• Title/Summary/Keyword: 난방 시스템

Search Result 683, Processing Time 0.026 seconds

Study on Thermal Performance of Energy Textile in Tunnel (터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구)

  • Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1907-1914
    • /
    • 2013
  • Textile-type heat exchangers installed on the tunnel walls for facilitating ground source heat pump systems, so called "energy textile", was installed in an abandoned railroad tunnel around Seocheon, South Korea. To evaluate thermal performance of the energy textile, a series of long-term monitoring was performed by artificially applying daily intermittent cooling and heating loads on the energy textile. In the course of the experimental measurement, the inlet and outlet fluid temperatures of the energy textile, pumping rate, temperature distribution in the ground, and air temperature inside the tunnel were continuously measured. From the long-term monitoring, the heat exchange rate was recorded as in the range of 57.6~143.5 W per one unit of the energy textile during heating operation and 362.3~558.4 W per one unit during cooling operation. In addition, the heat exchange rate of energy textile was highly sensitive to a change in air temperature inside the tunnel. The field measurements were verified by a 3D computational fluid dynamics analysis (FLUENT) with the consideration of air temperature variation inside the tunnel. The verified numerical model was used to evaluate parametrically the effect of drainage layer in the energy textile.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

A Study on the Thermal Characteristics of Jeju type Ground Heat Exchanger for Ground Source Heat Pump System applied to Jeju Island (제주도에 설치된 지열 열펌프 시스템용 제주형 지중열교환기의 열특성 연구)

  • Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.32-38
    • /
    • 2020
  • This study summarizes test methods and evaluation methods for examining the thermal characteristics of Jeju-type ground heat exchangers (GHXs) installed on Jeju Island, and analyzes the ground temperature and thermal characteristics of ground heat exchangers installed in various regions by using thermal response tests (TRT). Jeju Island is composed of volcanic rock layers, and the groundwater flow is well developed. A Jeju-type GHX can be installed up to 30 m from groundwater level after drilling a borehole. The ground heat exchanger has a structure in which several pipes are inserted into the borehole. In order to examine the characteristics of the Jeju-type GHX, tests were conducted on ground heat exchangers installed in four places on Jeju Island (Pyoseon, Jeju, Namwon, and Hallym). As a result of the analysis of the Jeju-type ground heat exchanger, the ground circulating water temperature stabilized according to the heat injection, depending on the installed location, and was formed within one to three hours. The ground heat exchanger capacity in Hallym was highest at 73.4 kW (cooling) and 82.8 kW (heating), and the Jeju-type calculation was lowest at 34.1 kW (cooling) and 23.3 kW (heating).

Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors (광센서를 이용한 제상제어 방법에 대한 타당성 검토)

  • Jeon, Chang-Duk;Kim, Dong-Seon;Lee, Seung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3389-3395
    • /
    • 2014
  • Conventional methods, such as the clock time control method and temperature difference control method, for defrost control often encounter mal-defrost and a waste of energy. Therefore, a more efficient method is needed to control defrosting precisely. A photoelectric sensor unit consisting of an emitter and a collector was installed in the front of outdoor heat exchanger. Accurate defrost control was performed by monitoring and using the change in output voltage according to the presence of frost. In this study, experiments were performed to determine if the performance and characteristic curves obtained using the clock time control method can be reproduced using a photoelectric sensor under the heating and defrosting capacity test condition described at KS C 9306. The output voltage of the phototransistor (receiver) and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger, were compared. The results showed that photoelectric sensors can be used as a defrost control method. On-off control timing of the clock time defrosting method was in good agreement with those predicted by the output voltage of the photoelectric sensor.

Indepth Study of Numerical Heat Transfer and Fluid Flow for Energy Saving of Greenhouse (시설하우스 에너지 절감을 위한 열유동 수치 해석 심층 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Choi, Jun-Ho;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.466-471
    • /
    • 2007
  • The purpose of study is to obtain basic but important information for the operation of the greenhouse facility located in the suburb of town. Special emphasis is given on the aspect of energy saving method, which can be easilyapplicable in a practical sense. For this end numerical calculation has been made systematically in order to increase the energy efficiency by the evaluation of the temperature distribution in greenhouse. Major parameters considered are primarily the overall shape of greenhouse together with the various conditions of baffle installion inside greenhouse. Further, the performance of heating system is also carefully compared each other for a number of typical arrangements of heating duct. The performance of the computer program developed in this study is evaluated by the observation of the famous fluid trapping phenomenon occurred in staggered baffle condition in the enclosure of greenhouse. Based on the this study, a number of useful conclusions can be drawn, that is, the installation of baffles are quite effective in energy saving method with a minor modification of facility. Also, it is found that the change of the heating duct system can contribute significantly to the uniform temperature distribution in greenhouse. Further other findings obtained by numerical calculation were not only physically consistent and meaningful but also useful for the determination of optimum condition of practical operation of greenhouse.

Design and Implementation of a Power-Saving Management System using Intelligent Scheduler based on RFID/USN Technology (RFID/USN 기술 기반의 지능형 스케줄러를 이용한 절전관리 시스템 설계 및 구현)

  • Jeong, Kyu-Seuck;Choi, Sung-Chul;Jeong, Woo-Jeong;Kim, Tae-Ho;Kim, Jong-Heon;Seo, Dong-Min;Park, Yong-Hun;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.64-76
    • /
    • 2009
  • Recently, the ubiquitous environment and the practical technology associated with it become more popular topic along with the rapid development of wireless technologies. The necessity of the automated system based on the ubiquitous environment has been increasing when the concept of the ubiquitous is integrated into the fields of existing IT. Also, the necessity of formulating a power-saving plan on large buildings and public institutions is gathering strength because of a raise in exchange rates and high oil prices. In this paper, to efficiently manage the power consumption of the electronic machine such as electric lights, electric heaters, and air conditioners in a building, power-saving manage- ment system using RFID/USN technologies is proposed. Proposed system controls the electric machine and monitor it's condition by RFID and collects the real time information about the surrounding and the power consumption of the electric machine by USN. Especially, proposed system analyzes the real time information and supports the intelligent scheduler with the best power-saving. Finally, this paper shows the difference between proposed system and existing system and establishes thereality of our system through experiments in variety environments.

A Study on Performance Characteristics of Heat Pump System on Cooling Mode for Light-duty Commercial Electric Vehicles (EV 상용차용 히트펌프 시스템 냉방 운전 특성에 관한 연구)

  • Jeon, Hanbyeol;Kim, Jung-Il;Won, Hun-Joo;Lee, Ho-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.69-75
    • /
    • 2019
  • The cooling performance of heat pump system for light-duty commercial electric vehicle was evaluated experimentally. The cooling performance characteristics of the heat pump for light-duty commercial electric vehicles were evaluated by varying the temperature, flow rate of chiller coolant, and electric compressor speed, under the exterior air temperature of 35 ℃ and interior air temperature of 25 ℃. Increasing the compressor speeds decreased the cooling system efficiency by 16.4 % on average with the cooling capacity increasing by 8.0 % on average and the compressor work increasing by 27% on average. To use waste heat from the coolant to chill power electronic components, such as the motor and inverter, a chiller was installed to transfer heat between the coolant and refrigerant. Increasing the temperature of the chiller coolant from 35 ℃ to 55 ℃ decreased the efficiency by 18.2 % on average due to higher condensing heat source. Increasing the coolant flow rate from 10 liter/min to 20 liter/min did not affect the cooling capacity of the system due to a similar total condensing heat transfer rate at the chiller and the exterior heat exchanger. In future works, heating performance will be investigated by varying the operating conditions to use the chiller's waste heat with an improvement of heating capacity.

A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House (공동주택의 환기시스템별 에너지성능 비교 분석)

  • Kim, Gil-Tae;Chun, Chu-Young;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.215-220
    • /
    • 2015
  • The purpose of this study was to comparative analyses of energy performance in apartment houses adopted window frame-type natural ventilation, under-floor air distribution ventilation and heat recovery ventilation. As the object of energy simulation, the three type ventilation system with area of $84m^2$ was selected in apartment house. As a result, when the ECO2 simulation was performed, the 1st requirement quantity per annual were $159.9kWh/m^2yr$(CASE1, Natural Ventilation), $179.7kWh/m^2yr$(CASE2, Under-floor Air Distribution Ventilation) and $161.0kWh/m^2yr$(CASE3, Heat Recovery Ventilation).

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열회수성능 분석)

  • 서원명;윤용철;강종국
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.212-222
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. The experimental heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas flue, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amounts by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air tubes and exhaust air passages crossing the tubes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through flue.

  • PDF

Efficiency Analysis of the HVAC system in the School Facilities Using the Geothermal Energy -Focused on the energy consumption- (지열을 이용한 학교시설의 냉·난방시스템 효율성분석 -에너지 소비량을 중심으로-)

  • Park, Dong-Soon;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.25-52
    • /
    • 2007
  • This paper is focused on the economical efficiency of the geothermal heat pump system in school. As the importance of problems of environment and energy becomes larger, the development and distribution of energy-saving technology in the whole nation has become influential. This paper is intended, targeting on school buildings scattered all over the country, to evaluate the introduction and possibility of a terrestrial heat system which is in the first stage of introduction in the country, through energy consumption and efficiency in case where a terrestrial heat system is introduced. To do that, the author performed a qualitative analysis of the heat pump system using various terrestrial heat energy and the system introduced to existing school buildings and, through the analysis, made tentative evaluation on the most environment-friendly and energy saving type system. Also, the author performed simulation analysis using a currently typical school building standard and, on the basis of this result, conducted efficiency analysis of various heat pump systems. The conclusion according to synthetical analysis & evaluation can be summarized as follows. In case a heat pump system is introduced to a school building, it was deemed the investment in the early stage would increase, but the investment could be collected within 5~6 years through reduction of large operation expenses. Also, it was analyzed in case of terrestrial heat contracted heat mode using midnight electric power among heat pump systems, not only early investment but also operation expenses could be reduced to a great extent. Accordingly in case the system using terrestrial heat energy is applied to the school buildings that are to be newly built or repaired in the future, it will provide an object-lesson to students as well as contributing to energy saving.

  • PDF