations. Methods: The higher-order aberrations in 931 eyes aged from 20 to 60 were measured by using a LADARWave device employing Hartmann-Shack system to analyze the effect of myopic degree measured by manifest refraction test on higher-order aberrations. Results: Coma and vertical coma aberrations were significantly decreased by the increase of myopic degree while vertical astigmatic aberration was significantly increased. The correlations of age and coma, vertical coma, spherical, vertical trefoil, horizontal trefoil, vertical astigmatic, horizontal astigmatic and vertical tetrafoil aberrations depended on the myopic degree, except for horizontal coma and horizontal tetrafoil aberrations. Conclusions: It is suggested to consider the myopic degree for the refractive correction including the laser surgery based on the present result that higher-order aberrations are affected by the myopic degree.

Repeatability Assessment of Autorefractor and Accuracy Analysis of Refraction Measurements by Fourier Analysis (자동굴절검사기의 신뢰성 평가 및 Fourier analysis에 의한 정확도 분석)

  • Kim, Tae-Hun;Ye, Ki-Hun;Kim, Jae-Kwang;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.29-36
    • /
    • 2008
  • Purpose: We have evaluated both the reliability and accuracy of refractive measurement from autorefractor by comparing with subjective refraction data. Methods: Measurements of refractive error were performed on 198 eyes of 99 subjects in noncycloplegic condition. Also we analyzed refraction results and evaluated repeatability and accuracy of subjective refraction and autorefraction. Furthermore we analyzed accuracy of autorefractor by Fourier analysis. Results: Reliability coefficient of the autorefraction for the right eye were determined to by 0.993, 0.974 and 0.925 respectively, in the spherical, cylinderical component and cylinderical Axis. Also, the reliability coefficient of the autorefraction for the left eye were found to be 0.991, 0.948 and 0.886, respectively, in the spherical, cylinderical component and cylinderical Axis. From the Fourier analysis no statistically significant differences in $J_{0}$ component were found between the auto and subjective refraction measurements (p>0.05) whereas difference of refractive power of $J_{45}$ component when compared with the subjective refraction were -0.019, -0.164. Conclusions: We conclude that autorefractormeter can be effectively used to measure the refractive power within the error limits.

  • PDF

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

Effect of Spectacles Correction on the Improvement of Visual Acuity in Hyperopic Amblyopia (원시성 약시에서 안경교정에 의한 시력개선 효과)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.95-106
    • /
    • 2007
  • The purpose of this study was to investigate effect of spectacle correction therapy instead of occlusion therapy for refractive amblyopia treatment. Spectacle correction were prescribed to give the same effect as a occlusion therapy by under correction for normal eye and there was no additional treatment but only spectacle correction for hyperopic amblyopia. The results can be summarized as follows: 1. In hyperopic amblyopia after correction, initial visual acuity($Mean{\pm}SD$) was $0.36{\pm}0.13$ and final visual acuity($Mean{\pm}SD$) was $0.82{\pm}0.23$. 2. Regardless with age, there was significant differences between initial acuity and final acuity, it shows improvement in visual acuity after spectacle correction treatment. 3. Initial correction age did not influence the length of treatment and success rate of treatment, so that ambyopia correction effect not related with age. 4. Compared with initial visual acuity with final visual acuity, initial visual acuity was in proportion to final visual acuity. 5. Incidence was higher in hyperopia and hyperopic astigmatism than myopia and myopic astigmatism in refractive amblyopia group and the therapy was more effective for hyperopia and hyperopic astigmatism than myopia and myopic astigmatism. 6. Treatment was effective even for children who is older than 8 years.

  • PDF

A Study of the Refraction State on Spherical Lens and Aspherical Lens (구면렌즈와 비구면렌즈를 착용한 굴절이상안의 비교에 관한 연구)

  • Kang, Hyang Nyeo;Kim, Jin Koo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.43-47
    • /
    • 2001
  • The classifying distribution by the Spherical lens and Aspherical lens was middle myopic, middle myopic astigmatism middle mixed astigmatism compared. The refractive erroeye spherical lens were S-3.00 ~ S-6.00Dptr for the middle myopic 16%, S-6.00Dptr 19%, S-3.00C-0.50(90.180) ~ S-6.00C-2.00Asix(90.180)57%, S-3.00C+0.50(90.180) ~ S-6.00C+2.00Axis(90.180) 8% for the compound myopic astigmatism. Aspherical lens were S-3.00 ~ S-6.00Dptr for the middle myopic 31%, S-6.00Dptr 36%, S-3.00C-0.50(90.180) ~ S-300C-2.00Axis(90.180) 21%, S-3.00C+0.50(90.180) ~ S-3.00C+2.00Axis(90.180)12%, for the compound hyperopic astigmatism.

  • PDF

A Clinical Study on Presbyopia in Wearing the Near Spectacle for the First Time (근용 안경을 최초 장용하는 노안에 대한 임상적 연구)

  • Yoo, Jong-Sook;Lim, Hyeon-Seon;Lee, Soo-Cheon;Hwang, Jung-Hee;Kim, Hyo-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This research measured the near addition powers of presbyopia in wearing the near spectacle for the first time. Methods: We evaluated age, sex, working group, spherical power and cylindrical power and measured the power of refractive error performed the both eyes (310 eyes) of 155 subjects subjectively noncycloplegic and power of addition using the cross cylinder method. Results: There were measured the near addition powers in the range of +0.75D ~ +1.75D. In case of the average addition, they were measured with +1.06D in subjects under 43 years of age, +1.08D in 44 to 46 years, +1.23D in 47 to 49 years and +1.46D in over 50 years of age. The average age in subjects was 47.6 years old and 74 male, 81 female, 71 near sighted working group and 83 far sighted working group. Conclusions: Near addition was correlated with age, working group and cylindrical power (P<0.05, P<0.05, P<0.05).

  • PDF