• Title/Summary/Keyword: 길이 재현성

Search Result 175, Processing Time 0.036 seconds

Development of Radiological Examination Aids for Accurate Lower Extremity Length Measurement (정확한 하지 길이 측정을 위한 방사선 검사 보조기구 개발)

  • Hee-min Ahn;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.6
    • /
    • pp.673-680
    • /
    • 2024
  • The purpose of the study is to produce an auxiliary device that can measure accurate actual values during radiological examination where the length of the lower extremities is different, and to provide accurate quantitative values for establishing surgical plans. After manufacturing the device, a height and length reproducibility experiment was conducted, and a quantitative evaluation was performed using the measured values. A qualitative evaluation was conducted with 10 orthopedic residents to evaluate its usefulness. In the height reproducibility test, the existing method was statistically significant at p<0.05 in all items except the 1.0 cm experiment, and the manufactured assistive device was not statistically significant at p≧0.05. In the length reproducibility test, p<0.05 was found for both the existing and manufactured assistive device methods. In the qualitative evaluation, the reliability value was 0.690 and the average value ranged from 4.30 ± 0.94 to 4.90 ± 0.31. In conclusion, I think that if the surgical plan is made by expressing the difference in leg length as a quantitative value by using the manufactured auxiliary device, it can greatly contribute to the completeness of the surgery.

biomolecule DNA detection using Microchip with amperometry (전류법을 이용한 생체물질 DNA 검출 마이크로칩)

  • Joo, Gi-Sung;Jha, Sandeep Kumar;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1553_1554
    • /
    • 2009
  • 마이크로칩에서의 생체물질 분석에 있어서 재현성은 매우 중요한 사항이다. 이전부터 많은 연구자들에 의해서 분석시 재현성을 향상시키고자 많은 연구가 선행되었다. 재현성을 향상시킬 수 있는 한 방안으로 겔 전기영동이 이용되고 있다. 본 연구에서도 겔 전기영동을 마이크로칩에 접목시켜 재현성을 향상시키는 실험을 진행하였다. DNA 시료로 100bp부터 1500bp 길이의 DNA 단편들을 사용한 결과 인산완충식 염수 (PBS)만을 사용하였을 경우보다 인산완충식염수(PBS)와 5% 폴리아크릴아미드 겔 (5% polyacrylamide)과 같이 사용하였을 경우 더 향상된 재현성을 확보하였다.

  • PDF

Validity, Reliability and Reproducibility of Space Analysis using Digital Model taken via Model Scanner and Intraoral Scanner: An In vivo Study (모델 스캐너와 구내 스캐너로 획득한 디지털 모형에서 시행한 공간 분석의 타당도, 신뢰도, 재현성 평가)

  • Park, Seohyun;Kim, Jongsoo;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.176-187
    • /
    • 2020
  • The purpose of this study is to evaluate validity, reliability and reproducibility of tooth width (TW), arch length (AL) and arch length discrepancy (ALD) measured on a digital model taken via 3-dimensional model scanner and intraoral scanner compared to a plaster model. A total of 30 patients aged 12 to 18 were eligible for the study. 3 types of models were acquired from each patient: a conventional plaster model (P), a model scanned digital model (MSD) taken via Freedom UHD® and an intraoral scanned digital model (ISD) taken via CS3600® in-vivo. The reliability of TW and AL in each group was evaluated using Pearson's correlation coefficient, while the reproducibility was evaluated with intraclass correlation coefficient. The validity of space analysis was assessed by paired t-test. As a result, all measurements of P, MSD and ISD groups showed favorable reliability and reproducibility. Most of measurements for space analysis in MSD group and TW in ISD group also presented high validity. AL and ALD presented statistically significant difference between P and ISD group. The validity of measurements of space analysis in ISD group was short in doubt to valid, but clinically acceptable. Both MSD and ISD are clinically acceptable to use for space analysis but clinician should be aware that errors can be found using a digital model.

Morphological Feature Analysis of Breast Nuclei for Diagnosis of Breast Cancer (유방질환 진단을 위한 유방 종양 세포핵의 형태학적 특성 비교.분석)

  • 황해길;최현주;최흥국;윤혜경
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.06a
    • /
    • pp.91-94
    • /
    • 2001
  • 유방 질만 분석을 위한 병리진단에서는 암종세포의 세관형성 정도와 핵의 다형성과 유사분말정도를 기준으로 하여 나누는 방법이 용이하고 재현성이 높다. 그 중에서도 세포핵의 크기와 다형성, 핵과 세포질의 비율은 양성종양과 악성종양을 분류하는데 있어서 중요한 요소중의 하나이다. 그러므로 본 논문에서는 유방 질단 영상에서 세포핵을 추출하여, 핵의 형태학적 특징값인 핵의 연적 둘레, 가로·세로(장·단축)의 길이를 구하고 핵과 세포질의 비율을 계산한 후, 추출한 형태학적 특성 칸들이 양성종양과 악성종양으로 분류하는데 있어서 유의한 특성 값인지 비교·분석하였다.

  • PDF

Study of Variation of Internal Taget Volume between 4DCT and Slow-CT in Respiratory Patterns Using Respiratory Motion Phantom (호흡 동조 구동 팬톰을 이용한 호흡패턴에 따른 4DCT, Slow-CT의 내부표적체적 변화 연구)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Ji, Young Hoon;Kim, Mi-Sook;Yoo, Hyoung Jun;Kim, Chan Hyeong;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.53-63
    • /
    • 2014
  • The objective of this study is to investigate the difference of ITV lengths and ITVs between 4DCT and Slow-CT images according to respiratory patterns using a respiratory motion phantom. The respiratory periods 1~4 s and target motion 1~3 cm were applied on each respiratory pattern. 4DCT and Slow-CT images were acquired for 3 times. 4DCT and Slow-CT ITVs were measured with contouring the target in the Eclipse RTP system. The measured ITV lenghts and ITVs in 4DCT and Slow-CT images were compared to the known values. For the ITV lengths and ITVs in the 4DCT, the difference of them were reduced as the respiratory period is longer and target motion is shorter. For the Slow-CT, there was same tendency with change in 4DCT ITV lengths and ITVs about target motion. However, the difference of ITV lengths and ITVs for the respiratory periods were the lowest in respiratory period 1 second and different slightly within respiratory period 2-4 seconds. According to the respiratory patterns, pattern A had the highest reproducibility. Pattern B, C and D were showed the difference similar to each other. However, for pattern E, the reproducibility was the lowest compared with other four patterns. The difference of ITV lengths and ITVs between Slow-CT and 4DCT was increased by increasing the respiratory periods and target motion for all respiratory patterns. When the difference of Slow-CT ITV lengths and ITVs were compared with that of 4DCT ITV lengths and ITVs, Slow-CT ITV lengths and ITVs were approximately 22 % smaller than 4DCT, and the representations of target were different in each pattern. In case of pattern A, B and C, length difference was 3 mm at S (superior) and I (inferior) direction, and the length difference of pattern D was 1.45 cm at only "I" direction whereas the length difference of pattern E was 5 mm longer in "S" direction than "I" direction. Therefore, the margin in SI directions should be determined by considering the respiratory patterns when the margin of Slow-CT is compensated for 4DCT ITV lengths. Afterward, we think that the result of this study will be useful to analyze the ITV lengths and ITVs from the CT images on the basis of the patient respiratory signals.

Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue (소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가)

  • Choi, Kyunghwa;Kim, Misun;Lee, Koeun;Nam, Okhyung;Lee, Hyo-seol;Choi, Sungchul;Kim, Kwangchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2020
  • The purpose of this study was to evaluate the accuracy and precision of the three-dimensional (3D) imaging system of children's facial soft tissue by comparing linear measurements. The subjects of the study were 15 children between the ages of 7 and 12. Twenty-three landmarks were pointed on the face of each subject and 16 linear measurements were directly obtained 2 times using an electronic caliper. Two sets of 3D facial images were made by the 3D scanner. The same 16 measurements were obtained on each 3D image. In the accuracy test, the total average difference was 0.9 mm. The precision of 3D photogrammetry was almost equivalent to that of direct measurement. Thus, 3D photogrammetry by the 3D scanner in children had sufficient accuracy and precision to be used in clinical setting. However, the 3D imaging system requires the subject's compliance for exact images. If the clinicians provide specific instructions to children while obtaining 3D images, the 3D device is useful for investigating children's facial growth and development. Also the device can be a valuable tool for evaluating the results of orthodontic and orthopedic treatments.

The Impact of Descriptor Characteristics on the Accuracy of Neural Network Potentials for Predicting Material Properties (Descriptor 특성이 신경망포텐셜의 소재 물성 예측 정확도에 미치는 영향에 관한 연구)

  • Jeeyoung Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.378-384
    • /
    • 2023
  • In this study, we aim to derive the descriptor vector conditions that can simultaneously achieve the efficiency and accuracy of artificial Neural Network Potentials (NNP). The material system selected is silicon, a highly applicable material in various industries. Atomic structure-dependent energy data for training artificial neural networks were generated through density functional theory calculations. Behler-Parrinello type atomic-centered symmetric functions were employed as descriptors, and various length vector NNPs were generated. These NNPs were applied to reproduce the structure and mechanical properties of silicon materials in molecular dynamics simulations. In our findings, the minimum vector length for achieving both learning and computational efficiency while maintaining property reproducibility is approximately 50. It was also observed that, for the same conditions, incorporating more angle-dependent symmetric functions into the descriptor vector, could enhance the accuracy of NNP. Our results can provide guidelines for optimizing the conditions of descriptor vectors to achieve both efficiency and accuracy of NNP, simultaneously.

An Alleviative Device of Smooth Rotating Gate (완충회전수문의 충격 완화장치)

  • Yoo, Dong-Hoon;Lee, Tae-Hee;Bae, Deok-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.546-550
    • /
    • 2007
  • 수중보는 하천, 하수관 또는 인공수로에 건기시 유지수량을 확보할 목적으로 설치되며 보통 10년 주기 내외의 평균 강우량에 맞추어 그 용량을 결정한다. 수처리를 위한 장치의 규모는 적정한 재현기간에 맞추어 설계하고, 재현기간을 초과하여 강우가 발생할 경우 강우 유입을 우회시켜 경제성을 확보할 수 있어야 한다. 따라서 완충회전수문은 초과하는 수량을 우회 또는 통과시킬 목적으로 개발되었으며 기존 연구에서 실내 및 현장 실험 모형을 제작하여 여러 차례 실험을 토대로 한계수심 및 충격량을 이론적으로 산정하고 현장 적용성을 검증한 바 있다. 본 연구에서는 수문의 개 폐시 원형실린더에 부착되어 있는 날개의 길이 및 개수 변이에 따른 항력의 영향으로 충격량을 측정하여 현장에 보다 적합한 완충회전수문의 최적설계방안을 제시하고자 한다.

  • PDF

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.

The composition control of ITO/PET by Plasma Emission Monitors (PEM을 이용한 ITO/PET film 조성 제어)

  • 한세진;김용한;김영환;이택동
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.213-213
    • /
    • 1999
  • 현재 LCD용 기판재료는 ITO/glass를 전극으로 사용하고 있다. 그러나 유리기판은 무겁고 깨지기 쉽기 때문에 사용상 곤란한 점이 많다. 최근 flexible하고 가공성 및 생산성이 우수한 플라스틱한 ITO를 성막하여 EL용, Touch panel, plastic LCD용 사용하려는 시도로, roll-to-roll 연속 스퍼터링에 의한 ITO성막공정에 대한 연구가 최근 활발하게 이루어지고 있다. 폴리머는 유리에 비해 Tg 온도가 낮고, 기판으로부터의 수분 및 여러 종류의 가스방출이 심하기 때문에 유리와는 달리 ITO막의 제조에 있어 큰 차이점이 있다. 따라서, 폴리머에 반응성 스퍼터링을 하기 위해서는 표면처리가 중요한 변수가 되며, roll to roll sputter로 ITO 필름을 얻기 위해서는 폭과 길이 방향으로 균일한 막을 얻는 것이 중요하다. 두께 75$\mu\textrm{m}$, 폭 190mm, 길이 400m로 권취된 광학용 Polyethylene terephthalate(PET:Tg:8$0^{\circ}C$)위에 In-10%Sn의 합금타겟과 Unipolar pulsed DC power supply를 사용하여 반응성 마그네트론 스퍼터링 방법으로 0.2m/min의 속도로 연속 스퍼터링 하였다. PET를 Ar/O2 혼합가스로 플라즈마 전처리를 한 후, AFM, XPS를 이용하여 효과를 분석을 하였고, 성막전에 가스방출을 막기 위해 TiO를 코팅하였다. Pilot 연속 생산공정에서 재현성을 위해 PEM(Plasma Emission Monitor)의 optical emission spectroscopy를 이용, 금속과 산화물의 천이구역에서 sprtter된 I/Sn 이온과 산소 이온의 반응에 의한 최적의 플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.

  • PDF