• Title/Summary/Keyword: 난방 능력

Search Result 46, Processing Time 0.024 seconds

Experiment study on Heating Performance of Heat-pump chiller (실외온습도 변화에 따른 히트펌프 칠러의 난방성능에 관한 실험적 연구)

  • Lee, Kwon-Jae;Lee, Sang-Jae;Kim, Jung-Seok;Lee, Soo-Kwang;Park, Kyoung-Man
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1123-1126
    • /
    • 2010
  • 본 연구에서는 외기온습도에 따른 히트펌프 칠러의 난방성능을 조사하고자 하였다. 난방표준 온도조건에서 건구온도 및 습구온도 변화에 따른 히트펌프 칠러의 난방능력과 COP를 획득하기 위하여 항온항습 챔버와 항온수조를 사용하였다. 실험은 건구온도 $7^{\circ}C{\sim}17^{\circ}C$, 상대습도 67%~87%에서 수행하였다. 외기온도가 증가함에 따라 난방능력은 약 27%, COP는 약 28% 증가하였지만, 상대습도 증가에 따른 난방능력과 COP의 변화는 거의 없었다. 따라서 난방운전 시 건구온도의 영향은 크고, 상대습도의 영향은 미미함을 알 수 있었다.

  • PDF

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

Special Member - 고급 인력으로 ESCO 선두기업으로 떠오른 GS파워(주) ESCO사업팀

  • Choe, Won-Geun
    • The Magazine for Energy Service Companies
    • /
    • s.67
    • /
    • pp.52-55
    • /
    • 2010
  • 한국전력공사의 발전소와 한국지역난방공사의 지역난방 설비를 인수하면서 출범한 GS파워(주). 설립배경이 말해주듯 임직원 개개인의 높은 능력과 안정된 기반에서 출발한 만큼 GS파워는 지난 10년간 끊임없는 성장세를 나타내고 있다. 특히 2009년, ESCO사업에 첫 발을 내딛기 시작하며 세계적인 친환경에너지 기업으로 부상하고 있다.

  • PDF

Capacity and Power Input Performance Curves Creation of Water-cooled VRF Heat Pump for EnergyPlus (EnergyPlus 해석용 수랭식 VRF 히트펌프의 냉·난방 능력 및 소비전력 예측식 산출 기법)

  • Kim, Min-Ji;Kwon, Hyuk-Joo;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • Variable refrigerant flow (VRF) systems have recently attracted attention in many countries due to a variety of advantages over conventional system. Especially, the water-cooled VRF heat pump, including geothermal heat pump, is a system that accurately controls the flow rate of refrigerant for the improved efficiency under part load operation. This paper describe the process of generating the cooling and heating energy performance curve coefficients and performance expressions for modeling water cooled VRF system using EnergyPlus. Through this study, the process for generating performance curves can be implemented into EnergyPlus or other comparable building energy analysis tools for the long-term evaluation of heat pump under dynamic conditions.

ESCO 탐방-영평기계설비(주)

  • O, Hye-Eun
    • The Magazine for Energy Service Companies
    • /
    • s.45
    • /
    • pp.18-21
    • /
    • 2007
  • 영평기계설비(주)(대표 최영수)는 1992년부터 진행된 아파트지역난방 전환공사의 최초업자로 알려져있다. 지역난방 전환공사, 에너지절약 시설설치 공사 등 다양한 분야에서 설계, 시공 능력까지 고루갖춘 영평은 지난 12월, 에너지진단 전문기관으로 지정됐으며 건물이나 빌딩, 아파트의 에너지 진단을 실시, 최소한의 에너지로 최대한의 에너지절감 효과를 볼 수 있도록 돕고 있다. 수십 년간 에너지절약 사업 외길을 걸어온 영평기계설비(주) 최영수 대표를 만나 얘기를 들어봤다.

  • PDF

Field Application of a Latent Heat Storage Tank for Load Shaving of Domestic Hot Water Supply in District Heating (지역난방 급탕공급 부하균등화를 위한 잠열축열조의 현장 적용)

  • Park, Sung Yong;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.2
    • /
    • pp.42-47
    • /
    • 2021
  • In terms of district heating operation, efficient production and supply of heat by alleviating the peak load at a specific time require an application technology that can solve the inconvenience of the user and the difficulties of the supplier. In this study, a 78 ℃ class PCM heat storage tank suitable among the technologies that can solve these problems was manufactured and applied to the hot water supply facility for apartments in district heating users. As a result of the application of this system, it was confirmed that the supply temperature was constant to the user compared to the existing supply method. In addition, it was confirmed that the reduction of the peak load due to load equalization reduced the heat supply margin of 10% in the existing heat supply facility. And the construction cost of the new heat supply facility and the construction cost of heat users is decreased by 5% and 10%, respectively.

A Study on the Horizontal Ground Source Beat Pump Greenhouse Heating System with Thermal Storage Tank (축열조를 채용한 수평형 지열원 히트펌프 온실 난방 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.194-201
    • /
    • 2006
  • Greenhouses should be heated during nights and cold days in order to fit growth conditions in greenhouses. Ground source heat pump (GSHP) systems are recognized to be outstanding heating and cooling systems. A horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated the performance characteristics. The reasons for using thermal storage tank were discussed in detail. Thermal storage tank can provide heat for heating load that is larger than GSHP system heating capacity. The results of study showed that the heating coefficient of performance of the heat pump system was 2.69.

A Study on the Dehumidification effect of Adsorbent at low Temperature (저온에서 흡착제의 제습효과에 대한 연구)

  • Lee, Min-Seok;Jeong, Yun-Ho;Lim, So-Min;Heo, Jae-Woo;Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.177-182
    • /
    • 2020
  • Interest in heat pumps is increasing as an eco-friendly and energy-saving heating method. In particular, in order to develop a heat pump capable of heating in a low-temperature area, research to prevent frost on the surface of the outdoor unit is increasing. In other words, when heating through a heat pump in a low-temperature area, a frost layer is formed on the surface of the outdoor unit, which lowers the heat transfer performance, thereby reducing the heating capacity. Therefore, in this study, an adsorption-type dehumidification system is attached to remove the moisture vapor of the air into the outdoor unit of the heat pump. It is believed that this study can suggest the most effective dehumidification method in low temperature regions. In addition, it is expected that a heat pump with high energy efficiency can be developed by attaching an adsorption dehumidifying system to the front of the outdoor unit of the heat pump.

A Study on the Performance Characteristics of Water Heat Source Heat Pump System using CO2 Refrigerant (이산화탄소를 사용한 수열원 히트펌프 시스템의 성능 특성에 관한 실험적 연구)

  • Chang, Keun-Sun;Kang, Hee-Jeong;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3366-3373
    • /
    • 2011
  • In this study, performance characteristics of a water source heat pump system using $CO_2$ as a refrigerant are investigated experimentally. Cooling and heating capacities and COP of the system are analyzed for various system performance variables such as refrigerant charge, expansion valve opening, compressor frequency and internal heat exchanger. Results show that optimum amount of refrigerant charge and expansion valve opening exists at maximum point of COP curve, and cooling capacity increases but COP decreases with the increase of compressor frequency. When the internal heat exchanger is installed, cooling capacity increases about 4.0% whereas heating capacity decreases about 0.89% compared to the case without internal heat exchanger.