• Title/Summary/Keyword: 난방 도일

Search Result 124, Processing Time 0.022 seconds

Heating and cooling properties in cultivation room and cultural characteristics of oyster mushroom according to type of air exchange (외부공기 유입방식에 따른 느타리버섯 생육실의 온도변화 및 자실체의 생육특성)

  • Jang, Myoung-Jun;Lee, Yun-Hae;Ju, Young-Cheol
    • Journal of Mushroom
    • /
    • v.11 no.4
    • /
    • pp.214-218
    • /
    • 2013
  • This study was carried out to find out suitable input method for air exchange about bottle cultivation of oyster mushroom. There was no difference of average temperature in cultivation room, but T1(direct introduction of outside air) was higher than T2(heat exchanger) and T3(air buffer) in the standard deviation. The ratio of cooling operating was the highest in August and in the descending order, T1 54%, T3 43%, T2 33%. At ratio of energy reduction, T2 and T3 were higher than T1. The operating ratio of heater was highest in January and in the descending order, T1 53%, T3 37%, T2 30%. At ratio of energy reduction(%), T2 and T3 were higher than T1 similar to result of cooling operating. Therefore there were largest in August about Cooling Degree-Hour and in January about Heating Degree-Hour. And fruitbody yields quality was excellent in T2 and T3 than T1. The suitable effective type of air exchange in oyster mushroom cultivation are heat exchange and air buffer system.

Inventory of Carbon Dioxide Emission in Carbon Cycle Community (The case study on Gyeongbuk Bonghwa-gun Chunyang-myeon Seobyeok-ri) (탄소순환마을의 이산화탄소배출량 조사연구 (경상북도 봉화군 춘양면 서벽리를 중심으로))

  • Kim, Hyo-Jin;Byun, Woo-Hyuk;Lim, Min-Woo;Park, Won-Kyoung;Kim, Min-Su
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.4
    • /
    • pp.597-602
    • /
    • 2010
  • The most basic matter to establish forest carbon circulation village is statistic on greenhouse gas emissions. But currently, although there is statistic on greenhouse gas emissions in the level of city or province, there is not statistic on greenhouse gas emission in village unit. According to the results, The model area is located in Seobyeok-ri, Chunyang-myeon, Bonghwa-gun, Gyeongsangbuk-do, the total $CO_2$emissions caused by energy used in the model area was $1,755tCO_2$. Heating accounts for 55% of total emissions followed by 23% for power and 22% for vehicles. The model area emitted $572tCO_2$ due to rice growing and livestock raising, accounting for approximately 24.5% of total $CO_2$ emissions. It is expected that a reduction of as much as $884tCO_2$ emissions will be made from the current $964tCO_2$ to a level of 1/12th that amount, or $80tCO_2$ by replacing heating energy currently used in the model area with wood bioenergy such as wood chips or pellets. In addition, carbon emission reduction is expected for both heating and power by replacing the power consumption in houses, buildings, and street lights with solar power.

A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention (축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구)

  • Lee, Jae kyung;Seo, Seong Hyeon;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.553-564
    • /
    • 2021
  • This study analyzed the the risk of halogen lamp for pigsty heating and its fire prevention. Halogen lamps are used for keeping warm in pen because of their excellent economy and convenience. However, there is a high risk of fire due to poor safety management and exposure to animal movements. In fact, after exploring old pigsty and cattle shed, it was easy to confirm that they were exposed to fire risks. We noted this point and studied the possibility of fire by experiment due to combustible contact with halogen lamp and carelessness in use. The experiment was conducted under conditions similar to the actual use environment. After installing halogen lamps to the height used in actual pen, the temperature change was observed with infrared camera with straw, sawdust and rice husks on the floor. And assuming abnormal conditions, the experiment was also conducted under conditions the lamp dropped on the floor or combustible material came into contact with the glass tube inside the lamp. If halogen lamps were used in normal condition, there was no risk of fire. However, in abnormal use environments, smoke comes out or even ignited. Even if it is convenient for use or highly utilized, high risk of fire will require setting up fire prevention measures or regulation of use. Through in-depth fire investigation and research, we should promote the risk of fire and make efforts to prevent fire to minimize human life and property damage.

분당 신도시 9월 입주에 대비한 관계부처 종합점검 회의자료(건설부장관 주재, 관계부처 차관회의)

  • 한국주택협회
    • 주택과사람들
    • /
    • s.11
    • /
    • pp.88-92
    • /
    • 1991
  • 1. 이 자료는 최초입주하게 되는 2,500여세대 주민들에게 불편이 없도록 공공시설과 생활편익 시설을 차질없이 설치하고자, 분당현지에서 건설부장관이 주재하에 3월 8일 오후 2시 관계기관 차관회의를 개최한 내용임. - 회의일시: 1991.3.8 $14:00{\~}16:00$. - 회의장소: 분당신도시내 토지개발공사 건설현장사무소 . - 참석: 12개기관 국무총리 행정조정실장 경제기획원차관 내무부차관 교육부차관 동력자원부차관 체신부차관 환경처차관 철도청장 경기도지사 서울특별시 부시장 경기도교육위 교육감 한국토지개발공사 사장. 2. 이번 회의에서는 다음 사항들을 중점 논의할 계획이다. - 분당신도시 건설사업의 종합적인 추진대책의 협의. - 최초 입주자에게 불편이 없도록 편익시설$\cdot$기반시설의 적기 설치. $\cdot$ 학교, 동사무소, 우체국, 파출소 등 필수 공공시설. $\cdot$ 도로, 상하수도, 난방 등 도시기반시설. $\cdot$ 병원, 상가 등 생활편익시설.

  • PDF

The Demand Expectation of Heating & Cooling Energy in Buildings According to Climate Warming (기후 온난화의 영향에 의한 건물의 냉.난방에너지 수요량 예측)

  • Kim, Ji-Hye;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.119-125
    • /
    • 2006
  • The impacts of climate changes on building energy demand were investigated by means of the degree-days method. Future trends for the 21st century was assessed based on climate change scenarios with 7 global climate models(GCMs). We constructed hourly weather data from monthly temperatures by Trnsys 16. A procedure to estimate heating degree-days (HDD) and cooling degree-days (CDD) from monthly temperature data was developed and applied to three scenarios for Inchon. In the period 1995-2080, HDD would fall by up to 70%. A significant increase in cooling energy demand was found to occur between 1995-2004(70% based on CDD). During 1995-2080, CDD would Increase by up to 120%. Our analysis shows widely varying shifts in future energy demand depending on season. Heating costs in winter will significantly decrease whereas more expensive electrical cooling energy will be needed.

Social Economic Value of Community Energy Service (지역 에너지 사업의 사회적 경제성 분석)

  • Shin, Dong-Joon;Rhee, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.849-851
    • /
    • 2005
  • 전력산업 구조개편 이후 여러 가지 형태의 새로운 전력시장 참여자가 나타났다. 지역 에너지 사업(CES : Community Energy Service) 사업도 이러한 새로운 시장참여자의 하나로 소비자에게 전기뿐만 아니라 열과 냉, 난방 서비스를 동시에 제공하는 역할을 수행한다. 대부분 분산전원 기술을 이용하는 지역 에너지 사업은 기존 발전 사업자들이 경험하는 환경문제나 대규모 투자에 따른 위험을 피할 수 있는 새로운 전력사업 형태로 각광받고 있다. 또한 송전망의 부담을 주지 않고 소비지에 인접하여 전력을 공급할 수 있기 때문에 송전망 투자도 절감할 수 있는 장점을 보인다. 본 연구는 지역 에너지 사업의 편익을 알아보기 위하여 부하 모델링을 통하여 지역 에너지 사업의 운영 경제성을 평가하였다. 특히 연료인 천연가스 요금과 전기부하의 변화에 따른 경제성 변화를 평가하여 민감도를 분석하였다.

  • PDF

Design Temperature and Absolute Humidity for Peak Cooling and Heating Load Calculation with ETD Method (실효온도차법에 의한 최대열부하 계산용 온습도에 관한 연구)

  • Kim, D.C.;Seo, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.278-284
    • /
    • 1993
  • A simplified TAC method was developed for the selection of design temperature and absolute humidity for peak cooling and heating load calculation with ETD method. And the design data of the 11 major cities in Korea were obtained. Based on the simplified TAC method, the design data for summer and autumn cooling season were selected by the TAC 5.0% of July through August and TAC 5.0% of October, respectively. But the design data for winter heating season were selected by the conventional TAC 2.5% of the full winter season.

  • PDF

플로팅 건축물 창호의 개방감 평가를 위한 사례 연구

  • Kim, Ik-Hyeon;Do, Geun-Yeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.283-284
    • /
    • 2013
  • 플로팅 건축물은 일반 건축물과 달리 광활한 수상에 위치하며 따라서 개구부를 통해 보이는 조망에 의해 재실자의 거주 만족도를 크게 높일 수 있다. 그러나 바다라는 특수한 환경에 노출되어 있기 때문에 육상에 비해 외부 기후환경에 많은 영향을 받으며 특히 창호 등의 외장재는 비교적 높은 열관류율과 낮은 강도로 인해 무분별한 확장을 실행할 경우 실내 냉 난방에너지 소비가 증대와 태풍 및 월파 등으로 인한 인명 재산 피해를 초래할 수 있다. 본 논문에서는 플로팅 건축물에서 대부분의 재실자가 충분한 만족을 느낄 수 있는 창호 크기의 범위를 알아내기 위해서 일반 건축물의 조망 및 실내 개방감 평가에 관련된 국내외 연구의 사례를 조사하고 플로팅 건축물에서의 적용 방안에 대해 연구하였으며 그 결과 인체의 시야각을 이용해 내부 공간에서의 개방감을 측정하는 방법과 실물 축소모형을 이용해 개방감을 측정하는 방법을 제시하였다.

  • PDF

A Study of Spatial Information Platform for Intelligent Urban Facilities (도시시설물 관리 지능화를 위한 도시공간정보플랫폼 구성에 관한 연구)

  • Na, Joon-Yeop;Kim, Tae-Hoon
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2009.04a
    • /
    • pp.297-298
    • /
    • 2009
  • 지능화된 도시시설물 관리를 위해서는 상하수도, 가스, 난방 등 지하시설물 및 교량, 도로 등 지상시설물에 대한 관리시스템을 유기적으로 연계하고 상호운영성의 기반위에서 통합 운영환경을 제공할 수 있는 '지능형 도시공간정보 플랫폼'이 필요하다. 도시공간정보 플랫폼은 도시내 다양한 센서 단말 등으로부터 정보를 수집하고 이를 모니터링 및 분석하여 도시관리 및 정보제공 서비스를 수행하는 시스템이다. 본 연구에서는 도시공간정보 플랫폼에 대한 사용자 요구사항을 분석하고, 이에 따라 플랫폼을 구성하는 세부기능을 정의하였으며, 이를 종합하여 도시공간정보 플랫폼 모델을 제시하였다.

  • PDF

Application of Solar Energy to the House Heating System in Korea (한국의 주택 난방에 있어서의 태양열 이용)

  • 오세종;백제현
    • Journal of the KSME
    • /
    • v.18 no.3
    • /
    • pp.25-32
    • /
    • 1978
  • 1973년 석규파동 이후 세계 각국은 에너지 문제를 심각하게 다루어 왔다. 화석 연료의 유한성은 미래의 세계 에너지에 대한 연구에 박차를 가해왔다. 현재 사용되는 연료로는 화석연료인 석탄, 석유, 그리고 원자력등이 있다. 그러나 이들은 모두 그의 매장이 어느지역에 제한된 지역편재성이 있는 것이며 그의 사용에 따른 대기오염, 환경오염등의 점차적으로 큰 문제로 대두되고 있다. 본 연구에서는 과거 71년부터 77년까지의 기상조건을 중심으로 하여 기온, 수평면 일사량, 운량, 일조시간에 대한 전반적인 조사를 근거로 이에대한 통계를 제시하고, 이들의 상호관계에 대한 일 반적인 식을 유도하였다. 그리고 1977년 8월부터 78년 3월까지의 수령면 일사량과 서울 지방에서 최적치라고 알려진 53도 경사면에서의 전 일사량을 측정하여 이에 대한 자료를 제시함으로써 국 내에서의 태양열 이용에 대한 기초자료를 마련하였다. 이어서 주어진 집열기에 의한 태양열 주택 의 설계와 이에따른 경제성 타당 검토를 하고자 하였다.

  • PDF