• Title/Summary/Keyword: 김용하

Search Result 1,769, Processing Time 0.031 seconds

Compressive Strength Development Properties of Concrete using Sodium based Accelerating Admixtures (나트륨계 기반 조강형 혼화제를 사용한 콘크리트의 압축강도발현 특성)

  • Song, Yeong-Chan;Lee, Tae-Gyu;Kim, Yong-Ro;Seo, Chi-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.259-266
    • /
    • 2018
  • In recent years, the early strength of concrete is important in order to shorten the time of form removal at the construction site. The purpose of this study is to analyze the moment of form removal as investigating the amount of cement contents and the physical properties and strength of the concrete according to types of admixture in the curing temperature of $10^{\circ}C$ for concrete of 21 to 27 MPa. As a result, it was found that compressive strength of concrete could not be secured 5 MPa by 36 hours even if the amount of cement contents were increased to $360kg/m^3$ with plain admixture. Also, it was confirmed that the strength improvement rate was excellent when using the accelerating agent with polycarboxylic acid type, and the moment of compressive strength of 5 MPa was estimated at 30 hours.

Electrochemical Characteristics of an Electric Double Layer Supercapacitor Electrode using Cooked-Rice based Activated Carbon (쌀밥으로 제조된 활성탄을 사용하는 전기이중층형 슈퍼커패시터 전극의 전기화학적 특성)

  • Jo, Un;Kim, Yong-Il;Yoon, Jae-Kook;Yoo, Jung-Joon;Yoon, Ha-Na;Kim, Sung-Soo;Kim, Jong-Huy
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.3
    • /
    • pp.129-137
    • /
    • 2013
  • From the cooked-rice as a raw material, activated carbons throughout a hydrothermal synthesis and vacuum soak of KOH for chemical activation were obtained. Activated carbon electrodes for electric double layer supercapacitors were prepared and electrochemical characteristics were examined. Including the specific surface area by BET method and pore size distribution by NLDFT method, physical properties of activated carbons were investigated by means of SEM, EDS, XRD, and TG analyses. Cycle voltammetry and AC-impedance measurements were conducted to confirm the electrochemical characteristics for the electrodes. From hydrothermal synthesis, $5{\sim}7{\mu}m$ diameters of spherical carbons were obtained. After the activation at $800^{\circ}C$, it was notable for the activated carbon to be the specific surface $1631.8cm^2/g$, pore size distribution in 0.9~2.1 nm, and micro-pore volume $0.6154cm^3/g$. As electrochemical characteristics of the activated carbon electrode in 6M KOH electrolyte, it was confirmed that the specific capacitances of 236, 194, and 137 F/g at the scan rate of 5, 100, and 500 mV/s respectively were exhibited and 91.2% of initial capacitance after 100,000 cycles at 200 mV/s was maintained.

The Mechanical Sensitivity at Interfaces between Bone and Interbody Cage of Lumbar Spine Segments (Lumbar spine 의 뼈와 Interbody cage의 접촉면에서 기계공학적 민감성 고찰)

  • Kim Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.295-301
    • /
    • 2000
  • It is known that among many factors, relative micromotion at bone/implant interfaces can hinder bone ingrowth into surface pores of an implant. Loading conditions, mechanical properties of spinal materials, friction coefficients at the interfaces and geometry of spinal segments would affect the relative micromotion and spinal stability. A finite clement model of the human lumbar spine segments (L4-L5) was constructed to investigate the mechanical sensitivity at the interfaces between bone and cage. Relative micromotion. Posterior axial displacement. bone stress, cage stress and friction force were predicted in changes of friction coefficients, loading conditions. bone density and age-related material/geometric properties of the spinal segments. Relative micromotion (slip distance in a static loading means relative micromotion in routine activity) at the interfaces increased significantly as the mechanical properties of cancellous bone, annulus fibers or/and ligaments decrease or/and as the friction coefficient at the interfaces decreases. The contact normal force at the interfaces decreased as cancellous bone density decreases or/and as the friction coefficient increases A significant increase of slip distance at anterior annulus occurred with an addition of torsion to compressive preload. Relative micromotion decreased with an increase of disc area. In conclusion. relative micromotion, stress response. Posterior axial displacement and contact normal force are sensitive to the friction coefficient of the interfaces, bone density, loading conditions and age-related geometric/material changes.

  • PDF

A study on Waviness of Large Discontinuity using 3D Laser Scanner (3D Laser Scanner를 이용한 대규모 불연속면의 굴곡도 측정 연구)

  • Kim, Yong;Lee, Su-Gon;Kim, Chee-Hwan
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.119-124
    • /
    • 2017
  • The waviness of Large Discontinuity rock is the one of important elements that judges the stability of rock slope. When the waviness of large discontinuity is measured in the field, there are many limitations Therefore this research was carried out to measure waviness of large rock discontinuities using 3D laser scanner to supplement this problem. This research established one 3D model that actual X, Y and Z coordinates through the integrated data gained from one that calculates waviness of base lock using CAD program was compared and analyzed to that of disc-clinometer. As its results, the high reliability of results could be recognized as it belongs to mechanical tolerance $1{\sim}2^{\circ}$ and the results belong to the measured values of Mean DIP and Mean are all within $1^{\circ}$. So, the investigation method of waviness of large discontinuity rock face using 3D laser scanner was verified as more prompt, effective and reliable method than conventional direct site measuring method.

RPC Model Generation from the Physical Sensor Model (영상의 물리적 센서모델을 이용한 RPC 모델 추출)

  • Kim, Hye-Jin;Kim, Jae-Bin;Kim, Yong-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.4 s.27
    • /
    • pp.21-27
    • /
    • 2003
  • The rational polynomial coefficients(RPC) model is a generalized sensor model that is used as an alternative for the physical sensor model for IKONOS-2 and QuickBird. As the number of sensors increases along with greater complexity, and as the need for standard sensor model has become important, the applicability of the RPC model is also increasing. The RPC model can be substituted for all sensor models, such as the projective camera the linear pushbroom sensor and the SAR This paper is aimed at generating a RPC model from the physical sensor model of the KOMPSAT-1(Korean Multi-Purpose Satellite) and aerial photography. The KOMPSAT-1 collects $510{\sim}730nm$ panchromatic images with a ground sample distance (GSD) of 6.6m and a swath width of 17 km by pushbroom scanning. We generated the RPC from a physical sensor model of KOMPSAT-1 and aerial photography. The iterative least square solution based on Levenberg-Marquardt algorithm is used to estimate the RPC. In addition, data normalization and regularization are applied to improve the accuracy and minimize noise. And the accuracy of the test was evaluated based on the 2-D image coordinates. From this test, we were able to find that the RPC model is suitable for both KOMPSAT-1 and aerial photography.

  • PDF

A Study on the Droplet Formation of Liquid Metal in Water-Mercury System as a Surrogate of Molten Salt-Liquid Metal System at Room Temperature (용융염-액체금속 계의 대용물인 물-수은 계에서 액체금속 액적의 생성에 대한 연구)

  • Kim, Yong-il;Park, Byung Gi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.165-172
    • /
    • 2018
  • As an approach for estimation of the droplet size in the molten salt-liquid metal extraction process, a droplet formation experiment at room temperature was conducted to evaluate the applicability of the Scheele-Meister model with water-mercury system as a surrogate that is similar to the molten salt-liquid metal system. In the experiment, droplets were formed through the nozzle and the droplet size was measured using a digital camera and image analysis software. As nozzles, commercially available needles with inner diameters (ID) of 0.018 cm and 0.025 cm and self-fabricated nozzles with 3-holes (ID: 0.0135 cm), 4-holes (ID: 0.0135 cm), and 2-holes (ID: 0.0148 cm) were used. The mercury penetration lengths in the nozzles were 1.3 cm for the needles and 0.5 cm for the self-fabricated nozzles. The droplets formed from each nozzle maintained stable spherical shape up to 20 cm below the nozzle. The droplet size measurements were within a 10% error range when compared to the Scheele-Meister model estimates. The experimental results show that the Scheele-Meister model for droplet size estimation can be applied to nozzles that stably form droplets in a water-mercury system.

A Study on the ZVZCS Three Level DC/DC Converter without Primary Freewheeling Diodes (1차측 환류 다이오드를 제거한 ZVZCS Three Level DC/DC 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kwon, Soon-Do;Kim, Pil-Soo;Gye, Sang-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.66-73
    • /
    • 2002
  • This paper presents ZVZCS(Zero-Voltage and Zero-Current Switching) Three Level DC/DC Converter without primary freewheeling diodes. The new converter presented in this paper used a phase shirt control with a flying capacitor in the primary side to achieve ZVS for the outer switches. A secondary anxiliary circuit which consists of one small capacitor, two small diodes and one coupled inductor, is added in the secondary to provide ZVZCS conditions to primary switches, ZVS for outer switches and ZCS for inner switches. Many advantages include simple secondary auxiliary circuit topology, high efficiency, and low cost make the new converter attractive for high power applications. Also the circulating current flows through the circuit so that it causes the needless coduction loss to be occurred in the devices and the transformer of the circuit The new converter has no primary auxiliary diodes for freewheeling current. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 1[㎾] 50[KHz]IGBT based experimental circuit.

The Relationship Between Mothers' Safety Knowledge and Home Safety Practice (어머니의 안전 지식과 가정 안전 실천간의 관계)

  • Kim, Ji-Young;Youn, Jin-Ju;Kim, Yong-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4240-4247
    • /
    • 2013
  • This purpose of this study was to investigate the difference of safety practice and safety knowledge according to background variables of mothers and the relationship between practice and knowledge in safety of mothers. The subjects were 143 mothers in Iksan city. A questionnaire was made by the researcher on the basis of relevant materials. The data was analyzed by statistical methods such as frequency, Cronbach's ${\alpha}$, descriptive statistics, t-test, ANOVA, Scheffe and Pearson's correlation. The results are as follow: First, mothers' safety knowledge was higher than average. There were significant differences in emergence care, dangerous material, toy safety and young children' developmental character according to mothers' age. There were significant differences in dangerous situation, young children' developmental character and sum score of safety knowledge according to mothers' educational level. So there were significant differences in electrical fire safety, young children's developmental character according to children's age. Second, mothers typically practiced home safety. There were significant differences bathroom, entrance according to mothers' age. And there were significant differences room, kitchen and sum score of safety practice according to children's age. Third, there is no correlation between mothers' safety knowledge and home safety practice.

Characteristics of Dental Restorative Composite Resins Prepared from 2,2-bis- [4- (2-hydroxy-3-rnethacryloyloxy propoxy) phenyl] propane Derivatives and Spiro Orthocarbonate (2,2-비스[4-(2-하이드록시-3-메타크릴로일옥시프로폭시)페닐] 프로판 유도체와 스파이로 오쏘카보네이트가 포함된 치아 수복재의 특성)

  • Kim Yong;Lee Juyeon;Park Kwangyong;Kim Chang Keun;Kim Ohyoung
    • Polymer(Korea)
    • /
    • v.28 no.5
    • /
    • pp.426-432
    • /
    • 2004
  • To reduce volumetric shrinkage of the commercially available polymeric dental composite during curing reaction, (2,2-bis [4-(2-hydroxy-3-methacryloyloxy propoxy) phenyl] propane) (bis -GMA) derivatives, i.e., (2,2-bis[3-methyl, 4-(2-hydroxy-3-methacryloyloxy propoxy) phenyl] propan) (DMBis-GMA) and (2,2-his [3,5-dimethyl ,4- (2-hydroxy-3-methacryloyloxy propoxy) phenyl] propane) (TMBis-GMA) were synthesized and then new dental composite resin composed of Bis-GMA derivatives, diluent, spiro orthocarbonate (SOC), and inorganic filler was produced. Among the Bis-GMA derivative/Bis-GMA derivative/diluent mixtures, Bis-GMA/ TMBis-GMA/TEGDMA mixture exhibited the lowest volumetric shrinkage. Volumetric shrinkage of this mixture was further reduced by adding SOC. Volumtric shrinkage of dental composite prepared from commercially available resin monomer mixture was $2.5\%$, while that prepared from resin monomer mixture having minimum volumetric shrinkage was reduced to $0.7\%$. Mechanical strength of this dental composite was nearly the same with that of commercial products but the time required for the curing reaction was retarded.

Pulmonary Resection for Invasive Pulmonary Aspergillosis in Hematological Malignancy Patients (혈액암 환자에서 합병된 침습성 폐아스페르길루스증의 수술적 치료)

  • Sa, Young-Jo;Kim, Yong-Han;Nam, Sang-Yong;Sim, Sung-Bo;Lee, Sun-Hee;Park, Jae-Kil
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.617-623
    • /
    • 2007
  • Background: Invasive pulmonary aspergillosis, a frequent fungal infection in immunocompromised patients, is known to have a poor prognosis despite the use of antifungal therapy in leukemic patients. We studied the outcome of surgical resection of invasive pulmonary aspergillosis where bleeding tendency, localized recurrence of infection, and incidence could be reduced. Material and Method: We retrospectively reviewed 14 patients with a hematological malignancy where invasive pulmonary aspergillosis was diagnosed during the 10 years between 1998 and 2007. From the medical records, we reviewed the type and treatment of the hematological malignancy, including the diagnostic methods of invasive pulmonary aspergillosis, the preoperative hematological conditions and their management, and the surgical methods and records. We also analyzed the development of postoperative complications and patient mortality, the recurrence of postoperative invasive pulmonary aspergillosis, and if the patients had a bone marrow transplant. Result: Fourteen patients with invasive pulmonary aspergillosis and a hematological malignancy underwent a pulmonary lobectomy. One patient had a complication of bronchopleural fistula, but there were no other serious complications such as bleeding or wound infection, and none of the patients died postoperatively. Conclusion: We have shown that pulmonary lobectomy is a safe and effective therapy for invasive pulmonary aspergillosis in patients with hematological malignancies that allow further treatment of the hematological malignancy.