Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Analysis on the Correlation between Hydrological Data and Raw Water Turbidity of Han River Basin (한강수계의 수문자료와 원수탁도의 상관관계 분석)

  • Jeong, Anchul;Kang, Taeun;Kim, Seongwon;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • A correlation analysis between raw water turbidity at two wide-area water treatment plants and hydrological data was conducted for efficient water supply, design and management of water treatment plant. Both correlation analysis and principal component analysis were conducted using hydrological time series data such as inflow discharge, outflow discharge, and rainfall at dam basin of intake station of wide-area water treatment plants. And, forecasting of change in turbidity was conducted using regression equation for turbidity prediction. The raw water turbidity of two water treatment plants was strongly related to time series of discharge. The raw water turbidity of Chungju water treatment plant is strongly related to outflow discharge at Chungju dam (0.708). Whereas, the raw water turbidity of Wabu water treatment plant is strongly related to inflow discharge at Paldang dam (0.805). Similar trends between turbidity forecasting result using regression equation and calculation result using estimation equation on Korea water supply facilities standard were obtained. The result of this study can provide basic data for construction and management of water treatment plant.

Recycling of Waterworks Sludge in Red Clay Bricks Manufacturing (정수슬러지를 이용한 점토벽돌 생산 기술 개발 연구)

  • Hwang, Hyeon-Uk;Kim, Ji-Hoon;Kim, Young-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.217-222
    • /
    • 2009
  • This study was conducted to search possibilities of the use of sludge from waterworks industry in the manufacturing of red clay bricks. Different compositions of the sludge were added into the raw materials of the bricks and required engineering characteristics of the manufactured bricks were examined. Compressive strength, plasticity, and surface absorption of the recycled bricks were analyzed and were compared with the bricks quality standard rules and regulation for quality assurance of the product. Compressive strength of the bricks made in a ratio 75% clay, 5% sludge and 20% silica was found 261.3 $kg_f/cm^3$ and that was comparable with first grade bricks standard. Compressive strength of the bricks made in a ratio 70% clay, 10% sludge, and 20% silica was found 249.9 $kg_f/cm^3$ while it was decreased to 217.3 $kg_f/cm^3$ when bricks were made in a ratio 65% clay, 15% sludge and 20% silica. However, these values of compressive strength were in agreement with the bricks quality standard. Surface absorption of the bricks made by the mixing of 20% silica with varying amount of sludge, i.e., 5%, 10%, and 20% was found 10%, 9.65% and 10.92% respectively. These values satisfied the quality standard of bricks of grade 1 and 2. Recycling of proper amount of sludge in bricks making could produce bricks of high engineering characteristics.

Variation of Inundation Area Considering of Inverts at Surcharged Manhole (과부하 맨홀에서의 인버트 설치를 고려한 침수면적 변화)

  • Kim, Chae Rin;Kim, Jung Soo;Rim, Chang Soo;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.220-220
    • /
    • 2017
  • 일반적으로 XP-SWMM 모형을 이용한 침수모의를 실시할 경우 과부하 맨홀에 손실계수의 적용 시와 미적용 시에 침수 범위의 차이가 상이함에도 불구하고 보다 실제적인 침수면적의 모의를 위하여 에너지 손실 적용에 대한 도시침수해석의 구체적인 연구가 미흡한 실정이다. 또한 과부하관거에서의 배수능력을 증대하기 위하여 설치되는 맨홀 내 인버트의 침수저감 효과에 대한 분석이 필요한 실정이다. 이원 등(2015)은 군자배수구역을 대상으로 손실계수의 적용 방안 및 손실계수 적용에 따른 침수면적의 변화를 분석하였으나, 맨홀의 형상 및 인버트의 설치유무에 대한 사항을 고려하지 않았다. 그러므로 기 산정된 과부하 맨홀에서의 손실계수를 적용 및 인버트 설치에 따른 침수범위 변화의 분석이 필요할 것으로 판단된다. 본 연구에서는 손실계수 및 인버트 설치 여부에 따른 침수범위의 변화를 분석하기 위하여 도림천의 도림1배수분구를 대상으로 XP-SWMM을 활용하여 침수해석을 실시하였다. 김정수(2010)가 수리모형실험을 통하여 인버트를 설치하지 않은 기본형 맨홀에서 산정된 손실계수 0.61과 반원형, U자형 인버트를 각각 설치했을 시에 0.37, 0.30으로 산정된 손실계수를 XP-SWMM모형의 각 과부하 맨홀에 적용하였다. 침수모의 결과 과부하 맨홀에 손실계수를 적용하지 않은 경우의 침수면적은 21.14 ha로 모의되어 실제 침수면적과 약 60 % 정도의 일치율을 보였으나, 인버트를 설치하지 않은 기본형 맨홀의 손실계수를 적용한 경우의 침수면적은 37.12 ha로 모의되어 실제 침수면적인 35.65 ha와 거의 유사하게 나타났다. 또한 반원형 인버트를 고려한 경우의 침수면적은 28.04 ha, U자형 인버트 설치를 고려한 경우의 침수면적은 25.90 ha로 모의되었다. 인버트를 미적용한 경우의 침수면적과 비교하면 침수면적이 각각 24 %, 30 % 감소하였다. 따라서 도시 침수피해를 저감하기 위해 과부하 맨홀에 인버트를 설치한다면 맨홀내의 에너지 손실이 저감되고 배수능력이 향상되어 침수피해 면적과 침수심을 감소시킬 수 있을 것으로 판단된다.

  • PDF

Study on water quality prediction in water treatment plants using AI techniques (AI 기법을 활용한 정수장 수질예측에 관한 연구)

  • Lee, Seungmin;Kang, Yujin;Song, Jinwoo;Kim, Juhwan;Kim, Hung Soo;Kim, Soojun
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.3
    • /
    • pp.151-164
    • /
    • 2024
  • In water treatment plants supplying potable water, the management of chlorine concentration in water treatment processes involving pre-chlorination or intermediate chlorination requires process control. To address this, research has been conducted on water quality prediction techniques utilizing AI technology. This study developed an AI-based predictive model for automating the process control of chlorine disinfection, targeting the prediction of residual chlorine concentration downstream of sedimentation basins in water treatment processes. The AI-based model, which learns from past water quality observation data to predict future water quality, offers a simpler and more efficient approach compared to complex physicochemical and biological water quality models. The model was tested by predicting the residual chlorine concentration downstream of the sedimentation basins at Plant, using multiple regression models and AI-based models like Random Forest and LSTM, and the results were compared. For optimal prediction of residual chlorine concentration, the input-output structure of the AI model included the residual chlorine concentration upstream of the sedimentation basin, turbidity, pH, water temperature, electrical conductivity, inflow of raw water, alkalinity, NH3, etc. as independent variables, and the desired residual chlorine concentration of the effluent from the sedimentation basin as the dependent variable. The independent variables were selected from observable data at the water treatment plant, which are influential on the residual chlorine concentration downstream of the sedimentation basin. The analysis showed that, for Plant, the model based on Random Forest had the lowest error compared to multiple regression models, neural network models, model trees, and other Random Forest models. The optimal predicted residual chlorine concentration downstream of the sedimentation basin presented in this study is expected to enable real-time control of chlorine dosing in previous treatment stages, thereby enhancing water treatment efficiency and reducing chemical costs.

Enhancement of Coagulation and Flocculation Efficiencies by Ultrasonic Chemical Spray Nozzle I (초음파 약품분사노즐을 이용한 응집효율 향상 I)

  • Kim, Jin-Kook;Cho, Soon-Haing;Ha, Dong-Yun;Koh, Jae-Seok;Kim, Yong-Hyun;Choi, Seung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • To establish low-cost and high efficiency water treatment process, feasibility of applying ultrasonic spray nozzle for chemical injection was evaluated. Ultrasonic spray nozzle was manufactured using piezoelectric ceramics. Treatment efficiencies of contaminants by ultrasonic spray nozzle were compared with conventional chemical mixing such as back-mixing. It was found out that the rate of chemical diffusion rate by ultrasonic spray nozzle was faster than by back-mixing method. Removal efficiencies of various contaminants, such as turbidity, organics and microorganism by ultrasonic spray nozzle were also higher than by back-mixing method. By adapting ultrasonic spray nozzle in coagulant injection process, it can be prevented that the decline of treatment efficiency by coagulant overdose. The amount of coagulant can be reduced by applying ultrasonic spray nozzle in water treatment. Along with these advantages chemical mixing chamber is not required if ultrasonic spray nozzle is adapted. From these results, it can be concluded that chemical injection by ultrasonic spray nozzle is an economical and highly efficient device for coagulant mixing.

Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes (수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화)

  • Lee, Jae-In;Kim, Do-Hwan;Lee, Ji-Hyung;Kim, Dong-Youn;Hong, Soon-Heon;Shin, Pan-Sae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.362-368
    • /
    • 2005
  • The pH, alkalinity and calcium hardness could be adjusted by $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ addition in the water treatment process for corrosion protection of the water pipes. This research was performed to investigate the effect on the variation of water quality on the unit process by addition $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ in water treatment process. Carbon dioxide and lime were added before the coagulation basin and soda ash was added after the BAC process. pH and aklainity were increased at coagulation basin then after the water qualities had sustained similiarly to BAC process. There was no effect on turbidity and DOC removal efficiency during experimental period by addition\ $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ solution was added into clear well, the last process for optimum control of CCPP and is used mainly to control pH and alkalinity. In this research, average pH, alkalinity, and calcium hardness in treated water were 8.39, 61.4 mg/L as $CaCO_3$, 59.4 mg/L as $CaCO_3$, respectively and CCPP of treated water was higher than 29.5 mg/L to BAC process water, so adjusted water was expected to prevent internal corrosion of water pipe.

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.

Effect of Application of Water Treatment Sludge on the Yields and Chemical Properties of Soybean(Glycine max) and Carrot(Daucus carota) (정수장슬러지 시용이 대두 및 당근의 수량과 화학적 특성에 미치는 영향)

  • Chang, Ki-Woon;Lee, In-Bog;Lim, Jae-Shin;Kim, Young-Han;Lee, Sang-Suk;Lim, Hyun-Taek
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.3
    • /
    • pp.275-281
    • /
    • 1996
  • The objective of the study was to investigate the effects of water treatment sludge (WTS) on the growth of soybean and carrot, and uptake of some inorganic components in the plants. WTS was incorporated to field at the rates of 0, 1, 3, and 5 tons per 10a on the basis of dry weight. With the application of the sludge, OM and CEC in the soil increased slightly while the concentration of available phosphorous decreased. And heavy metals, including Pb, Cd, Cr, As and Hg, were not detected at the harvest stage in crops. With an increase in the application of the sludge, the concentration of phosphorous in the seed of soybean and the root of carrot tended to be decreased. There seems no correlation between rate of application of the sludge and uptake of Al in the plants. The yield of soybean was the highest when applied to one ton sludge and the yield on carrot increased with an increase in rate of applied sludge. Also, the concentration of carotene increased with an increased application of the sludge. But, application of WTS showed to deteriorate the visual quality with an irregularity of carrot's surface. This results indicate that application of WTS will be give a positive and negative effects on soil and crops.

  • PDF

A Study on Applicability of Coagulant Mixer and Flow Analysis of the Non-powered Vortex Mixer using CFD (전산유체역학(CFD)을 이용한 무동력 와류 혼화장치의 유동해석 및 응집제 혼화장치 적용 가능성 연구)

  • Kim, Soo Yeon;Chae, Jong Seong;Kim, Sin Young;Zhang, Meng Yu;Ohm, Tea In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.706-713
    • /
    • 2017
  • This study compared and analyzed the water treatment efficiency and the applicability of water treatment plant using the existing Mechanical Rapid-Mixer by introducing the Non-powered Vortex Mixer to the domestic water treatment plant. For this study, fluid flow characteristics and head loss of a Non-powered Vortex Mixer are calculated by Computational Fluid Dynamics (CFD)respectively. The head loss rate inside the mixer was 11.30% when the inflow velocity was 0.5 m/sec, 16.27% at 0.6 m/sec and 21.44% at 0.7 m/sec, the head loss rapidly increased at the optimal velocity of 0.5 m/sec. For the inflow velocity of 0.5 m/sec, the turbulent intensity at the inlet was 2.37% and at the outlet was 7.83%, so there was sufficient mixing strength for the particulate matter and the coagulant. The result of the water quality of the treatment plants with the inflow velocity of 0.38 m/sec that was operated in three years after replacing all 12 units of the existing Rapid-Mixer with the Non-powered Mixer met the standards. Hence, it is possible to reduce the energy consumption of 64,143 ~ 65,306 kWh/year since the Rapid-Mixer is replaced by the Non-powered Vortex Mixer.