• Title/Summary/Keyword: 나사못 고정술

Search Result 65, Processing Time 0.023 seconds

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

Arthrodesis of the First metatarsophalangeal joint for Rheumatoid arthritis, using a lag screw and dorsal plate (류마토이드 관절염 환자의 족무지 외반증에 대한 제 1 중족 족지 관절 고정술 -지연 나사못과 배부 금속판을 이용한 치험-)

  • Sung, Il-Hoon;Lee, Hyung-Sang;Whang, Kuhn-Sung;Park, Kee-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.142-148
    • /
    • 2001
  • Purpose: To investigate the short term result of the first metatarsophalangeal arthrodesis for treating the hallux valgus deformity of rheumatoid arthritis, using a lag screw and dorsal mini-plate. Materials and Methods: From December 1999 to September 2001, The first metatarsophalangeal arthrodesis of 14 cases (9 patients) was underwent, using a lag screw and dorsal mini-plate. The follow-up period was averaged in 14.6 months. The subjective findings with respect to pain, functional aspect of ability to stand and walk, and to shoe-wearing were evaluated. The objective findings, such as the gross alignment and the radiological measurements for the hallux valgus angle, 1,2 intermetatarsal angle, and dorsiflexion angle were also studied. Results: After the arthrodesis of the first metatarsophalangeal joint, the subjective improvement in pain, function and alignment was graded as excellent in seven (50%) feet, good in seven (50%) feet, and fair or poor in none. The hallux valgus angle and 1,2 intermetatarsal angle were reduced from $44.1{\pm}7.1$ and $15.5{\pm}6.2$ degrees to $13.6{\pm}2.6$ and $10.2{\pm}2.2$ degrees respectively. The dorsiflexion angle was measured in $20.3{\pm}3.7$ degrees after the fusion. The radiological fusion was observed at average 8 weeks after the operation in all cases. The overall complication of the procedure was few, except the delayed wound healing in one. Conclusion: The arthrodesis of the first metatarsophalangeal joint using a lag screw and dorsal mini-plate was regarded as an excellent method of various operative modalities to correct the rheumatoid hallux valgus deformity.

  • PDF

The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods (축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증)

  • Choi, Jun-Woong;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Hyeon-Seon;Kim, Eun-Young;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

Anterior Screw Fixation of Type II Odontoid Fracture (제 II 형 치상돌기 골절에서 전방경유 나사못 고정술)

  • Kim, Myung-Jin;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Hwang, Sung-Kyu;Hamm, In-Suk;Park, Yeun-Mook;Kim, Seung-Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1461-1468
    • /
    • 2000
  • Objective : The aim of this study is to evaluate clinical outcome of anterior screw fixation for type II odontoid fractures for the prliematim of atlanatoaxial mobility. Methods : Between 1995 and 1999, we treated 15 cases of type II odontoid fractures by anterior screw fixation among 44 cases of odontoid fractures. Thece included 14 males and 1 female aged from 23 to 63 years, with a mean age of 39.7 years. The causes of trauma were traffic accident in 13 cases, slip down in 1 and fall down in 1. The fracture type was type II-P in 7 cases, type II-A in 3, type II-N in 2 and type II-A and P in 3. The fracture line was oblique downward and backward in 6 cases, oblique downward and forward in 3 and horizontally in 6. The range of follow up was 4 to 47 months(mean 26.5 months). Results : Adequate reduction and fixation were obtained in 12 cases. Three cases in which fracture type and line were type II-A and oblique downward forward were failed, so posterior transarticular screw fixation was performed. All except 3 failed cases had adequate cervical movement and stability. There were no operative mortality nor morbidity. Conclusion : Anterior screw fixation provides the best anatomical and functional results for type II odontoid fracture with intact transverse ligament when fracture line is horizontal or oblique downward and backward. But it is limited when fracture line is oblique downward and forward.

  • PDF

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.

Anterior Cervical interbody Fusion with Cervical Spine Locking Plate (경추 물림 금속판을 이용한 경추 전방추체간 유합술)

  • Park, Joo-Tae;Ahn, Gil-Young;Lee, Young-Tae;Ahn, Myun-Whan
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.209-219
    • /
    • 1997
  • Objectives: Anterior approach to achieve arthrodesis of the cervical spine has become a widely accepted and often-used approach since its earliest reports by Bailey and Badgley, Smith and Robinson and Cloward. However, anterior interbody fusion in the presence of the posterior instability may be complicated by the bone graft dislodgement, kyphotic defomity or nonunion. As an attemp to prevent this undesirable complication, additional methods such as skeletal traction, halo appratus or even posterior fusion has been utilized. Therefore, The cervical spine locking plate(CSLP) with the anterior intervertebral body bone grafting provide immediate cervical stabilization and widely successful in achieving fusion. Material and methods: This study analysed 14 patients who underwent a single anterior procedure and application of CSLP for the treatment of the cervical spinal disorder. Eleven patients were disc herniations and three patients were traumatic lesion. The average age of the patient was 47 years and the mean follow up periods was 20 months ranging from 13 to 27 months. Results: Ambulation was started 2nd day after the operation with the aid of the Philadelpia orthoses. Bone union was observed 13 cases on average 12 weeks after operation. The one case was nonunion with plate breakage without clinical symptom. Conclusion: Anterior fusion with CSLP are thought to be a safe and valuable method for treating cervical spine disorder.

  • PDF

Comparative Biomechanical Study of Stiffness on Ligamentous Attached Sites of Distal Femur - Experimental Laboratory Study on Cadaver Femora - (원위 대퇴골 인대 부착부의 강도 비교 - 사체의 대퇴골에 행한 실험적 연구 -)

  • Kwak, Ji-Hoon;Sim, Jae-Ang;Yang, Sang-Hoon;Kim, Dong-Hee;Lee, Beom-Koo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.26-32
    • /
    • 2009
  • Purpose: This study was performed to compare the strength of ligamentous attached sites of cadaveric distal femur and to obtain reliable biomechanical data to use in ligamentous reconstruction or augmentation. Materials and Methods: Fifteen cadaveric distal femurs were used for this study. After measuring the bone density, 5.0 mm cannulated screw (Experiment 1) or reconstructed porcine ligament (Experiment 2) was inserted into the each ligamentous attached sites of anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL) and lateral collateral ligament (LCL). In experiment 2, reconstructed porcine graft was fixed with bioabsorbable screw in ligamentous insertion sites. And we measured the maximal pullout force of each ligamentous attached sites of cadaveric distal femur. Results: Average bone mineral density was $1.205{\pm}0.137\;g/cm^2$ in experiment 1, $1.236{\pm}0.089\;g/cm^2$ in experiment 2, which showed no statistically significant differences. In experiment 1, average pull-out strength of ACL, PCL, MCL and LCL group were $519.1{\pm}111.7$ N, $638.9{\pm}144.4$ N, $169.7{\pm}56.0$ N, $225.6{\pm}61.5$ N respectively. In experiment 2, the average pull-out strength were $310.6{\pm}31.0$ N, $379.9{\pm}47.4$ N, $104.0{\pm}14.4$ N, $131.5{\pm}21.9$ N respectively. In experiment 1, there was no significant difference between ACL and PCL group and between MCL and LCL group. However, the maximal pullout strength of MCL and LCL group were significantly lower than that of ACL and PCL group (p<0.01). Experiment 2 showed the same results of experiment 1. Conclusion: Because stiffness of MCL and LCL attached sites are much lower than that of ACL and PCL attached sites, we may consider augmented fixation in ligamentous reconstructions of MCL and LCL.

  • PDF

Allogeneic Inlay Cortical Strut Grafts for Large Cysts or Post-curettage Cavitary Bony Defects (거대 낭종성 골병소 또는 소파 후 잔유 골 결손부에 시행한 내재형 동종 피질 지주골 이식술)

  • Chung, Yang-Guk;Kang, Yong-Koo;Kim, Chol-Jin;Lee, An-Hi;Park, Jeong-Mi;Bahk, Won-Jong;Yoo, Hyun-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • Purpose: This study was aimed to evaluate the result of inlay cortical strut bone grafts for large cysts or cavitary bone lesions in long bones. Materials and Methods: Seven patients with large cyst or cavitary bony lesions were managed with curettage, allogeneic inlay cortical strut and cancellous bone grafts. Additional plate and screw fixations were performed in 6 patients. There were three SBCs, two FDs with secondary ABC changes, one FD and one post-cement spacer removal state. Three of them had pathologic fractures. Progression of bone healing and mechanical support and functional result were evaluated. The mean follow-up period was 25.4 months. Results: Incorporations into host bones were progressed in all, average 4.2 months in six metaphyseal regions and 5.8 months in five diaphyseal regions respectively. Full structural supports were achieved in all except one patient without any additional procedures. No allograft-related complication was developed. Mean functional score according to the MSTS criteria was 29.6 at last follow up. Conclusion: Inlay cortical strut graft provided additional mechanical stability and bone stock for screw purchase in large cyst or cavitary defects of long bones, which allow early mobilization and excellent functional outcome.

Clinical Comparison of Two Types of Hook Plate in Surgical Treatment of Acromioclavicular Dislocation - AO Hook Plate and Wolter Plate - (견봉 쇄골 관절 탈구의 수술적 치료에서 두 가지 갈고리 금속판의 임상적 비교 - AO Hook Plate와 Wolter Plate -)

  • Choi, Jea-Yeol;Kim, Eugene;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Se-Jin;Lee, Seung-Hee;Lee, Jae-Wook;Choi, Kyu-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • Objective: To evaluate if acromial locking in hook plate is necessary for surgical treatment of acromioclavicular dislocation by compare Wolter plate and AO hook plate. Methods: Seventy one patients who have Rockwood type III to V acromioclavicular joint dislocation treated with AO hook plate and Wolter plate were involved. Among them, 39 patients were treated with Wolter hook plate and 32 patients with AO hook plate. The Constant-Murley score and the range of motion of shoulder joint were measured on postoperative 1st ,$3^{rd}$, $6^{th}$ and $12^{th}$ months, and the radiological complications involving plate and bone were investigated. Results: Constant-Murley score of postoperative one year were $83.2{\pm}6.8$ in AO hook plate group and $85.2{\pm}5.3$ in Wolter plate group without statistical difference (p<0.05). Faster recover of forward elevation and external rotation were examined in Wolter plate group at first and third months after surgery than those of AO hook plate group, but there were no significant difference between after six months or later after surgery. Four cases of loosen or broken screws and one case of pull-out of plate were found in Wolter plate group. Seven cases of subacromial bony erosion and one periprosthetic fracture were found in AO hook plate group. Conclusion: Although clinical outcomes of both two methods were same, no matter if acromial locking system was or not. More radiological complication of plate and bone were found in AO hook plate than that of Wolter plate. However also had disadvantage like larger incision during surgery.