• Title/Summary/Keyword: 나선각

Search Result 136, Processing Time 0.025 seconds

A Study of Inter-observer Agreements of Spiral Chest Computed Tomography in Diagnosing Pulmonary Embolism (폐색전증에서 나선형 컴퓨터 전산화 단층촬영의 관찰자간의 일치도에 관한 연구)

  • Kim, Yang-Ki;Lee, Young Mok;Kim, Ki-up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Hwang, Jung-Hwa;Kim, Dong Hun;Goo, Dong-Erk;Choi, Deuk-Lin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.473-479
    • /
    • 2005
  • Background : A pulmonary embolism often presents with nonspecific symptoms and signs. However, a delayed diagnosis can result in catastrophic outcome. The majority of preventable deaths associated with a pulmonary embolism can be ascribed to a missed diagnosis rather than to the failure of existing treatments. Therefore, accurate and rapid diagnostic methods are essential for the management of a pulmonary embolism. The recent generation of multidetector-row spiral CT scanners appears to outperform other imaging modalities in detecting a central and peripheral pulmonary embolism. However, there are some variations in the interpretations of the findings between observers. This study examined the inter-observer differences of the diagnoses in patients with a pulmonary embolism. Method : 64 patients who were diagnosed with a pulmonary embolism either clinically or with spiral chest CT from 2002 to 2004, were included. Two thoracic radiologists interpreted the multidetector-row spiral CT in terms of the diagnosis of a pulmonary embolism and the location of the thrombus independently. Among 64 patients, 14 patients were excluded because there was no evidence of a pulmonary embolism or there was different interpretation of the pulmonary embolism between radiologists. A clinical diagnosis was based on "Rules for predicting the probability of embolism". Results : The mean score of the patients according to the Wells method was $3.91{\pm}0.30$ (0-9). The accordance of the radiologists was 95% in the main, 85% in the lobar, 91.2% in the segmental, and 96% in the sub-segmental pulmonary arteries. After excluding the negative interpretation from both radiologists, their agreement was 76.2%(${\kappa}.$ 0.83) in the main, 57.6%(${\kappa}.$ 0.63) in the lobar, 51.5%(${\kappa}.$ 0.63) in the segmental, and 34.6%(${\kappa}.$ 0.49) in the sub-segmental pulmonary arteries. Conclusion : Chest CT has been recently applied to patients suspected of having a pulmonary embolism. It was found that spiral CT is a rapid test for diagnosing a thrombus, and there was reliable accordance between the observers from the area of the large pulmonary arteries. However, there was a lack of agreement between the observers in diagnosing thrombi located distal to the sub-segmental arteries.

Laminar Flow in the Entrance Region of Helical Tubes Connected with Straight Ones (직관과 연결된 나선관 입구영역의 층류 유동)

  • Kim, Young-In;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2008
  • A numerical study for three-dimensional laminar flow in the entrance region of helical tubes connected with straight ones is carried out to investigate the effects of Reynolds number, pitch and curvature ratio on the oscillation periods of the flow. The fully elliptic governing equations were solved by means of a finite volume method. The fully developed laminar flow boundary condition was applied at the straight tube inlet. This results cover a curvature ratio range of 1/10${\sim}$1/320, a pitch range of 0.0${\sim}$3.2, and a Reynolds number range of 62.5${\sim}$2000. A comparison is made with previous experimental correlations and numerical data. The developments of velocity, local and average friction factors are discussed. The average friction factors are oscillatory in the entrance region of helical pipes. It has been found that the angle required for the flow to be similarly developed is most affected by the curvature ratio. The pitch and Reynolds number do not have any significant effect on the angle. The characteristic angle ${\phi}_c(={\phi}/sqrt{\delta})$, or the characteristic length to diameter ratio $s_c(=l\sqrt{\delta} cos(atan{\lambda})/d)$, can be useful to represent the development of flow in helical tubes. As the pitch increases and as the curvature ratio and Reynolds number decrease, the amplitude and the number of flow oscillations along the main streamwise direction decrease.

Direction-Oriented Fast Full Search Algorithm at the Divided Search Range (세분화된 탐색 범위에서의 방향 지향적 전영역 고속 탐색 알고리즘)

  • Lim, Dong-Young;Park, Sang-Jun;Jeong, Je-Chang
    • Journal of Broadcast Engineering
    • /
    • v.12 no.3
    • /
    • pp.278-288
    • /
    • 2007
  • We propose the fast full search algorithm that reduces the computational load of the block matching algorithm which is used for a motion estimation in the video coding. Since the conventional spiral search method starts searching at the center of the search window and then moves search point to estimate the motion vector pixel by pixel, it is good for the slow motion picture. However we proposed the efficient motion estimation method which is good for the fast and slow motion picture. Firstly, when finding the initial threshold value, we use the expanded predictor that can approximately calculate minimum threshold value. The proposed algorithm estimates the motion in the new search order after partitioning the search window and adapt the directional search order in the re-divided search window. At the result, we can check that the proposed algorithm reduces the computational load 94% in average compared to the conventional spiral full search algorithm without any loss of image quality.

A Fast Full Search Motion Estimation Algorithm using Partitioned Search Window (세분화된 탐색 영역을 이용한 고속 전영역 움직임 예측 알고리즘)

  • Park, Sang-Jun;Jin, Soon-Jong;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1C
    • /
    • pp.9-15
    • /
    • 2007
  • We propose the fast full search algorithm that reduces the computation of the block matching algorithm which is used for motion estimation of the video coding. Since the conventional spiral search method starts searching at the center of the search window and then moves search point to estimate the motion vector pixel by pixel, it is good for the slow motion pictures. However the proposed method is good for the fast and slow motion because it estimates the motion in the new search order after partitioning the search window. Also, when finding the motion vector, this paper presents the method that reduces the complexity by computing the matching error in the order which is determined by local image complexity. The proposed algorithm reduces the computation up to 99% for block matching error compared with the conventional spiral full search algorithm without any loss of image quality.

Pattern Recognition Analysis of Two Spirals and Optimization of Cascade Correlation Algorithm using CosExp and Sigmoid Activation Functions (이중나선의 패턴 인식 분석과 CosExp와 시그모이드 활성화 함수를 사용한 캐스케이드 코릴레이션 알고리즘의 최적화)

  • Lee, Sang-Wha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1724-1733
    • /
    • 2014
  • This paper presents a pattern recognition analysis of two spirals problem and optimization of Cascade Correlation learning algorithm using in combination with a non-monotone function as CosExp(cosine-modulated symmetric exponential function) and a monotone function as sigmoid function. In addition, the algorithm's optimization is attempted. By using genetic algorithms the optimization of the algorithm will attempt. In the first experiment, by using CosExp activation function for candidate neurons of the learning algorithm is analyzed the recognized pattern in input space of the two spirals problem. In the second experiment, CosExp function for output neurons is used. In the third experiment, the sigmoid activation functions with various parameters for candidate neurons in 8 pools and CosExp function for output neurons are used. In the fourth experiment, the parameters are composed of 8 pools and displacement of the sigmoid function to determine the value of the three parameters is obtained using genetic algorithms. The parameter values applied to the sigmoid activation functions for candidate neurons are used. To evaluate the performance of these algorithms, each step of the training input pattern classification shows the shape of the two spirals. In the optimizing process, the number of hidden neurons was reduced from 28 to15, and finally the learning algorithm with 12 hidden neurons was optimized.

The Design of Resonator for Miniaturization of Magnetic Resonance Wireless Power Transfer System (자기공진형 무선전력전송 시스템의 소형화를 위한 공진기 설계)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.163-169
    • /
    • 2016
  • In this paper, we miniaturized the loop and coil in magnetic resonance wireless power transfer(MR-WPT) system for application to the small mobile device. The proposed disk type double coil resonator was designed to cause resonance at 6.87 MHz. It is composed of thin copper on both-side of acrylic substrate structured 2 mm width, 1 mm pitch and 8 turns. The outer radius of spiral coil pattern is 9 cm. And the proposed loop was made of the copper wire 5 mm diameter of cross-section. The size of loop is 10 cm diameter. For resonance at 6.87 MHz, the capacitor with 3,300 pF was connected in series on the loop. We rearranged the resonators and organized several WPT systems which is rearranged by resonators. The highest transfer efficiency of miniaturized WPT system was 35.67 %. This proposed design of spiral double coil will contribute to make resonator smaller for appling small and thin mobile device.

Changes in CT Number and Noise Level according to Pitch in Spiral Image Acquisition (나선형영상획득에서 Pitch에 따른 CT 감약계수와 잡음의 변화)

  • Kang, SungJin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.981-989
    • /
    • 2020
  • In this study, a self-made customized phantom was used to quantitatively measure the change in CT number and noise according to the change of pitch. In order to acquire an image using the phantom, the inside of the phantom was filled with sterile distilled water. Inside the glass tube, a solution obtained by diluting the ratio of normal saline and contrast medium to 100%(NS), 400:1, 200:1, 100:1, 50:1, respectively, was placed and imaged. At this time, the pitch was divided into steps of 0, 0.35, 0.7, 1.05, and 1.4 for each dilution ratio of the solution and imaged, respectively. One-way ANOVA analysis were performed to verify whether the mean of the CT number and noise values measured in all ROIs by dilution ratio showed a significant difference according to the change in pitch. As a result of the experiment, there was no statistically significant difference in the change of the CT number according to the change in the pitch for each dilution ratio, but the noise value tended to increase with the increase of the pitch, and showed a statistically significant difference. In the spiral image acquisition of CT, noise can be changed to a significant level depending on the pitch. Therefore, it will be necessary to set the quality evaluation items and criteria for CT images using the spiral image acquisition method.

A Treatability Study on the Soil Washing Device for the Remediation of Oil-Contaminated Soil (유류 오염토양 복원을 위한 토양세척 장비의 적용성 연구)

  • Kong, Jun;Choi, Sang-Il
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.109-116
    • /
    • 1998
  • Treatability tests of a soil washing device were performed for the remediation of eil-contaminated soil. The contaminant-containing soil with water was first fed into a oc-current screw conveyor and then into a counter-current washer. Surfactant was introduced into the washer and feeding soil was continuously separated on the basis of #40 mesh at the same time. A washing efficiency of 97.9% was achieved by the the soil washing device optimized.

  • PDF

Performance Characteristics of a Cross-Flow Fan with Various Impeller Outlet Angles and Rearguiders (임펠러 출구각 및 리어가이더 형상 변화에 따른 횡류홴의 성능 특성)

  • Kim, H.S.;Kim, D.W.;Yoon, T.S.;Park, S.K.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.851-856
    • /
    • 2003
  • A cross-flow fan consists of an impeller, a stabilizer and a rearguider. When it applied for an air conditioner, an evaporator should be added. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there are a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, the reciprocal relation between the impeller and the flow passage is the important factor for performance improvement of the cross-flow tan because each parameter is independent. The performance characteristics in the cross-flow fan are graphically depicted with various impeller outlet angles and rearguiders.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF