• Title/Summary/Keyword: 기포크기

Search Result 202, Processing Time 0.037 seconds

An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System (DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향)

  • Park, S.C.;Oh, H.Y.;Chung, M.K.;Song, S.L.;Ahn, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.929-936
    • /
    • 2013
  • The saturator and injection nozzle are important facilities on the dissolved air flotation process. To increase the formation of micro bubble, it is required to improve the air dissolving performance in the saturator and keep the pressure uniform from the saturator to the nozzle. This study aimed to evaluate the performance of the saturator and the hydraulic effect of the nozzle and the pipe structure. The air volume concentration, bubble size and bubble residual time were measured in the test. The saturator, which had mounted with the spray nozzle, showed a good performance for bubble formation. Also, the characteristics of micro bubble formation were influenced by pressure uniformity and flow velocity through the orifice in the nozzle.

Detection of Void Defects in Ball Grid Array X-ray Image Using a New Blob Filter (볼 그리드 배열 기판의 X-ray 영상에서의 새로운 덩어리 검출 필터를 이용한 기포 형태 결함 검출 방법)

  • Peng, Shao-Hu;Lee, Hye-Jung;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2005-2006
    • /
    • 2011
  • Due to the advantages of small sizes, more I/O ports, etc., Ball Grid Array (BGA) has been used in the production of printed circuit board (PCB). However, BGA voids can degrade the performance of the board and cause failure. To automatically detect the voids in X-ray image, a novel blob filter that makes use of the local image gradient magnitude is proposed in this paper. The utilization of the local image gradient magnitude makes the proposed filter invariant to the image brightness, void shape, void position, and component interference. Furthermore, different sizes of box filters are employed to analyze the image in multi-scale, and as a result, the proposed blob filter is robust to void size. Experimental results show that the proposed method can obtain void detection accuracy up to 96.104% while keep low false ratio.

  • PDF

Gas hold-up variation with pore size of tray in trayed bubble column (Trayed bubble column 반응기에서 tray의 기공크기에 따른 gas hold-up 변화 연구)

  • Yang, Jung Hoon;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Lee, Ho-Tae;Jung, Heon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.133.1-133.1
    • /
    • 2010
  • 슬러리 기포탑 반응기는 열 및 물질 전달의 용이성, 낮은 운전비용 및 장치의 간단성의 장점을 가지고 있어서 Fischer-Tropsch 반응, bio-reaction 등에 많이 응용되고 있다. 그러나 기포탑 반응기 내의 물질 거동은 매우 복잡하기 때문에 많은 연구가 이루어지고 있음에도 불구하고 그 현상에 대한 명확한 이해는 어려운 상황이다. 특히 기포탑반응기 내에 기체의 포집율(gas hold-up)을 증가시키는 것을 목적으로 하는 연구들이 활발히 진행되고 있다. 본 연구에서는 trayed bubble column 반응기에서 tray의 기공크기에 따른 기체 포집율의 변화를 관찰하였다. 실험에 사용된 반응기는 내경이 0.15 m이고 높이 2.0 m의 아크릴 반응기를 이용하였다. 사용된 연속상은 수돗물을 사용하였고 분산상 기체로는 압축공기를 이용하였다. Tray의 기공크기는 1.1 mm부터 14.0 mm까지 변화시키면서 높이별 기체 포집율의 변화를 관찰하였다. 기체 포집율의 변화를 균일흐름 영역과 불균일 흐름 영역에서 그 양상이 다르게 나타났다. 즉 균일계 영역에서는 기공의 크기가 1.1 mm부터 2.9 mm까지 증가시면 기체포집율이 감소하는 반면 2.9 mm 이상에서는 증가하는 것으로 관찰되었다. 반면 불균일 흐름 영역에서는 전반적으로 기공의 크기가 작아질수록 기체포집율이 증가하였다. 또한 각각의 흐흠 영역에서의 기체포집율 증가정도는 확연한 차이를 보이는 것을 알 수 있었다. 이것은 흐름영역의 유체거동에 따라서 기포와 tray 기공사이의 상호작용 메커니즘이 달라지기 때문인 것으로 보인다.

  • PDF

Characteristics of Bubble Flow Behavior in a Gas-liquid Countercurrent Bubble Column Bioreactor (기-액 향류 흐름 기포탑 생물 반응기에서 기포 흐름 거동 특성)

  • Son, Sung-Mo;Kang, Suk-Hwan;Lee, Chan-Gi;Jung, Sung-Hyun;Kang, Yong;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.272-277
    • /
    • 2005
  • Characteristics of bubbling behavior and bubble properties were investigated in a gas-liquid countercurrent bubble column of in diameter 0.152 m and 3.5 m in height, respectively. Effects of gas and liquid velocities and bubble distribution mode(even, wall-side, central or asymmetric distribution) on the bubble properties such as chord length, frequency, rising velocity and holdup in the reactor were measured and examined by means of dual resistivity probe method. The bubble size, frequency and holdup increased with increasing gas($U_G$) or liquid velocity($U_L$). The rising velocity of bubbles increased with increasing $U_G$, whereas decreased with increasing $U_L$. The uniformity of bubble size distribution and bubble holdup decreased when the distribution mode of bubbles at the gas distributor was changed from even to wall-side, central or asymmetric. The central distribution of bubbles was better than asymmetric mode but worse than wall-side distribution, in considering the bubble holdup and uniformity of distribution.

A Study on the Behavior of Bubbles in Fluidized Bed (유동층내의 기포거동에 대한 연구)

  • 김용섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.24-28
    • /
    • 1994
  • In the present paper, the behavior of bubbles in a fluidized bed has been investigated experimentally. The bubble size, distribution of bubble, bubble rising velocity and pressure fluctuation in the fluidized bed are obtained at different air velocity. The results are discussed and compared study the effect of air velocity on the behavior of a bubbles in fluidized bed.

  • PDF

Fractional gas hold-up in trayed bubble column (Trayed 기포탑 반응기에서 높이에 따른 기포입자의 거동분석)

  • Yang, Jung Hoon;Hur, Young Gul;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Kim, Byung Kwon;Lee, Ho-Tae;Jung, Heon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.77.1-77.1
    • /
    • 2011
  • 슬러리 기포탑 반응기는 열 및 물질 전달의 용이성, 낮은 운전비용 및 장치의 간단성의 장점을 가지고 있어서 Fischer-Tropsch 반응, bio-reaction 등에 많이 응용되고 있다. 특히, 반응물은 기체 상태로 반응기에 투입이 되는데, 이 기포입자의 상승하는 힘을 바탕으로 기상/액상/고상이 균일하게 혼합되게 된다. 많은 연구자들이 이러한 기포탑 반응기의 성능을 개선하고자, 다양한 반응기 디자인에 대하여 보고하고 있다. 특히 반응기 내부에 tray를 설치함으로써, 기포 포집율을 증진시기고 액상의 역류를 최소화시키는 연구가 활발히 진행되고 있다. 본 연구에서는, 다양한 기공크기를 갖는 tray를 활용함으로써 높이에 따른 기포 포집율의 변화 및 반응기 내에 기포 입자의 거동 특성에 대하여 살펴보았다.

  • PDF

Utilization of Image Analysis Technique for Characterization of Micro-Bubbles Generated by Polymeric Membrane Module (고분자 중공사막 모듈을 이용한 미세기포 발생과 이미지 분석기법을 이용한 기포 특성 파악)

  • Kim, Jun-Young;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.447-452
    • /
    • 2011
  • In this study, the polymeric membrane module is used as a diffuser and an image analysis technique based on visual information is applied to get bubble characteristics. The bubble size generated passed through polymeric membrane module was smaller from 30 to 64% than that of air stone, and bubble volume over 70% was ranged from 0.2 to 0.82 mm. But over 80% the bubbles from air stone diffuser ranged from 0.77 to 1.08 mm. The air stone and polymeric membrane module used as diffuser for a flotation system. The floc size inside the flotation reactor using air stone diffuser was bigger than that of the polymeric membrane module, which means that the micro-bubbles generated from polymeric membrane module could provide better opportunities for collisions between colloidal particles than those from air stone diffuser. Therefore, there is a possibility to apply the polymeric membrane module as a diffuser to increase the removal efficiency in the flotation process. Also, the image analysis technique used in this study could be applied as a useful analytical tool for acquisition of an information about the bubble characteristic.

Oxidation of Phenol Using Ozone-containing Microbubbles Formed by Electrostatic Spray (전기장에 의해 생성된 미세기포를 이용한 페놀의 오존산화)

  • Shin, Won-Tae;Jung, Yoo-Jin;Sung, Nak-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1292-1297
    • /
    • 2005
  • The use of ozone in water and wastewater treatment systems has been known to be a process that is limited by mass transfer. The most effective way to overcome this limitation is to increase the interfacial area available for mass transfer by decreasing the size of the ozone gas bubbles that are dispersed in solution. Electrostatic spraying(ES) of ozone into water was investigated in this work as a method of increasing the rate of mass transfer of ozone into a solution and thereby increasing the rate of phenol oxidation. Results were obtained for ES at input power levels ranging from 0 to 4 kV and compared with two different pore-size bubble diffusers($10{\sim}15{\mu}m$ and $40{\sim}60{\mu}m$). It was determined that the rate of mass transfer could be increased by as much as 40% when the applied voltage was increased from 0 to 4 kV as a result of the smaller bubbles generated by ES. In addition, ES was shown to be more effective than the medium-pore-size($10{\sim}15{\mu}m$) bubble diffuser and the best results were achieved at low gas flow rates.

Influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva (인공타액에 노출되었던 금속도재관의 재소성이 색조와 표면기포 형성에 미치는 영향에 관한 연구)

  • Park, Ji-Hyun;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.161-167
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva. Materials and methods: Thirty disk-shaped specimens were made in 10 mm diameter with 0.5 mm metal core thickness and 1 mm ceramic thickness. A spectroradiometer was used to determine the CIE Lab coordinates. The number and size of surface bubble were observed with a stereomicroscope. After the exposure to artificial saliva for 7 days, re-firing was performed at glazing temperature. After re-firing, the CIE Lab were calculated, and the number and size of surface bubble were observed again. The change in shade was expressed with ${\Delta}E$. Statistical analysis was done with paired t-test for the change in the number of surface bubble and student t-test for the change in the size of surface bubble (${\alpha$}=0.05). Results: Shade difference was calculated 2.14 ${\Delta}E$ units. The mean number of surface bubble was $1.33{\pm}1.49$ before re-firing, $3.27{\pm}2.90$ after re-firing. After re-firing, the number of surface bubble was significantly increased (P<.05). The mean size of surface bubble was $81.97{\pm}32.03\;{\mu}m$ before re-firing, $142.94{\pm}47.40\;{\mu}m$ after re-firing. After re-firing, the size of surface bubble was significantly increased (P<.05). Conclusion: Shade change after re-firing was perceptible (${\Delta}E$ < 2.0) and clinically acceptable (${\Delta}E$ < 3.7). The number and size of surface bubble was significantly increased after re-firing. Further investigation to decrease the surface bubble on the extra oral repair of metal-ceramic crown, will be needed in future study.

An Experimental Study on Properties of Foam According to Concentration of Vegetable and Mixed Foaming Agent and Properties of Foamed Concrete According to Replacing Ratio of Foaming Agent (식물성 및 혼합 기포제의 농도에 따른 기포 특성과 혼입량에 따른 기포 콘크리트의 물성에 관한 실험적 연구)

  • Jeong, Seong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.22-23
    • /
    • 2016
  • This study analyzes the properties of foam according to the concentration of vegetable foaming agent that is used in traditional and mixed foaming agent of developing stage, and confirms how the foams influence foamed concrete by searching for properties of foamed concrete according to replacing ratio of vegetable foaming agent and mixed foaming agent. This is for the purpose of providing basic data for the use of foamed concrete through improvement on the problem such as unstability, falling in fluidity and the strength of existed foaming agent.

  • PDF