• Title/Summary/Keyword: 기하학적 인수

Search Result 20, Processing Time 0.026 seconds

Analysis of Geometrical Relations of 2D Affine-Projection Images and Its 3D Shape Reconstruction (정사투영된 2차원 영상과 복원된 3차원 형상의 기하학적 관계 분석)

  • Koh, Sung-Shik;Zin, Thi Thi;Hama, Hiromitsu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.1-7
    • /
    • 2007
  • In this paper, we analyze geometrical relations of 3D shape reconstruction from 2D images taken under anne projection. The purpose of this research is to contribute to more accurate 3-D reconstruction under noise distribution by analyzing geometrically the 2D to 3D relationship. In situation for no missing feature points (FPs) or no noise in 2D image plane, the accurate solution of 3D shape reconstruction is blown to be provided by Singular Yalue Decomposition (SVD) factorization. However, if several FPs not been observed because of object occlusion and image low resolution, and so on, there is no simple solution. Moreover, the 3D shape reconstructed from noise-distributed FPs is peturbed because of the influence of the noise. This paper focuses on analysis of geometrical properties which can interpret the missing FPs even though the noise is distributed on other FPs.

A Formulation for Response Variability of Plates Considering Multiple Random Parameters (다중 불확실 인수를 고려한 평판의 응답변화도 산정 정식화)

  • Noh, Hyuk-Chun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.789-799
    • /
    • 2007
  • In this paper, we propose a stochastic finite element formulation which takes into account the randonmess in the material and geometrical parameters. The formulation is proposed for plate structures, and is based on the weighted integral approach. Contrary to the case of elastic modulus, plate thickness contributes to the stiffness as a third-order function. Furthermore, Poisson's ratio is even more complex since this parameter appears in the constitutive relations in the fraction form. Accordingly, we employ Taylor's expansion to derive decomposed stochastic field functions in ascending order. In order to verify the proposed formulation, the results obtained using the proposed scheme are compared with those in the literature and those of Monte Carlo analysis as well.

Statistical Behavior of RC Cooling Tower Shell due to Shape Imperfection (철근콘크리트 냉각탑의 형상불완전에 의한 확률론적 거동)

  • 최창근;노혁천
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.147-158
    • /
    • 2000
  • For the large scale reinforced concrete cooling tower shells, the shape imperfection can be introduced due not only to mistakes in the process of construction but also to the long term behavior of concrete. The shape imperfection evokes the additional responses such as displacements and stresses in addition to the design values. In this study, the statistical behavior of the RC cooling tower shell due to the shape imperfection is investigated using the Monte Carlo simulation. The radius of cooling tower and the shell thickness are adopted as the parameters which cause the shape imperfection. The shape imperfection is modeled as a stochastic field rather than the local one of axisymmetric or bulge type of imperfection. The randomness in the radius is shown to be more affecting the structural responses than the randomness in the shell thickness. In addition to the geometrical randomness, the effect of randomness in the modulus of elasticity on the structural response is also investigated and compared with that of the geometrical ones.

  • PDF

Acceptance Test and Quality Control of Radiotherapy Treatment Simulator (의료용 모의치료기의 품질관리에 관한 연구)

  • 신동호;박성용;신동오;최진호;김유현;권수일
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • The simulator which has a identical geometry with radiotherapy equipments, is a essential equipment to accomplish optimized radiotherapy plan through simulation by using diagnostic low energy X-ray. A Radiotherapy simulator has a combined technology from the therapeutic and diagnostic radiology and needs a periodical test for mechanical and optical properties, X-ray generator, image intensifier of simulator to keep the proper maintenance and radiation safety. Hence, tests were done and classified as i) mechanical and optical parameter for the gantry, collimator, and couch ii) key performance of the X-ray generator such as a kVp, mAs, and timer iii) performance of the image intensifier such as a resolution and contrast for three kinds of simulator, common use in clinic. The above result of tests will be applied to the acceptance test and periodical quality assurance procedure.

  • PDF

A Performance Evaluation of Diagnostic Display System by AAPM TG18 (AAPM TG18에 의한 진단용 CRT 디스플레이 시스템의 성능 평가)

  • Kim, H.J.;Jung, H.J.;Min, D.K.;Hong, J.O.;Kim, Y.N.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • 디지털 영상 검출기와 디스플레이 기술의 발달과 의료영상전달시스템(PACS)의 출현은 전통적 필름방식에 비하여 디지털 방식으로 방사선과 영상을 획득하고 전송, 저장하는 매우 효과적인 수단을 제공하고 있다. 2002년 8월, 연세의료원 세브란스병원은 진단 영상 판독 목적으로 18 대의 CRT(Braco View, Belgium)와 32대의 평판 LCD(Totoku Electric Co., Ltd., Japan) 디스플레이 장치를 GE full-PACS(GE 메디칼시스템코리아 : GEMSK)와 연계하여 설치 완료하였다. 본 연구에서, 기하학적 왜곡, 반사, 휘도 반응, 휘도 균일도, 분해능, 노이즈,베일링 글레어, 칼라 균일도 항목들을 AAPM TG18 보고서 9.0에 따라서 시각적 그리고 부분적으로는 정량적인 방법으로 인수검사를 실시하여 보고한다. 사용된 장비는 색도계로도 사용되는 간편한 휘도계, TG18 테스트 패던, AAPM Tg18 AT plug-in software(Barco View Ltd., Kortrijk, Belgium)이었다. 칼라 균일도를 제외한 모든 테스트 결과는 AAPM TG18에서 권고하는 기준에 일치하였으며 진단 영상 판독에 사용하기에 전적으로 수락할 수 있는 성능이었다. 결론으로, 사용된 인수검사는 단지 인수 검사 표준을 제공하는 것 뿐만 아니라 품질검사(QC)의 지침, 판독 환경의 최적화 그리고 교체 시기나 업그레이드 시기를 결정하여주는 중요한 역할을 할 수 있을 것이다.

  • PDF

Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source (미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용)

  • Ahn, Woo-Sang;Jang, Won-Woo;Park, Sung-Ho;Jung, Sang-Hoon;Cho, Woon-Kap;Kim, Young-Seok;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.190-197
    • /
    • 2011
  • Currently, the dose distribution calculation used by commercial treatment planning systems (TPSs) for high-dose rate (HDR) brachytherapy is derived from point and line source approximation method recommended by AAPM Task Group 43 (TG-43). However, the study of Monte Carlo (MC) simulation is required in order to assess the accuracy of dose calculation around three-dimensional Ir-192 source. In this study, geometry factor was calculated using segmented sources integration method by dividing microSelectron HDR Ir-192 source into smaller parts. The Monte Carlo code (MCNPX 2.5.0) was used to calculate the dose rate $\dot{D}(r,\theta)$ at a point ($r,\theta$) away from a HDR Ir-192 source in spherical water phantom with 30 cm diameter. Finally, anisotropy function and radial dose function were calculated from obtained results. The obtained geometry factor was compared with that calculated from line source approximation. Similarly, obtained anisotropy function and radial dose function were compared with those derived from MCPT results by Williamson. The geometry factor calculated from segmented sources integration method and line source approximation was within 0.2% for $r{\geq}0.5$ cm and 1.33% for r=0.1 cm, respectively. The relative-root mean square error (R-RMSE) of anisotropy function obtained by this study and Williamson was 2.33% for r=0.25 cm and within 1% for r>0.5 cm, respectively. The R-RMSE of radial dose function was 0.46% at radial distance from 0.1 to 14.0 cm. The geometry factor acquired from segmented sources integration method and line source approximation was in good agreement for $r{\geq}0.1$ cm. However, application of segmented sources integration method seems to be valid, since this method using three-dimensional Ir-192 source provides more realistic geometry factor. The anisotropy function and radial dose function estimated from MCNPX in this study and MCPT by Williamson are in good agreement within uncertainty of Monte Carlo codes except at radial distance of r=0.25 cm. It is expected that Monte Carlo code used in this study could be applied to other sources utilized for brachytherapy.

Camera Extrinsic Parameter Estimation using 2D Homography and Nonlinear Minimizing Method based on Geometric Invariance Vector (기하학적 불변벡터 기탄 2D 호모그래피와 비선형 최소화기법을 이용한 카메라 외부인수 측정)

  • Cha, Jeong-Hee
    • Journal of Internet Computing and Services
    • /
    • v.6 no.6
    • /
    • pp.187-197
    • /
    • 2005
  • In this paper, we propose a method to estimate camera motion parameter based on invariant point features, Typically, feature information of image has drawbacks, it is variable to camera viewpoint, and therefore information quantity increases after time, The LM(Levenberg-Marquardt) method using nonlinear minimum square evaluation for camera extrinsic parameter estimation also has a weak point, which has different iteration number for approaching the minimal point according to the initial values and convergence time increases if the process run into a local minimum, In order to complement these shortfalls, we, first proposed constructing feature models using invariant vector of geometry, Secondly, we proposed a two-stage calculation method to improve accuracy and convergence by using 2D homography and LM method, In the experiment, we compared and analyzed the proposed method with existing method to demonstrate the superiority of the proposed algorithms.

  • PDF

Recursive Error-Component Correcting Method for 3D Shape Reconstruction (3차원 형상 복원을 위한 재귀적 오차 성분 보정 방법)

  • Koh, Sung-shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1923-1928
    • /
    • 2017
  • This paper is a study on error correction for three-dimensional shape reconstruction based on factorization method. The existing error correction method based on factorization has a limitation of correction because it is optimized globally. Thus in this paper, we propose our new method which can find and correct the only major error influence factor toward three-dimensional reconstructed shape instead of global approach. We define the error-influenced factor in two-dimensional re-projection deviation space and directly control the error components. In addition, it is possible to improve the error correcting performance by recursively applying the above process. This approach has an advantage under noise because it controls the major error components without depending on any geometric information. The performance evaluation of the proposed algorithm is verified by simulation with synthetic and real image sequence to demonstrate noise robustness.

Present Status and Prospect of LNG Strorage Tank (액화천연가스 저장탱크의 현황 및 전망)

  • 홍성호
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 1995
  • 1992년 9월 현재 전 세계적으로 운전 중(건설포함)인 액화 및 인수기지의 LNG 저장탱크는 지상식-이중벽 금속 탱크, 지상식-맴브레인 PC 탱크, 지상식-자립식 내부탱크/PC 외부탱크, 피드식-RC(Reinforced Concrete) 보강둑 탱크, 피트식-이중벽 금속탱크, 피트식-자립식 내부탱크/PC 외부탱크 및 지하식 탱크의 7가지 유형으로 나 타낼 수 있다. 또한 액화천연가스를 저장하는 내부탱크 소재에 따라 9%Ni강 및 MEMBRANE(SUS304) 형식으로 대별할 수 있다. MEMBRANE 저장탱크 형식의 핵심기술인 MEMBRANE은 -162.deg.C의 LNG에 의한 열수축팽창에 견딜 수 있도록 스테인레스강판 (SUS304)을 사용하여 기하학적으로 특이한 주름진 형상을 갖도록 설계되었으며 주름 형상에 따라 프랑스의 테크니가즈(Technigaz), 일본의 가와사끼(Kawasaki). 미쓰비시 (Mitsubishi), 이시가와지마하리마(Ishikawajima-Harima)사의 멤브레인과 세계에서 3번째로 한국가스공사 연구개발원이 개발한 링디식 멤브레인으로 구별할 수 있다. 본 해설에서는 국내의 전국 천연가스 공급사업계획 및 건설현황을 검토하고 최근 전 세계적으로 널리 사용되고 있는 액화천연가스 저장탱크의 종류를 용량별, 년도별로 분석하여 전세계의 액화천연가스 저장탱크에 관해 소개 하겠다.

  • PDF