• Title/Summary/Keyword: 김유근

Search Result 321, Processing Time 0.018 seconds

Random Walk Simulation of Atmospheric Dispersion on Surface Urbanization over Complex Terrain (복잡지형에서 도시화에 따른 대기오염 확산에 관한 시뮬레이션)

  • 이순환;이화운;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.67-83
    • /
    • 2002
  • The coupled model (SMART) of dynamic meteorology model and particle dispersion model was developed. The numerical experiment on the relationship between change of land use and diffusion behavior in complex terrain was carried out using this model. It tried to investigate the change of particle diffusion behavior and local weather under the condition in which land-land breeze and sea breeze and mountain breeze intermingled. The numerical experiment results are as follows; 1) The more complicated local circulation field of the interaction of sea breeze, mountain breeze and Land -land breeze is formed. Then, the region circulation in which the urbanization is specific by location of the region is strengthened and is weakened. 2) Though in the region with dominant sea breeze, Land-land breeze does not appear directly, the progress of the sea wind to the inland is affected. 3) In the prediction of the air diffusion, emission high quality and accurate information of the emission site are important. That is to say, the dispersion predicting result which emission high quality and small error of the site perfectly vary for Land - land breeze in the effect may be brought about.

Meteorologically Adjusted Ozone Trends in the Seoul and Susan Metropolitan Areas (서울과 부산지역 기상의 영향을 제거한 오존농도 추세)

  • 김유근;오인보;황미경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.561-568
    • /
    • 2003
  • Surface ozone concentrations are highly sensitive to meteorological variability. Therefore, in order to reveal the long-term changes in ozone due to the changes in precursor emissions, we need to remove the effects of meteorological fluctuations on the annual distribution of surface ozone. In this paper, the meteorologically adjusted trends of daily maximum surface ozone concentrations in two major Korean cities (Seoul and Busan) are investigated based on ozone data from 11 (Seoul) and 6 (Busan) sites over the period 1992 ∼ 2000. The original time series consisting of the logarithm of daily maximum ozone concentrations are splitted into long-term, seasonal and short-term component using Kolmogorov-Zurbenko (KZ) filter. Meteorological effects are removed from filtered ozone series using multiple linear regression based on meteorologcial variables. The long-term evolution of ozone forming capability due to changes in precursor emission can be obtained applying the KZ filter to the residuals of the regression. The results indicated that meteorologically adjusted long-term daily maximum ozone concentrations had a significant upward trend (Seoul: + 3.02% yr$^{-1}$ , Busan: + 3.45% yr$^{-1}$ ). These changes of meteorologically adjusted ozone concentrations represent the effects of changing background ozone concentrations as well as the more localized changes in emissions.

A Study on Visibility Impairment Impact of the Plume from a Vast Point Source (거대 점 오염원의 플룸에 의한 시정 장애 효과 연구)

  • 배주현;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.599-611
    • /
    • 1999
  • Now that the plume of point source was suspected to have strong impact on visibility impairment in Pusan, we evaluated visibility impairment impact of the pulme from Pusan Thermo Electric Power Plant in Pusan. Level-1 and-2 analyses were carried out using VISCREEN(Visual Impact Screen model). The emission rates for this Pusan Thermo Electric Power Plant was projected to be 116g/s of nitrogen oxides(as $NO_2$). The source fails the level-1 test with a Plume perceptibility(ΔE) of 30, nearly 15 times the screeing threshold. To characterize worstcase meteorological conditions for level-2 screening, we obtained meteorological data from Mar., 1996 to Feb., 1997 of Pusan Thermo Electric Power Plant. The source fails the level-2 test with a ΔE of 17, nearly 8.5 times the screening threshold. These analyses indicated that adverse visibility impairment could not be ruled out. Therefore a Level-3 analysis was performed using PLUVUE II(Plume Visibility model). As a result, maximum reduction of visual range for 0900LST in winter was 0.9%. Visual impact of the plume from vast point source was judged to be considerable in terms of background visibility of urban area.

  • PDF

The Influence of Long-range Transport on Springtime Nocturnal Ozone Enhancement in Seoul (봄철 서울지역 야간 오존농도 상승에 미치는 장거리 수송의 영향)

  • 오인보;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.503-514
    • /
    • 2004
  • In Seoul metropolitan area, nocturnal variation of surface ozone concentrations observed at 27 monitoring sites from 1998 to 2002 showed that high ozone levels occurred frequently during the spring. Frequency distributions for nighttime ozone indicated that elevated concentrations in spring were influenced by advection of different air mass compared to other seasons. Surface wind analysis during the spring revealed that relatively strong southwesterly winds were associated with nocturnal ozone enhancement, which can be attributed to the regional transport of ozone. In order to identify the origin of nocturnal ozone enhancement in spring, 3-day backward trajectories were calculated by HYSPLIT 4 for the episode days and then classified. The results showed that NW, W, and SW flows, indicating influence of polluted air masses from the China continent, have 51% in a]1 the episode days, which suggest that the nocturnal ozone enhancement can occur under the effect of long-range transport of ozone-laden air mass on a regional scale. Case study of nocturnal ozone maxima associated with long-range transport was discussed in more detail in the light of meteorological conditions. Southwesterly synoptic flow along the outer edge of moving high-pressure system was found to be the important cause of nocturnal ozone maxima in Seoul. This flow could lead to be long-range transport of ozone that had effectively accumulated in the stagnating portion of the system located eastern coast of China. Low atmosphere soundings, backward trajectories, and elevated ozone and CO levels at the back-ground tiles gave evidence for regional effects on nocturnal ozone enhancement In Seoul.

Surface Ozone in The Major Cities of Korea : Trends, Diurnal and Seasonal Variations, and Horizontal Distributions (한반도 주요 대도시지역의 지표오존 특성 : 추세, 일변화, 월변화, 수평분포)

  • 오인보;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.253-264
    • /
    • 2002
  • Surface ozone concentrations measured at 40 monitoring sites in three major cities (Seoul, Busan, and Daegu) of Korea during 1993~2000 were analyzed to understand the characteristics of temporal and spatial distributions. Trends were analyzed for annual mean, 95th percentiles of daily 8-hour maximum and days exceeding 8-h ozone standard of 60 ppb. Three indicators exhibited increasing trends (+0.75 ppb yr$^{-1}$ , +2.20 ppb yr$_{-1}$ , and +5.35 days yr$_{-1}$ on average) throughout the study period at all cities. Diurnal and seasonal variations were the largest in Seoul followed by Daegue and Busan, due to the high photochemical production and titration of ozone (Seoul), strong wind and constant supply of background ozone from the ocean (Busan). In the urban centers and industrial areas at all cities, scavenging of ozone by NO reduces the daily 8-hour maximum ozone by 10 ppb on average. High concentrations of ozone have frequently occurred in downwind eastern (Seoul and Daegu) or northern (Busan) sides of the territory. In particular, the coastal area of Busan had relatively high ozone level due to the local sea land breeze circulation. The results indicated that the temporal and spatial variations of ozone concentration were non -uniform and were closely related to the local environments; emission levels, climates, and geographic locations.

A Study on Bulk Deposition Flux of Dustfall and Insoluble Components in Pusan, Korea (부산지역 강하먼지와 불용성 성분의 침적량에 관한 연구)

  • 김유근;박종길;문덕환;황용식
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.209-216
    • /
    • 2001
  • Dustfall particles were collected by the modified American dust jar (wide inlet bottle type) at 6 sampling sites in Pusan area from March, 1999 to February, 2000. Thirteen chemical species (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Ni, Pb, Si, and Zn) were analyzed by AAS and ICP. The purposes of this study were to estimate qualitatively various bulk deposition flux of dustfall and insoluble components by applying regional and seasonal distribution. Dustfall amount of regional variations were found in order of coastal zone, industrial zone, commercial zone, agricultural zone and residential zone, and seasonal total dustfall had higher concentrations during spring for 6.741 ton/${km}^2$/season, lower concentrations during summer for 1.989 ton/${km}^2$/season, and annual total concentration was 17.742 ton/${km}^2$/year. The regional distributions of enrichment factor show well-defined anthropogenic metals (Cd, Cu, Pb, and Zn) at industrial and agricultural zone, and contribution rate of soil particles were found in order of summer, fall, winter and spring. Factor loading effects of chemical composition of dustfall were found in order of road traffic emission source and combustion processed source, industrial activity source, soil source and marine source.

  • PDF

A Numerical Study of a Effect of the Uniform Flow in Horizontal Convection (일반류가 수평대류에 미치는 영향에 관한 수치연구)

  • Lee, Hwa-Woon;Kim, Yoo-Keun;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.349-360
    • /
    • 1998
  • Effects of uniform flow on a two-dimensional mesoscale horizontal convection were investigated by using the vorticity and thermodynamic equations. For thins purpose, We simulated properties of a thermal convection m a stably stratified Boussinesq flued caused by partial heating at the center of a lower boundary If we don't consider effects of the uniform flow, the convection takes the form of aidsymmetrlc with respect to the z-alds. But when uniform flow Is strong, velocity field and temperature field consist of a sin91e cell structure which spreads upstream side of the partial heating area. The flow pattern for strong uniform flows takes the form of positive temperatue near the ground and negative temperature perturbation soft over the partial heating area, and downward motion directly over the upwind portion of the partial heating area and upward motion on the downstream side. The downstream edge of the upstream cell Is shifted in the downstream direction with the Increase of uniform flow almost linearly.

  • PDF

The Application and Evaluation of Atmospheric Dispersion Models in Pusan Area - Based on TCM2, CDM2.0, ISCLT2 - (부산지역에서의 대기확산모델의 적용 및 평가 -TCM2, CDM2.0, ISCLT2 모델을 중심으로)

  • 방종선;김유근
    • Journal of Environmental Science International
    • /
    • v.5 no.6
    • /
    • pp.699-712
    • /
    • 1996
  • For the efficient control of atmospheric quality, it is so important to predict the influence accurately of which the air pollutant emitted into the atmosphere. Atmospheric dispersion model enables to simulate and grasp the atmospheric condition occurred due to the emission of pollutants. The result of model is largely affected by the amount of emission, the characteristics of physical and chemical process, meteorological input data, and the receptor which the concentration is calculated. The aim of this research, therefore, is to suggest more suitable model in Pusan area than other areas by performing TCM2, CDM2.0 and ISCLT2 models. As the basic work for executing the model, we computed the amount of emission of air pollutants in Pusan at 1992 and analyzed the occurrence frequency of atmospheric stability for recent decade(1985~19941, CDM2.0 showed the similar result relatively with observed value in the case of full year(1992), fall and winter, and ISCLT2 brought more suitable result in spring for Pusan area. As the result of this research, in future, it is necessary for us to develop the numerical model considering the topographical characteristics, to select the proper observation site and to increase the observation site for Pusan.

  • PDF

A study on the atmospheric response to a SST anomaly over the Equatorial Eastern Pacific Ocean with the horizontally fine resolution AGCM (수평조밀격자 GCM을 이용한 적도 태평양상의 SST anomaly에 대한 대기 반응 연구)

  • Moon, Sung-Eui;Ahn, Joong-Bae;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.403-411
    • /
    • 1995
  • The atmospheric responses to a Sea Surface Temperature Anomaly(SSTA) over the equatorial eastern Pacific Ocean have been investigated using the horizontally fine resolution model based on OSU 2-layer Atmospheric General Circulation Model(AGCM). The SSTAS daring the peak phase of 1982-83 El Nino have been applied to the model as the boundary conditions of the experiment. The model simulates the eastward movement of the rising branch of the Walker circulation. That is, the major features associated with the El Nino such as the increase of the precipitation rate over the center of the Pacific and decrease over the Indonesia, and the 500hPa geopotential height anomaly in the middle latitude are properly describes in the fine resolution model experiment. The model results indicate that this horizontally fine resolution UM can successfully simulate the ENSO anomalies and be more effectivelly used for the study of the climate and the climate changes.

  • PDF

Estimation of dose rate using radiative transfer equations (복사전달방정식을 이용한 조사율 추정)

  • 문윤섭;김유근;이영미
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1195-1204
    • /
    • 2002
  • We calculated dose rate using radiative transfer equations to consider radiative processes distinctly. The dose rate at Pohang(36°02'N, 129°23'E) was calculated using measured ozone and meteorological data and two-stream approximations(quadrature, Eddington, delta Eddington, PIFM(practical improved flux method), discrete ordinate, delta discrete ordinate) are used in solving equation. The purpose of this study is to determine the most compatible radiative transfer approximation for simulating the radiative and photochemical processes of atmosphere through comparision between calculated and measured values. Dose rate of the biologically effective irradiance in the region 0.28-0.32 U m showed the highest value when quadrature and Eddington was used and lower value on condition that delta scaling was applied. Correlation coefficient between dose rate at surface using radiation transfer equation and measured UV-B at Pohang was 0.78, 0.79 and 0.81 when delta Eddington, PIFM and delta discrete ordinate were used. Also, in case of above approximations were used, MBE(Mean Bias Error) was within -0.3MED/30min and RMBE(Relative Mean Bias Error) was below 10% between 1200 LST and 1400 LST Approximations which are compatible in estimating radiative process are delta Eddington, PIFM and delta discrete ordinate. Especially, in case that radiative process is considered more detail, delta discrete ordinate increased the number of stream is proper.