• Title/Summary/Keyword: 나선형구조

Search Result 156, Processing Time 0.028 seconds

A Development of Small-diameter Composite Helical Spring Structure for Reinforcement of Fiber Splice (광섬유 융착 부위 중접용 미소 직경 복합재료 스프링 구조물 개발)

  • 윤영기;정승환;이우일;이병호;윤희석
    • Composites Research
    • /
    • v.16 no.2
    • /
    • pp.26-32
    • /
    • 2003
  • Optical fibers, for splice, are stripped of their plastic coatings with a plastic stripper and cut off at the end. Therefore, stripped fibers often receive accidental damages and sustain small flaws or cracks. As a result, the breaking strength of a fiber splice made under normal conditions is reduced to about 0.4∼1 ㎏ on the average, nearly one-tenth of the fiber's strength. This makes it necessary to reinforce the splice. One of the most practical and reliable methods for optical fiber splicing is fusion splicing, comprising the steps of tripping the plastic coatings from the two fiber ends to be splice, placing the two bare fiber ends in an end-to-end position, and of fusion splicing, such as are fusion. Generally, steel bar (SB) sleeve is used to reinforce this fusion-splicing region. However, this type of sleeve has a critical defect to keep optical lose after bent by a sudden load. New type of composite spring (CS) sleeve is developed to make up for the weak points in the SB sleeve. This sleeve has an effect on restoration to the original state after eliminating the bending load. The optical spectrum analyzes results show the availability of reinforcement for the fusion splicing optical fiber using small diameter composite springs under the various loading conditions.

Behavior According to Confinement of Compressive Concrete on Flexural Members Reinforced with FRP Bars (FRP bar를 주근으로 사용한 콘크리트 휨부재의 압축측 콘크리트 구속에 따른 거동)

  • Seo, Dae-Won;Han, Byum-Seok;Shin, Sung-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.110-118
    • /
    • 2008
  • The use of FRP bar as reinforced concrete beams is considered as one of the most prominent solution that may overcome the corrosion of reinforcing steel bars. However, in the case of FRP reinforced concrete, both the reinforcing and the reinforced materials are brittle. For this reason, ductility of structures with FRP reinforcement is much less than that of structures with steel reinforcements. In this study, a method has been suggested to provide a meaningful quantification of ductility for concrete beams reinforced with FRP bars. This paper shows which the confinement to the compression concrete by the spiral can increase the ductility of FRP over-reinforced concrete beams.

A Study on the Characteristics of Oil-water Separation in Non-point Source Control Facility by Coalescence Mechanism of Spiral Buoyant Media (나선형 부유 고분자 여재의 Coalescence 특성을 이용한 비점오염원 저감시설의 유수분리특성 연구)

  • Kang, Sung-Won;Kim, Seog-Ku;Kim, Young-Im;Yun, Sang-Leen;Kim, Soo-Hae;Kim, Mee-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.950-955
    • /
    • 2007
  • Non-point source control system which had been designed only for oil-water separation in the fields of oil refinery and garage was upgraded in this research for the removal of runoff pollutants in impervious urban area. Pollutants including oil from driveway and bridge were eliminated by two types of pathway in the system. One is the coalescence mechanism that the oil droplets in the runoff come into contact with each other in the spiral buoyant media surface and form larger coalesced droplets of oil that are carried upstream to the oil layer. The other is the precipitation that solids in runoff were settled by gravity in the system. In this research, coalescing characteristics of oil and water separation were investigated through image analyses, and efficiencies of the non-point source control system were evaluated using dust in driveway and waste engine oil. Media made of high density and high molecular weight polyethylene was indeterminate helical shape and had sleek surface by analysing SEM photographs and BET. Surface area and specific gravity of media which were measured directly were 1,428 $mm^2$ and 45.3 $kg/m^3$ respectively. From the image analyses of the oil droplets photographs which were taken by using microscope, it was proved clearly that the coalescence was the main pathway in the removal of oil from the runoff. Finally, the performances of the non-point source control system filled up with the media were suspended solid $86.6\sim95.2%$, $COD_{Cr}$, $87.3\sim95.4%$, n-Hexane extractable materials $71.8\sim94.8%$ respectively.

Analysis of Superelevation Characteristics using RAMS Model (RAMS 모형을 이용한 편수위 특성 분석)

  • Kim, Sang Ho;Min, Sang Ki;Hwang, Sin Bum
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.209-209
    • /
    • 2011
  • 산지하천의 비율이 높은 국내 하천은 주로 만곡도가 높은 사행하천으로 이루어져 있으며, 만곡부가 교호적으로 나타나는 사행하천의 흐름구조는 매우 복잡하다. 산지하천의 특성상 홍수시에는 유속이 매우 빠르게 나타나며 하천의 수위가 상승하게 될 때 만곡부에서의 흐름 회전 방향이 나선형 흐름으로 바뀌어 하류방향으로 주 흐름에 중첩하여 발생하는 이차류로 인해 하도가 불안정해지고 내 외측의 수위차가 발생하는 편수위가 발생하면서 하도 바깥쪽으로 수위가 상승하는 현상이 나타나게 된다. 따라서 집중호우로 인해 하천에서 발생하는 재해는 주로 만곡부를 중심으로 발생하게 된다. 본 연구에서는 이와 같은 만곡부의 외측부에서 발생하는 수위상승으로 인해 제방의 월류 피해와 이차류로 인한 침식피해를 유발하게 되는 문제를 사전에 예측하기 위하여 $90^{\circ}$ 실험하도와 $180^{\circ}$ Sharp 실험하도에 2차원 유한요소 모형인 RAMS 모형을 적용하여 수리특성을 살펴보았으며, 모의 결과에 대한 정확도를 살펴보기 위해 실측자료와 비교 검토하였다. 이와 같은 연구결과는 만곡부에서 발생가능한 제방침식이나 월류로 인한 하천에서의 피해 방지에 크게 기여할 것으로 기대된다.

  • PDF

Influence of twisting angle between contacts on arc behavior in spiral type vacuum interrupter (나선형 구조의 VI 전극간의 비틀림 각도가 아크거동에 미치는 영향)

  • Kim, Byoung-Chul;Park, Jong-Bae;Park, Hong-Tae;Kang, Sung-Wha;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.373-375
    • /
    • 2008
  • In this paper the arc behavior in spiral type vacuum interrupter was analyzed by observing taken photographs from high-speed digital camera(10000frame/second) and current-voltage waveform from oscilloscope. As a result, the influence of twisting angle between contacts on arc behavior could be analyzed by matching and comparing arc voltage and photographs simultaneously.

  • PDF

A Study on Characteristics of Heat Transfer for a Rotating Heat Pipe with a Trigonal Cross Section (삼각 단면을 갖는 회전 열파이프의 열전달 특성에 관한 연구)

  • 이진성;김철주;김윤제;최영준;홍성은
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.114-121
    • /
    • 1997
  • 회전 열파이프의 열전달 성능은 액막 두께 및 증발부로 귀환되는 응축 액막 유동율에 의해 결정된다. 그 동안 응축액 유동율을 촉진시키기 위하여 용기 내벽에 groove, 테이퍼 및 나선형 코일을 삽입하여 유동율을 높이는 방법들이 연구되었다. 본 연구도 회전 열파이프의 내부 관벽 구조에 관한 것으로써 삼각 단면을 갖는 회전 열파이프의 열전달 특성을 파악하고자 하였다. 삼각 단면을 갖는 회전 열파이프는 고속 회전 영역에서 모서리 부분으로 액막이 집중되어 관 내벽에 형성되는 액막 두께를 줄일 수 있으나 증발부에서 국부적인 과열이 발생되어 불안정한 작동 상태를 나타내었다. 따라서 본 연구에서는 개선방안으로 증발부에 부분적으로 원형관을 접합하였으며, 그 결과 dry-out의 억제와 함께 삼각 유동 단면에 의한 액막 두께 감소 효과를 볼 수 있었다. 회전체 발열부 냉각에 적용시키기 위해서는 앞으로 최적의 기하학적 형상에 따른 충전율 및 액막에서의 열전달에 대한 정량적인 해석 연구가 필요할 것으로 생각된다.

  • PDF

Crosstalk Analysis of the Spiral Inductor in LTCC (다층 구조를 갖는 LTCC기술에서 나선형 인덕터로 인한 혼신 해석)

  • Kim, Seong-Nam;Kim, Gyung-Chul;Cho, Hyun-Min;Hwang, Chi-Jeon;Yang, Hyung-Kook;Lee, Hai-Young
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.260-264
    • /
    • 2003
  • It is possible to design the high performance, integration and low cost radio frequency components by using LTCC(Low Temperature Cofired Ceramic) technology. But there is a critical point to design the spiral inductor because of crosstalk effects. of the crosstalk effect of the spiral inductor are investigated using full-wave analysis of the FEM(Finite Element Method) in this paper. The results show that input power of the spiral inductor are coupled from 0.1% to 10% above 3GHz. Therefore, we should consider the crosstalk effects when we design the LTCC.

  • PDF

Analysis of 3D Arc Characteristics for Radial magnetic Field Type Electrode in Vacuum Interrupter by Using Arc voltage Equation (아크 전압 방정식을 이용한 횡자계진공차단부의 3차원 아크특성해석)

  • Kwak, Chang-Seob;Kim, Tae-Hun;Jung, Yeon-Ha;Lee, Se-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.786-787
    • /
    • 2015
  • 현재 진공인터럽터에서 사용되는 아크제어 방식은 크게 횡자계 방식과 축자계 방식이 있다. 본 연구에서는 횡자계 방식 중 나선형 타입 접점 구조에서의 아크 거동 패턴을 분석한다. 일반적인 아크 거동 해석을 위해서는 연속체적 접근을 통해 주요 캐리어에 대한 연속방정식, 운동방정식, 열방정식 등을 결합하여 아크의 거동 패턴을 분석해야 한다. 또한 매 시간 별로 아크의 움직임에 따른 격자 재설정 및 해석 등 시간적 소요가 심하다. 이러한 문제를 해결하면서 아크의 거동 패턴을 효율적으로 모사할 수 있는 기법을 강구하기 위해 여러 가정과 기존의 아크 모델들을 활용하여 독자적인 아크 거동 시뮬레이터를 개발한다.

  • PDF

Kinematics and Design of CNC Drill Grinding Machine (CNC 드릴 연삭기 구조 및 설계)

  • 강성균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.555-559
    • /
    • 1996
  • Based on the general drill grinding mechanism, termed the helical grinding system, the conceptual design of 5 axes CNC drill grinding machine is proposed. Unique determination of the grinding parameters for precise production of the desired flank geometry is discussed by utilizing a mathematical model. Also, different combinations of grinding parameters are mentioned in order to produce various drill geometries (conical, cylindrical, and planar drill) on the single proposed CNC machine. A manual helical grinding machine has been fabricated and consequently helical drills have been ground in order to check the feasibility of the proposed grinding mechanism and its functionality.

  • PDF

A Study on Measurement of Two-dimensional Velocity Distribution in River using ADCP (ADCP를 활용한 하천의 2차원 유속분포 측정 연구)

  • Yoo, Min-Wook;Kim, Young-Do;Lyu, Si-Wan;Seo, Il-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.916-920
    • /
    • 2007
  • ADCP(Acoustic Doppler Current Profiler)는 유수의 흐름을 방해하지 않으면서 물 속으로 일정 주파수의 초음파를 전송하고, 부유하는 입자들에 의해 산란되어 돌아오는 반향을 수집, 도플러효과를 이용하여 유속을 측정하는 장비이다. ADCP는 하천을 횡단하면서 순간적인 유속을 측정하므로 시간평균한 평균유속과의 차이가 발생하지만 1초에 1회 이상의 빠른 속도로 연직유속분포를 수집하면서 이를 공간적으로 평균함으로써 순간유속이 갖는 변동성을 완화시키는 특징을 갖는다. 본 연구에서는 ADCP를 활용하여 사행하천에서 수평방향 2차원 유속분포를 측정하고자 하였다. 만곡부가 교호적으로 나타나는 사행하천의 흐름구조는 매우 복잡하다. 특히 주 흐름의 수직인 단면에 나선형의 2차류가 관찰되는데, 이는 원심력과 횡방향의 수면경사 및 난류의 상호작용으로 발생된다. 주 흐름의 유속과 다른 분포를 나타낸다. 본 연구에서는 이찬주 등(2005)이 제시한 공간평균기법과 이동경로 수정을 통하여 측선별 2차원 유속분포를 측정하여 기 개발된 RAMS(서울대학교, 2007)를 적용하고 이를 검증하기 위한 자료를 확보하고자 하였다.

  • PDF