An Experimental Study on the Temperature and Thermal Stresses in Massive Footing and Column (현장조건을 고려한 콘크리트 기초 및 교각구조의 온도 및 열응력에 관한 실험적 연구)

  • 오병환;백신원;엄주용;임동환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.233-237
    • /
    • 1994
  • 매스콘크리트에서는 수화열에 의하여 유발된 높은 온도가 열응력을 일으키는 원인이 되며 구속의 정도에 따라 인장응력이 발생되어 균열이 발생하게 된다. 따라서, 매스콘크리트 타설시 시멘트의 수화열에 의한 균열이 심각한 문제가 된다. 본 연구에서는 매스콘크리트 기초 및 교각구조에 대한 수화열 실험을 통해 온도분포 및 변형분포를 측정하고 이에 대한 온도 및 열응력 해석을 통해 매스콘크리트에 대한 수화열 특성을 규명하였다.

  • PDF

Development of Temperature Control Technology for Massive Machine Foundations (기계기초 매스콘크리트의 균열제어를 위한 온도관리기법의 개발)

  • Huh, Taik-Nyung;Son, Young-Hyun;Lee, Suck-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.227-233
    • /
    • 2001
  • 최근 비약적인 경제발전에 힘입어 장대교량, 항만, 댐, 도로, 원자력 발전소 등과 같은 대규모 기간구조물의 건설이 증가하고 있으며, 구조물은 대형화 혹은 고강도화되는 추세에 있다. 특히, 전술한 구조물을 매스콘크리트로 가설하게 되면 초기재령시에 수화열로 인한 균열이 발생할 가능성이 매우 높기 때문에 효율적인 매스콘크리트의 개발과 매스콘크리트 구조물의 설계기술 및 시공방법이 중요한 연구대상으로 등장하게 된다. 본 논문에서는 가로 52.6m, 세로 14.4m, 높이 8.5m의 기계기초 매스콘크리트의 시공에 적합한 온도관리기법을 다음과 같은 단계로 제안하고자 한다. 먼저 온도상승요인을 최소화하는 콘크리트의 배합비를 산정한다. 산정된 콘크리트의 열특성을 측정하기 위해 단열온도실험을 수행하여 각종 열특성상수와 단열온도 상승곡선식을 도출한다. 이와 같은 열특성치를 콘크리트 구조체에 적용하여 열응력해석을 수행한다. 이와 같은 열응력해석을 통하여 구조물의 분할타설높이에 따라 온도균열이 발생하지 않는 콘크리트 내외부의 온도차를 결정한다. 이때 열응력해석에 범용 유한요소 프로그램인 Diana을 사용한다. 콘크리트의 타설은 현장조건과 타설시점을 최대로 고려하고 양생방법으로 콘크리트 내외부의 온도차를 최소화하기 위해 이중단열효과가 있는 거푸집과 가열장비을 사용한다. 또한 콘크리트의 온도관리를 위하여 구조물 내외부에 온도게이지를 매립하고 30분마다 계측을 수행하면서 콘크리트 내외부 온도차가 허용 해석범위를 유지하도록 한다. 양생기간은 7-10일 정도를 유지한다. 전술한 온도관리기법을 통하여 완공후 수평정밀도가 기초의 허용침하량으로 환산하여 $1{\mu}m$ 인 고정밀도의 기계기초는 완벽하게 시공되었다. 따라서 매스콘크리트의 온도균열을 제어할 수 있는 시공방법으로 제안한다. 또한 매스콘크리트의 내외부 온도차를 단열온도실험과 온도해석으로부터 정한 값이내로 제어하고 충분한 양생관리를 병행하면 수화열에 의한 콘크리트의 온도균열을 최소화할 수 있을 것으로 기대한다.

  • PDF

A Method on the Control of Hydration Heat of Mass Concrete Considering Difference of Setting Time (응결 시간차를 활용한 매스 콘크리트의 수화열 조정 공법)

  • 심보길;윤치환;오선교;최주석;한천구
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.49-52
    • /
    • 2002
  • 종전의 경우 건축물의 기초 구조는 직접 기초 및 말뚝 기초 등이 많이 활용되었으나 최근에는 말뚝 기초의 경우 소음, 진동 등의 환경 문제가 중요시됨에 따라 대부분 매트 기초로 시공하는 경우가 많아졌다. 따라서, 기초 부분의 매트 콘크리트 시공은 환경 문제를 해결하고 건물의 하부구조를 안전하게 지탱하게 하는 역할은 만족되었지만. 두께가 80cm를 넘어 매스 콘크리트로 되는 경우가 많아 수화열에 의한 균열 문제 등은 콘크리트의 품질 확보에 있어 새롭게 해결해야만 하는 중요한 과제로 등장하고 있다.(중략)

A Study on the Thermal Crack Control of Foundation for Large Turbine (대형 터빈 기초 구조물의 온도균열 제어에 관한 연구)

  • Ha, Ju-Hyung;Cho, Yun-Gu;Lee, Kewn-Chu;Lim, Chang-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.287-297
    • /
    • 2014
  • Heat of hydration of mass concrete is one of the most important factors that significantly affect structural quality and construction period. Therefore, appropriate methods to control heat of hydration are essential technologies for mass concrete construction. In this study, probability of thermal cracking was checked by thermal analysis prior to the construction of a turbine foundation in a domestic power plant. Subsequently, changes of concrete mix proportion and an effective curing method were proposed to control heat of hydration of mass concrete structures. Concrete manufactured by slag cement was proposed instead of concrete produced by ordinary Portland cement, and an automated curing method was proposed to improve the curing method using typical moist curing with blanket. The automated curing method maintains the temperature difference between center and surface of concrete below a setting value by temperature monitoring. Concrete with slag cement was used for actual construction. One of two identical turbine foundations was cured by an insulated curing method, and the other was cured by the automated curing method to compare the curing methods. And then, the effects of control of heat of hydration were evaluated based on temperature/strain monitoring and crack investigations.

An Experimental Study on Properties of Concrete Using Latent Heat Binder (잠열성 결합재를 활용한 콘크리트의 특성에 관한 실험적 연구)

  • Kim, Yong-Ro;Kim, Do-Su;Khil, Bae-Su;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.661-668
    • /
    • 2008
  • It is necessary to develop a new technology for effectively reducing hydration heat and controlling thermal cracking caused increasing construction of large size massive concrete structures such as mat foundation of high-rise building, grandiose bridge, and LNG tank. Therefor, to develop a new technology for reducing hydration heat of large size massive concrete in this study, after developing the latent heat binder for controling hydration heat of concrete by application of latent heat material, it was investigated basic properties and durability such as slump, air content and compressive strength, shrinkage properties, permeability, freezing and thawing resistance, corrosion, and hydration heat generation properties of concrete using latent heat binder. As a test result, it was confirmed that latent heat binder was not affected adversely the basic property and durability of concrete, and was advanced on the reduction of hydration heat and control of thermal crack. It is expected to be applied as the excellent technology on the management of hydration heat and thermal crack in large size mass concrete structures.

A Study on the Basic Properties of Concrete and Characteristics of Blended Low Heat Cement (혼합형 저발열 시멘트의 특성과 콘크리트 기초 물성에 관한 연구)

  • 송용순;한정호;강석화;김상철
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.5
    • /
    • pp.177-187
    • /
    • 1998
  • 최근 국내에서 해양 구조물, 장대 교량의 하부구조물, LNG저장탱크 등 매스콘크리트의 증가추세에 따라 구조물의 고내구성과 관련하여 시멘트의수화열에 의한 온도균열의 발생을 최소화 시킬 수 있는 3성분계 혼합형 저발열시멘트가 개발되어 실 구조물의 적용단계에 있으나, 저발열시멘트가 개발되어 실 구조물의 적용단계에 있으나 저발열시멘트의 특성에 대한 전반적인 연구보고가 국내에서는 미진한 실정이다. 따라서 본 연구에서는 3성분계 혼합형 저발열시멘트의 특성 및 코\ulcorner리트의기초물성을 1종 보통포틀랜트 시멘트, 5종 내황산염시멘트, 슬래그시멘트와 비교하였다. 글 결과 저발열 콘크리트의 찹축강도는 초기재령에서 강도발현률이 적은 반면 장기강도발현률은 상당히 큰 경향을 보였다. 또한 수화열은 1종시멘트를 사용한 콘크리트에 비하여 1/3~1/2정도로 매스콘크리트의 수화열을 대폭적으로 저감시킬 수 있을 뿐만 아니라 염소이온에 대한 저항성이 상대적으로 높게 나타나 거대 해양 구조물의 적용에 매우 유리한 시멘트로 판단되었다.