• Title/Summary/Keyword: 김기웅

Search Result 254, Processing Time 0.026 seconds

Cytoprotective Effect of a Neutrase Enzymatic Hydrolysate Derived from Korea Pen Shell Atrina pectinata Against Hydrogen Peroxide -Induced Oxidative Damages in Hepatocytes (산화적 손상에 대한 키조개(Atrina pectinata) 효소 가수분해물의 간세포 보호 효과)

  • Han, Eui Jeong;Shin, Eun-Ji;Kim, Kee-Woong;Ahn, Ginnae;Bae, Tae Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.1
    • /
    • pp.123-131
    • /
    • 2020
  • In this study, we investigated the protective effects of a Neutrase enzymatic hydrolysate derived from Korea pen shell Atrina pectinata (APN) against hydrogen peroxide (H2O2)-induced oxidative damage in hepatocytes. First, we confirmed that APN has antioxidant activities by scavenging 2,2-azino-bis (3-ethylbenzthiazoline)-6-sulfonic acid radical (ABTS+) and H2O2 and increasing oxygen radical absorbance capacity (ORAC) value. Also, the treatment of APN increased the cell viability by reducing the intracellular reactive oxygen species (ROS) production in H2O2-stimulated hepatocytes. In addition, APN decreased the sub-G1 DNA contents and the apoptotic body formation increased by H2O2 stimulation. Moreover, APN modulated the protein expression of apoptosis related molecules (Bcl-2, Bax and p53) by suppressing the activation of nuclear factor NFkB and ERK/p38 signaling in H2O2-stimulated hepatocytes. Furthermore, APN led to the activation of Nrf2/HO-1signaling known as antioxidant systems. These results suggest APN protects hepatocytes against oxidative damages caused by H2O2 stimulation.

A Comparative Study on the Institute Time Clauses-Hulls 1995, American Institute Hulls Clauses 1977 and Japanese Hull Standard Clauses, 1990 (영국.미국.일본선박보험약관의 비교연구 -오염손해, 보험사고 발생의 통지의무, 신구교환차익공제 및 중복보험에 관한 규정을 중심으로-)

  • Hong, Sung-Hwa;Kim, Ki-Ung
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.66-77
    • /
    • 2002
  • Generally hull insurance is undertaken by mean of a contract of hull insurance. A contract of hul1 insurance here is a contract whereby the insurer undertakes to indemnify the assured against the loss and damage to the vessel mused by maritime perils. A contract of hull insurance is consists of printed main insurance clauses and a clause includes many sub-clauses. Now the Institute Time Clauses-Hulls (hereunder refer to as "English hull insurance clauses"made by the Institute of London Underwriters is much used as the standard from or basic from by many countries ail over the world Now Korean insurance companies hue not made our their own hull insurance clauses, they have just adopted the made-out English hull insurance clauses and the english law and practice to solve the problem related to marine insurance. On the other hand, the United States of America and Japan have made out their own hull insurance clauses based on English hull insurance clauses and used the clauses for many years. Now American is using American Institute Hull Clauses(hereunder refer to as "American hul1 insurance clauses"as its own clauses which was made out by American Institute of Marine Underwriters in 1977 and Japan is also wing its own clauses named Japanese Hull Standard Clauses(hereunder refer to as "Japanese hull clauses") which was made out by japanese Hull Insurance Association in 1990. Therefore the purpose of this study is not only to make a comparative study on English hull insurance clauses 1995, American hull insurance clauses 1977 and Japanese hull clauses l990, but also to supply on some legal materials necessary for Korea to establish and perform our own hull insurance clauses.

Subsyndromal Depression (아증후군적 우울증)

  • Park, Joon-Hyuk;Kim, Ki-Woong
    • Korean Journal of Biological Psychiatry
    • /
    • v.18 no.4
    • /
    • pp.210-216
    • /
    • 2011
  • Subsyndromal depression (SSD) is found to be more prevalent than major depressive disorder (MDD) and minor depressive disorder (MnDD). SSD is also associated with adverse clinical outcomes, increased risk of suicide, increased social dysfunction and disability, increased risk for future mood disorders, and increased uses of medical and mental health services. DSM-IV diagnostic criteria are not suitable for capturing SSD. Although there is no agreement on gold standard to define SSD so far, three definitions of SSD are available. First, SSD is defined as having two or more current depressive symptoms without core depressive symptoms (depressive mood or loss of interest) and with time threshold (most of the day and nearly every day over at least two weeks). Second, SSD is defined as having two or more current depressive symptoms with core depressive symptoms and without time threshold. Third, SSD is defined by using cutoff points of depression rating scales. SSD may represent a prodromal, residual, or interepisode symptomatic state in the course of MDD and MnDD. More than a half of SSD patients became any type of depressive disorders (SSD, MnDD and MDD) at 1 year. SSD may represent a discrete category of its own, without prior or consequent episodes of MDD. Considering clinical significance of SSD such as its high prevalence, significant psychosocial impairment and chronicity and serious outcomes, researchers and clinicians should be more vigilant in capturing and caring for patients with SSD.

Behavior of Variable Cross-Section Soft Ground Reinforced Foundation in Soft Grounds (연약지반에 적용된 변단면 연약지반보강기초의 거동분석)

  • Kim, Khi-Woong;Kim, Dong-Wook;Jo, Myoung-Su
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.89-96
    • /
    • 2016
  • Compressive axial behavior of the variable cross-section soft ground reinforced foundation is investigated from the field load test results at ${\bigcirc}{\bigcirc}$ construction site in Incheon city. Variable cross-section soft ground reinforced foundation is a type of partial-displacement pile formed by mixing bidding material with in situ soils to obtain a rigid and strong variable cross-section column in a relatively soft ground. The foundations are usually constructed as a group; however in this study, only single foundation was installed and tested under compressive axial load on foundation head. For the comparison of the variable cross-section soft ground reinforced foundation axial behavior, behavior of typical Pretensioned spun high strength concrete (PHC) pile constructed on a relatively soft ground near the surface was analyzed. It was concluded that variable cross-section soft ground reinforced foundation efficiently resists against axial load with sufficient stiffness and strength within a considerable range of axial load magnitude.

PCDDs and DFs concentrations from the fly ash and bottom ash of industrial waste incinerators in Korean (산업폐기물 소각장의 바닥재와 비산재에서 PCDDs와 DFs 농도)

  • Kim, Ki-Woong;Won, Yong Lim;Ko, Kyung Sun;Choi, Yoon Jung;Lee, Sung Kwang
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.347-351
    • /
    • 2014
  • This study determinated the polychlorinated dibenzo-${\rho}$-dioxins and dibenzofurans (PCDDs and DFs) in fly ash and bottom ash of industrial waste incinerators. Experimental results showed that average PCDDs and DFs concentrations in fly ash were 4.5063 and 13.004 ng-TEQ/g, and in bottom ash were 0.2367 and 0.0993 ng-TEQ/g, respectively. Predominant congener in TEQ of PCDDs/DFs from fly ash were 1,2,3,4,6,7,8-HpCDD, OCDD, 2,3,4,6,7,8-HxCDF, 2,3,4,7,8-PeCDF and in bottom ash were 1,2,3,7,8-PeCDD and 2,3,4,7,8-PeCDF.

Is It Necessary to Use Dextran in Free Flap Surgery? (유리피판술에서 덱스트란의 사용이 필요한가?)

  • Ahn, Hee Chang;Kim, Kee Woong;Lee, Young Jin;Kim, Yeon Hwan
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.393-396
    • /
    • 2009
  • Purpose: Low - molecular - weight dextran is one of the most frequently used antithrombotic agents in microvascular surgery, but there is controversy if it has the real benefit in the clinical aspects. The purpose of this study was to evaluate the effect associated with postoperative use of low - molecular - weight dextran in breast reconstruction by free TRAM flap patients. Methods: From January 2002 to October 2008, we reconstructed 88 cases of postmastectomy deformity using the free TRAM flap. The 88 cases were divided into two groups : a group with no use of dextran(66 patients, control group, Group A) and a postoperative low - molecular weight dextran loaded group(22 patients, Group B). We assessed number of flap survival, rate of complication like hematoma or seroma, total amount of drainage from operative wound, duration of drainage, and amount of transfusion in each group. Results: There was no total flap loss and every flap was survived. Total amount of drainage for post - operative 5 days were 857 ml in group A and 1101 ml in group B. Drain was kept for average of 7.3 days in group A and 8.7 days in group B. Packed red cell transfusions were made in average of 3.3 units for group A and 3.0 units for group B. Group B showed significantly higher values in former 2 comparative parameters than group A. Conclusion: There was no definitive advantage of anticoagulants in elective free - flap surgery in terms of success rate. However, groups with using anticoagulants had the increased bleeding tendency in immediate postoperative period. The routine use of anticoagulants in elective free - flap surgery should be reconsidered with postoperatively less bleeding and early recovery.

Role of Magnetocardiography in Emergency Room (응급실에서 심자도의 역할)

  • Kwon, H.;Kim, K.;Kim, J.M.;Lee, Y.H.;Kim, T.E.;Lim, H.K.;Park, Y.K.;Ko, Y.G.;Chung, N.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.40-45
    • /
    • 2006
  • In emergency rooms, patients with acute chest pain should be diagnosed as quickly as possible with higher diagnostic accuracy for an appropriate therapy to the patients with acute coronary syndrome or for avoiding unnecessary hospital admissions. At present, electrocardiography(ECG) and biochemical markers are generally used to detect myocardial infarction and coronary angiography is used as a gold standard to reveal the degree of narrowing of coronary artery. Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool fur the detection of cardiac electrical abnormality associated with myocardial ischemia. In this study, we examined whether the MCG can be used fur the detection of coronary artery disease(CAD) in patients, who were admitted to the emergency room with acute chest pain. MCG was recorded from 36 patients admitted to the emergency room with suspected acute coronary syndrome. The MCG recordings were obtained using a 64-channel SQUID MCG system in a magnetically shielded room. In result, presence of CAD could be found with a sensitivity of 88.2 % in patients with acute chest pain without 57 elevation in ECG, demonstrating a possible use in the emergency room to screen CAD patients.

  • PDF

Diagnosis of Coronary Artery Disease in Patients with Chest Pain by Means of Magnetocardiography (흉통환자에서 심자도를 이용한 관상동맥질환의 진단)

  • Kwon, H.;Kim, K.;Kim, J.M.;Lee, Y.H.;Kim, T.E.;Lim, H.K.;Park, Y.K.;Ko, Y.G.;Chung, N.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.46-53
    • /
    • 2006
  • Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool for the detection of cardiac electrical abnormality associated with myocardial ischemia. In our previous study, we have proposed a new classification method of MCG parameters, based on the different populations of the parameters between coronary artery disease(CAD) patients, symptomatic patients and healthy volunteers. We used four parameters, representing the directional changes of the electrical activity in the period of an R-ST-T interval. In patients with chest pain and without ST-segment elevation, who were selected consecutively from all patients admitted to the hospital in 2004, the patients with CAD could be classified with a higher sensitivity than conventional methods, showing that the proposed method can be useful for the diagnosis of CAD with MCG. In this study, we examined the validity of the algorithm with the prior probability distribution in diagnosis of new patients admitted to the hospital in 2005. In the results, presence of CAD could be found with sensitivity and specificity of 81.3% and 71.4%, respectively, in patients with chest pain and non-diagnostic ECG findings.

  • PDF

Development of a Magnetoencephalograph System for Small Animals (소동물용 뇌자도 측정 시스템 개발)

  • Kim, J.E.;Kim, I.S.;Kang, C.S.;Kwon, H.;Kim, J.M.;Lee, Y.H.;Kim, K.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/$Hz^{1/2}$/cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

Review of SQUID Sensors for Measuring Magnetocardiography (심자도 측정을 위한 SQUID 센서 기술의 개발 현황)

  • Lee, Y.H.;Kim, J.M.;Yu, K.K.;Kim, K.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.