• Title/Summary/Keyword: 나선핀과 와이어

Search Result 4, Processing Time 0.019 seconds

Flow Induced Vibration and Suppression of Inclined Cylinder (유체유동에 의한 경사원주의 진동과 제진에 관한 연구)

  • 양보석;복정희일랑;암호탁삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1381-1390
    • /
    • 1992
  • This paper presents a dynamic characteristics of flow induced vibration of circular cylinder set with inclined angle against flow direction. The effect of the cylinder bounded by spiral fin and wire on the damping of flow induced vibration is investigated, i.e., inclined angle, spiral pitch angle and number of spiral thread are studied. As the results, the cylinder with spiral fin is most effective for the damping. Also the cylinder bounded by pitch angle 50.deg. and 2 spiral thread is most effective.

Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers (나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구)

  • Lee, Sang Hun;Yoon, Won Jae;Kim, Yongchan;Lee, Mooyeon;Yun, Seongjung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.205-212
    • /
    • 2013
  • The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

Analytical Study on the Heat Transfer Characteristics of a Spirally Coiled Circular Fin-Tube Evaporator Operated Under Non-Frosting Conditions (무착상 조건에서 나선형 원형핀-튜브 증발기의 열전달 성능에 관한 해석적 연구)

  • Lee, Moo-Yeon;Kang, Tae-Hyung;Kim, Yong-Chan;Park, Jae-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • The objective of this study is to predict the heat-transfer performance of a spirally coiled circular fin-tube evaporator in which either R134a or R600a was used; this heat-transfer performance was predicted by varying the mass flow rate, inlet air temperature, air flow rate, and tube thickness. Mean deviation for the analytical model from the measured data was ${\pm}8.3%$. Simulation results revealed that at a given mass flow rate, the heat-transfer rate of the evaporator using R600a was higher than that usingR134a because the enthalpy of the former is higher than that of the latter at the given conditions. The heat-transfer rate of both refrigerants increased with an increase in the air flow rate and inlet air temperature but decreased with an increase in the tube thickness.

회전 핀에 의한 이동 하중에 따른 보의 대변형 수치 해석

  • 정일섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.65-65
    • /
    • 2004
  • 스프링은 변위에 상응하는 에너지를 저장하는 기계 요소로서 다양한 분야에 적용되고 있으며, 나선형(helical) 스프링, 와선형(spiral) 스프링, 비틀림 막대, 디스크(disk) 스프링, 판(plate) 스프링, 일정 하중(constant force) 스프링 둥 다양한 종류가 있다. 근래 많이 사용되는 LCD 모니터 가운데 일부는 경사(tilt), 회전(pivot), 방향 전환(swivel) 등 모니터의 각도 변화가 가능하도록 제작되며, 이러한 각도 변화시 사용자가 적절한 반력을 느끼도록 인간 공학적으로 설계되어 있다.(중략)

  • PDF