• Title/Summary/Keyword: 기초의학

Search Result 657, Processing Time 0.027 seconds

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Evaluation of Image Quality in Micro-CT System Using Constrained Total Variation (TV) Minimization (Micro-CT 시스템에서 제한된 조건의 Total Variation (TV) Minimization을 이용한 영상화질 평가)

  • Jo, Byung-Du;Choi, Jong-Hwa;Kim, Yun-Hwan;Lee, Kyung-Ho;Kim, Dae-Hong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.252-260
    • /
    • 2012
  • The reduction of radiation dose from x-ray is a main concern in computed tomography (CT) imaging due to the side-effect of the dose on human body. Recently, the various methods for dose reduction have been studied in CT and one of the method is a iterative reconstruction based on total variation (TV) minimization at few-views data. In this paper, we evaluated the image quality between total variation (TV) minimization algorithm and Feldkam-Davis-kress (FDK) algorithm in micro computed tomography (CT). To evaluate the effect of TV minimization algorithm, we produced a cylindrical phantom including contrast media, water, air inserts. We can acquire maximum 400 projection views per rotation of the x-ray tube and detector. 20, 50, 90, 180 projection data were chosen for evaluating the level of image restoration by TV minimization. The phantom and mouse image reconstructed with FDK algorithm at 400 projection data used as a reference image for comparing with TV minimization and FDK algorithm at few-views. Contrast-to-noise ratio (CNR), Universal quality index (UQI) were used as a image evaluation metric. When projection data are not insufficient, our results show that the image quality of reconstructed with TV minimization is similar to reconstructed image with FDK at 400 view. In the cylindrical phantom study, the CNR of TV image was 5.86, FDK image was 5.65 and FDK-reference was 5.98 at 90-views. The CNR of TV image 0.21 higher than FDK image CNR at 90-views. UQI of TV image was 0.99 and FDK image was 0.81 at 90-views. where, the number of projection is 90, the UQI of TV image 0.18 higher than FDK image at 90-views. In the mouse study UQI of TV image was 0.91, FDK was 0.83 at 90-views. the UQI of TV image 0.08 higher than FDK image at 90-views. In cylindrical phantom image and mouse image study, TV minimization algorithm shows the best performance in artifact reduction and preserving edges at few view data. Therefore, TV minimization can potentially be expected to reduce patient dose in clinics.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Morphometric Analysis of Distances between Sacral Hiatus and Conus Medullaris Using Magnetic Resonance Image in Korean Adult (자기공명영상을 이용한 한국 성인의 엉치뼈틈새와 척수원뿔 사이 거리 연구)

  • Park, Tai Soo;Hwang, Byeong-Wook;Park, Sang-Joon;Baek, Sun-Yong;Yoon, Sik
    • Anatomy & Biological Anthropology
    • /
    • v.29 no.4
    • /
    • pp.145-154
    • /
    • 2016
  • The purpose of this study was to provide basic biometric data on Korean adults through magnetic resonance imaging (MRI)-based measurements of the distances between the apex of sacral hiatus (SH) and the termination of dural sac (DS), and between SH and conus medullaris (CM) because they are critical to the performance of epidural neuroplasty. A total of 200 patients(88 males and 112 females) with back pain, who had no spine fracture, significant spinal deformity, and spondyloisthesis were selected for this study. The subjects were of mean age 54.3 (20~84) years and mean height 161.3 cm (135~187). T2-weighted MRI images were used for correlation analysis to evaluate the relationships between the distances, and variables such as sex and height. In all patients, the mean distance between SH and DS was $62.8{\pm}9.4mm$ and the mean distance between SH and CM was $232.2{\pm}21.8mm$. The minimum distance and the maximum distance between SH and DS were 34.8 mm and 93.9 mm respectively, and the minimum distance and the maximum distance between SH and CM were 155.0 mm and 284.0 mm respectively. In female patients, both the distances between the SH and DS, and between SH and CM were shorter when compared to those of the male patients(p<0.05). Both the distances between SH and DS and between SH and CM showed a significant correlation with height(p<0.01). The results of this study will provide a useful biometric data on the distances between SH and DS and between SH and CM in Korean in ensuring clinical safety and in the development of more effective catheterization techniques for epidural neuroplasty in Korean.

Effects of Straight Body Exercise Therapy on Neck Pain, Necks Disability Index and Neck Length Among Turtle Neck Syndrome Patient (정체 운동이 거북목 증후군의 경부통증과 경추 기능장애지수 및 목 길이에 미치는 효과)

  • Kim, Seung Won;Kwak, Jong Hyeok;Kim, Gyeong Rip;Choi, Min Gyeong;Sung, Hyun Chul;Song, Geun Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.201-210
    • /
    • 2021
  • This study was conducted not only to find out the effect of straight body exercise on neck pain, necks disability and neck length change of turtle neck syndrome patients but also to provide fundamental data for this field in the future. Number of 60 persons were selected by pre-test and divided to 21 persons in straight body exercise group, 19 persons in exercise group and 20 persons in control group(non-exercise group). 5 kinds of straight body exercise were applied in straight body exercise group, 8 kinds of strengthening cervical vertebral exercise were applied in exercise group and no exercise was applied in control group. Neck pain, necks disability index and neck length were measured before and after exercise and 10 weeks later as well. The data were analyzed by SPSS(v18.0). In straight body exercise group and exercise group, neck length, neck pain and necks disability index were significantly decreased after eight weeks of exercise and there was no significant difference in control group. Neck length which was checked every week in straight body exercise group and exercise group was significantly decreased and there were significant differences after 3 weeks.. After 2 weeks of 8 weeks exercise, neck length, neck pain and necks disability were checked again in post test and those results were maintained just like 8 weeks exercise status. As above results, it was more efficient in the straight body exercise group than exercise group and control group to decrease neck pain, necks disability and neck length of turtle neck syndrome patients. Furthermore, after 2 weeks of 8 weeks exercise, the results were maintained just like 8 weeks exercise status. Therefore, the author consider that straight body exercise will be effective exercise for turtle neck syndrome patients, and this study would provide fundamental data for this field in the future.

Health Status and Use of Health Care Services of the Elderly Utilizing Senior citizen Centers (경로당 노인의 건강상태와 건강관리서비스 이용 관련요인 분석)

  • Shin, Sun-Hye;Kim, Jin-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.27 no.1
    • /
    • pp.99-113
    • /
    • 2002
  • For this study a sample of 205 people, 66 males and 139 females, over 65 years of age, residing in C-gu of S-si and utilizing senior centers, were selected, The objective of the study was to provide basic data for health promotion program development provided by health centers. A questionnaire was used to collect date on general characteristics, health status, social health status and utilization rate for health services. The instruments used in this study were the Lawton scale, to measure daily routine function, the MMSE-K developed by Folstein and modified to fit the Korea situation, for mental health status, and the CES-Dtool developed by Radloff, for emotional health status. the SPSS Window program was used to calculate percentages. Tests of significance were done using t-test and ANOVA. Multiple regression analysis was used to identify variables influencing the use of health services. The results are as follows : Of those utilizing senior citizen centers, 40.9% of males and 17.3% of the female thought they were healthy. The average score for IADL was 7.4. The daily routine of female respondents consisted of buying household articles and drugs, and other IADLs such as riding the bus or subway alone. These resulted in a higher score compared to males. For emotional health, 7.6% of the males reported depression compared to 21.6% of the females. For mental health, 48.5% of the males and 28.8% of the females were found to be in the group suspicious for dementia. On social health, 57.6% of the males and 62.6% of the females reported no intimate human relations. Of those older people who had close human relations, 52.5% of the males indicated a friend as the closest person and 53.8% of the females, their children. On use of health services, there was a significantly higher need for mobile medical care services treatment for those with lower education levels and status of window/widower. There was a significantly higher need for health exmination services for those with lower levels of exercise, greater satisfaction with sleep, higher levels of oral health care, and higher social contacts. In conclusion, there is a need to provide varied programs for the promotion of health, along with parallel resolution of social, psychological and economic issues. It is recommended that health services for elderly people provided by the health centers be implemented with full recognition of these characteristics and differences.

  • PDF

Evaluation on the Immunization Module of Non-chart System in Private Clinic for Development of Internet Information System of National Immunization Programme m Korea (국가 예방접종 인터넷정보시스템 개발을 위한 의원정보시스템의 예방접종 모듈 평가연구)

  • Lee, Moo-Sik;Lee, Kun-Sei;Lee, Seok-Gu;Shin, Eui-Chul;Kim, Keon-Yeop;Na, Bak-Ju;Hong, Jee-Young;Kim, Yun-Jeong;Park, Sook-Kyung;Kim, Bo-Kyung;Kwon, Yun-Hyung;Kim, Young-Taek
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.65-75
    • /
    • 2004
  • Objectives: Immunizations have been one of the most effective measures preventing from infectious diseases. It is quite important national infectious disease prevention policy to keep the immunizations rate high and monitor the immunizations rate continuously. To do this, Korean CDC introduced the National Immunization Registry Program(NIRP) which has been implementing since 2000 at the Public Health Centers(PHC). The National Immunization Registry Program will be near completed after sharing, connecting and transfering vaccination data between public and private sector. The aims of this study was to evaluate the immunization module of non-chart system in private clinic with health information system of public health center(made by POSDATA Co., LTD) and immunization registry program(made by BIT Computer Co., LTD). Methods: The analysis and survey were done by specialists in medical, health field, and health information fields from 2001. November to 2002. January. We made the analysis and recommendation about the immunization module of non-chart system in private clinic. Results and Conclusions: To make improvement on immunization module, the system will be revised on various function like receipt and registration, preliminary medical examination, reference and inquiry, registration of vaccine, print-out various sheet, function of transfer vaccination data, issue function of vaccination certification, function of reminder and recall, function of statistical calculation, and management of vaccine stock. There are needs of an accurate assessment of current immunization module on each private non-chart system. And further studies will be necessary to make it an accurate system under changing health policy related national immunization program. We hope that the result of this study may contribute to establish the National Immunization Registry Program.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Trends of Study and Classification of Reference on Occupational Health Management in Korea after Liberation (해방 이후 우리나라 산업보건관리에 관한 문헌분류 및 연구동향)

  • Ha, Eun-Hee;Park, Hye-Sook;Kim, Young-Bok;Song, Hyun-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.809-844
    • /
    • 1995
  • The purposes of this study are to define the scope of occupational health management and to classify occupational management by review of related journals from 1945 to 1994 in Korea. The steps of this study were as follows: (1) Search of secondary reference; (2) Collection and review of primary reference; (3) Survey; and (4) Analysis and discussion. The results were as follows ; 1. Most of the respondents majored in occupational health(71.6%), and were working in university (68.3%), males and over the age 40. Seventy percent of the respondents agreed with the idea that classification of occupational health management is necessary, and 10% disagreed. 2. After integration of the idea of respondents, we reclassified the scope of occupational health management. It was defined 3 parts, that is , occupational health system, occupational health service and others (such as assessment, epidemiology, cost-effectiveness analysis and so on). 3. The number of journals on occupational health management was 510. It was sightly increased from 1986 and abruptly increased after 1991. The kinds of journals related to occupational health management were The Korean Journal of Occupational Medicine(18.2%), Several Kinds of Medical Colloge Journal(17.0%), The Korean Journal Occupational Health(15.1%), The Korean Journal of Preventive Medicine(15.1%) and others(34.6%). As for the contents, the number of journals on occupational health management systems was 33(6.5%) and occupational health services 477(93.5%). Of the journals on occupational health management systems, the number of journals on the occupational health resource system was 15(45.5%), occupational finance system 8(24.2%), occupational health management system 6(18.2%), occupational organization 3(9.1%) and occupational health delivery system 1 (3.0%). Of the journals on occupational health services, the number of journals on disease management was 269(57.2%), health management 116(24.7%), working environmental management 85(18.1%). As for the subjects, the number of journals on general workers was 185(71.1%), followed by women worker, white coiler workers and so on. 4. Respondents made occupational health service(such as health management, working environmental management and health education) the first priority of occupational health management. Tied for the second are quality analysis(such as education, training and job contents of occupational health manager) and occupational health systems(such as the recommendation of systems of occupational and general disease and occupational health organization). 5. Thirty seven respondents suggested 48 ideas about the future research of occupational health management. The results were as follows: (1) Study of occupational health service 40.5%; (2) Study of organization system 27.1%; (3) Study of occupational health system (e.g. information network) 8.3%; (4) Study of working condition 6.2%; and (5) Study of occupational health service analysis 4.2%.

  • PDF