• Title/Summary/Keyword: 기초연결부

Search Result 176, Processing Time 0.035 seconds

An Experimental Study For Improvement of Joint Detail of Steel Pier - Foundation (강재교각 기초부의 연결상세 개선을 위한 실험적 연구)

  • Kim, Hee-Ju;Ham, Jun-Su;Yang, Sung-Don;Hwang, Won-Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.491-501
    • /
    • 2012
  • Generally, a steel pier-foundation has been designed and constructed with a anchor frame. However, because of the complicated design and construction, the foundation's size has become large and has been overdesigned. In this study, three specimens were made and the tests were conducted to suggest a new shape in regard to the pier-foundation's joint details using the high performance steel. One of the specimens was made up of the general anchors and the anchor frame. Another specimen consisted of the high tension anchors and the studs, and the other specimen was composed of the high tension anchors and the inner steels. After the performance of each specimen was compared and analyzed, the behavior characteristics according to the joint were analyzed.

Seismic Performance of Column-Footing Connection of Modular Pier using CFT (CFT를 이용한 모듈러 교각 기둥-기초 연결부의 내진성능)

  • Kim, Ji Young;Kim, Ki Doo;Ma, Hyang Wook;Chung, Chul-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.73-85
    • /
    • 2014
  • The CFT (Concrete Filled steel Tubes) column-footing connection is cast-in-place embedded type which provides simple construction procedure, low cost, and superior structural performance. In this study, CFT column-footing connection of modular pier is proposed and structural performance is evaluated by experimental tests. To evaluate structural performance of the CFT column-footing connection, a series of experimental tests were performed for the 4 specimens with different embedded depth. As a result of the quasi-static test, the specimen with 0.6D (0.6 times the outside diameter of steel tube) embedded depth showed relatively low ductility than other specimens with larger embedded depth due to cone failure of base concrete occurred during the lower loading step. On the contrary, cone failure of the base concrete was not observed in the specimens with larger embedded depth than 0.9D, but typical flexural failure in lower part of CFT column was observed. With the analyses of force-displacement curve, displacement ductility, and energy dissipation capacity, it is concluded that the rational range of embedded depth of the CFT column-footing connection is from 0.9D to 1.2D in view of good seismic performance.

An Analytical Study on the Strength Behavior of Column-Foundation Connection with High Tension Bolts (고장력 볼트 기둥-기초 연결부의 강도특성에 관한 해석적 연구)

  • Hwang, Dong A;Hwang, Won Sup;Ham, Jun Su;Jeong, Jin Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.121-128
    • /
    • 2016
  • In order to suggest a reasonable design for the circular concrete filled tube steel column-foundation connection applying high-tension bolts, Overall structural behavior and characteristics according to various variables of column-foundation connection are numerically analyzed using a commercial FE analysis program, ABAQUS. To that goal, finite element analysis is conducted on the basis of the previous study replacing anchor bolts to high-tension bolts, and the analytical results are validated by comparison with experimental results. Also, the various variables(embedded depth and grade of anchor, and height and thickness of rib) involved in behavior of the column-foundation connection are selected through analyzing the current design criteria, and the characteristics of the column-foundation connection are compared and analyzed according to the various variables. In case of the anchor bolts, Applying the high-tension bolts is more advantage and securing the embedded depth beyond 0.5D is recommendable. In case of the rib, a minimum of 0.5D for rib's height and $0.4t_b$ for rib's thickness should be secured to develop the structural performance.

Finite Element Analysis for Transmission Tower Behavior Characteristic by Connection Beam Stiffness (수치해석을 이용한 송전철탑 연결형 기초의 연결보 강성에 따른 거동 특성)

  • Choi, YoungHo;Kyung, DooHyun;Lee, JunHwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.219-227
    • /
    • 2013
  • This study analyzed the effect of performance connected-type foundations of behavior and the connected beams according to the characteristics into soft clay transmission tower foundation. For this purpose, the finite element analysis model was built and connected to the transmission tower foundation mat and the contact area of the connection beam by the percentage change in the behavior and resistance characteristics were analyzed and finite element verification of the validity of the analytical model was conducted using connected-type transmission tower results of the model experiments constructed, and effective connected-type transmission tower basis of the behavior of connected beams were selected by analyzing the effect due to the increase of the stiffness. In addition, weak analysis by connected beam self-bending moment distribution was conducted.

The Study on Local Composite Behavior of Connection Member between Steel Pipe Pile and Concrete Footing (강관 말뚝 기초 두부 연결부의 합성거동에 대한 연구)

  • You, Sung-Kun;Park, Jong-Myen;Park, Dae-Yong;Kim, Young-Ho;Kang, Won-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.288-296
    • /
    • 2003
  • Generally, application of steel pipe pile as deep foundation member needs special requirement for the connection method between steel pipe pile and concrete footing. Even though two types of connection method are suggested in the related specification, type B-method is provident. To investigate real structural behavior of type B connection, several load tests are done with carefully designed experimental system. The purpose of this experiment is mainly focused on the understanding of actual behavior which can be predicted by design theory. At this research stage, vertical and lateral loading test are done for three types of specimen to review stress concentration, formation and behavior of imaginary RC column in the footing and effect of non-slip device installed in the steel pipe pile. The load resistance mechanism in these specific connection method is predicted based on both experimental results. The three-dimensional finite element modeling is also done for the purpose of comparison between numerical and experimental result. With all the results gained from experiment the structural behavior of imaginary RC column in the design concept is confirmed. The role of non-slip device is very important and it affects the resistance capacity with help of composite action of concrete and steel pipe pile.

Resistance Increasing Factor of Connected-pile Foundation for Transmission Tower in Clay (점토지반에 근입된 송전철탑 연결형 말뚝기초의 저항력증가계수)

  • Kyung, Doo-Hyun;Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.8
    • /
    • pp.31-41
    • /
    • 2012
  • Pile foundation for transmission tower constructed in weak ground can cause the damage of the tower due to the different settlement between the foundations. In Japan and USA, connected-pile foundations whose 4 foundations are connected each other by beams were used for transmission tower (TEPCO 1988, IEEE 2001). Resistance increasing factors for connected-pile foundation signify increasing amount of resistance due to the effect of connected-pile material. In this study, we performed model lateral load tests of connected-pile foundations for transmission tower and found the resistance increasing factors for connected-pile foundation. The tests were performed in silty clay, and the resistance increasing factors were founded in various conditions that lateral load directions and height, the stiffness of beams in the connected-pile foundations were changed. The resistance increasing factors from our research were presented as a function of normal lateral loading height and normal stiffness of the connected-pile material. The resistances which were estimated from the resistance increasing factors were similar to measured values.

Behaviors of Joints with Perfobond Rib Shear Connectors in Steel-PSC Hybrid System (Perfobond Rib을 적용한 강-PSC 혼합구조 연결부의 거동 평가)

  • Kim, Sang Hyo;Lee, Chan Goo;Yoon, Ji Hyun;Won, Jeong Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.647-657
    • /
    • 2009
  • This paper studies the behavior of joints in steel-PSC (prestressed concrete) hybrid beams, which is necessary for the application of hybrid beams to spliced girder bridges, and proposes a new type of joint with improved construction convenience and structural behavior. In the proposed joint, perfobond rib shear connectors are attached to the upper and lower plates, which are expanded from the steel girders and located between the steel girder and the PSC girder. The experimental tests were performed on hybrid beams with the suggested joint. The results showed that all the beams had similar ultimate strengths and failure modes, due to the failure of their PSC parts. The composite action of the perfobond ribs was verified by examining the initial stiffness and cracks of the test beams. In addition, the test beams showed a higher degree of ultimate strength than the beams with stud shear connectors in the joints that had been previously studied. Thus, the proposed joint is effective for the steel-PSC hybrid beam.

The Influence of Negative Skin Friction on Piles in Groups Connected to a Cap (부마찰력이 작용하는 기초판으로 연결된 군말뚝의 거동)

  • Lee, Cheol-Ju;Park, Byung-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.25-31
    • /
    • 2006
  • Over the years the investigation of behaviour of piles in groups connected to a cap in consolidating soil has attracted far less attention than the study of isolated piles in groups. In this paper, a series of three-dimensional numerical simulations have been performed to study the behaviour of pile groups connected to a cap in consolidating ground. Both elastic no-slip and elasto-plastic slip analyses were considered. Based on the analysis results, when piles were connected to a cap, tensile forces were developed near the pile head at the outer piles. Elastic solution and no-slip analysis over-predicted the tensile force near the pile head for outer piles. Relatively speaking, the number of piles in a group is more important than the pile spacing in terms of the influence of negative skin friction on the pile behaviour. The issue on the development of tensile forces on the pile head at the outer piles is perhaps needed to be carefully considered in the pile design to prevent the damages of the pile-cap connection.

A Study on Characteristics of Traffic Flow in Congested Traffic at On-Ramp Influence Area (혼잡교통류 상태에서의 연결로 합류부 교통류 특성에 관한 기초 연구)

  • Kim, Sang-Gu;Kim, Young-Ho;Kim, Tae-Wan;Son, Young-Tae
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.5
    • /
    • pp.99-109
    • /
    • 2004
  • Most traffic congestion on a freeway occurs in the merge area, where conflicts between mainline traffic and on-ramp traffic are frequently generated. So far, research on the merge area has mainly dealt with free flow traffic and research on the congested traffic at the merge area is rare. This study investigates the relationships between mainline traffic and on-ramp traffic at three different segments of the merge area. For this purpose, new indicators based on such traffic variables as flow, speed, and density are used. The results show that a negative relationship exists between mainline and on-ramp flow. It is also found that the speed and the density of the right two lanes in the mainline traffic are significantly affected by the on-ramp flow. Based on the correlation analysis of the indicators, it is confirmed that the ramp influence area is the right two lanes of the freeway mainline. The revealed relationships between mainline and on-ramp traffic may help to analyze the capacity of the downstream freeway segment of the merging area in congested traffic. The findings of this studyalso provide a basis to develop a model that estimates the merge traffic volume in congested traffic, which is neither theoretically nor empirically sound in most other traffic flow models developed so far.

Pile-cap Connection Behavior Dependent on the Connecting Method between PHC pile and Footing (PHC말뚝과 확대기초 연결방법에 따른 접합부 거동)

  • Bang, Jin-Wook;Oh, Sang-Jin;Lee, Seung-Soo;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.25-32
    • /
    • 2016
  • The pile-cap connection part which transfers foundation loads through pile body is critical element regarding flexural and shear force because the change of area, stress, and stiffness occurs in the this region suddenly. The purpose of this study is to investigate the structural behavior of pile-cap connection dependent on fabrication methods using conventional PHC pile and composite PHC pile. A series of test under cyclic lateral load was performed and the connection behavior was discussed. From the test results, it was found that the initial rotational stiffness of pile-cap connection was affected by the length of pile-head inserted in footing and the location of longitudinal reinforcing bars. The types of pile and location of longitudinal reinforcing bars governed the behavior of pile-cap connection regarding load-carrying capacity, ductility, and energy dissipation.