• Title/Summary/Keyword: 기체 크로마토그래프-질량 분석기

Search Result 16, Processing Time 0.028 seconds

Organic Residues Analysis of Oil Bottle of Goryeo Dynasty Excavated from the Soejeoul Site, Geumneung-dong, Chungju (충주 금릉동 쇠저울유적 출토 고려시대 유병의 유기물 분석)

  • Yun, Eun Young;Kim, Suyeon
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.638-647
    • /
    • 2021
  • Organic residues are substances derived from diverse natural sources. Recent scientific analysis of organic residues has yielded important information in restoring the lifestyles of ancient peoples. In this study, the organic material contained within the celadon oil bottle of the Goryeo dynasty, excavated from the Soejoul site in Geumneung-dong, Chungju, was analyzed using Fourier-transform infrared spectroscopy (FT-IR) and gas chromatograph-mass spectrometer (GC-MS). The results showed that the organic materials in the bottle were plant-derived oils. In particular, polyunsaturated fatty acids and phytosterols were detected using GC-MS analysis. Sesamin components were also identified. Sesamin, which is a characteristic component of sesame seeds, is a lignan and an antioxidant. As the organic residues in the oil bottle were derived from sesame seeds, it is presumed that sesame oil was stored in the bottle.

Simultaneous Analysis of Pesticide Priority Pollutants in Soil (토양 중의 Pesticide Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung-Seok;Park, Young-Joo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.237-248
    • /
    • 1995
  • The simultaneous analysis of 16 organic pesticides, which are listed as a part of 129 priority pollutants by EPA(Environmental Protection Agency), was performed by GC-ECD(electron capture detector) and GC/MS-SIM(selected ion monitoring). Two extraction procedures from SW-846, sonication extraction and Soxhlet extraction, were somewhat modified and compared as an extraction and concentration method for the analysis of priority pollutants in soil. Accuracy and precision of the methods were reported from the calculation of mean recovery, mean relative standard deviation, and method detection limit.

  • PDF

Simultaneous Analysis of Pesticide Priority Pollutants in Water Samples (수질 시료 중의 Pesticide Priority Pollutants 동시분석에 관한 연구)

  • Kim Kye-Young;Kim Chong-Hyeak;Lee Sueg-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.590-598
    • /
    • 1993
  • The simultaneous analysis of samples, 16 organic pesticides in water among 129 priority pollutants listed by EPA, was performed by GC-ECD (electron capture detector) and GC/MS-SIM (selected ion monitoring). Two extraction procedures, liquid-liquid extraction (LLE) and solid-phase extraction (SPE), were studied as an extraction and concentration method. Accuracy and precision of the methods were measured by the calculation of mean recovery and mean relative standard deviation. Finally, the detection limits, the experimental limitations, and prospects were discussed.

  • PDF

Feasibility study of membrane interface for gas chromatograph-mass spectrometry (기체크로마토그래프-질량분석기의 실리콘 분리막 인터페이스의 유용성 연구)

  • Kang, Gil Seon;Lee, Dong Soo;Lee, Hwa Sim;Park, Chang Joon
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.495-501
    • /
    • 2008
  • Agilent 5973 GC-MS instrument was modified so that the capillary direct interface was removed and that a silicone membrane was installed between GC and MS. Feasibility study of the membrane interface GC-MS has been carried out. Vacuum of the mass spectrometer was not affected by the carrier gas flow rate up to $4.7m{\ell}/min$. As the carrier flow rate was increased, peak tailing was reduced and chromatogram peaks appeared earlier. Chromatogram peaks showed better separation and higher sensitivity as the membrane thickness was reduced from $127{\mu}m$ to $75{\mu}m$, and also as the interface temperature was increased. However, the membrane interface GC-MS had drawbacks such as background ions at 73 and 147 m/z and poor peak separation due to peak tailing.

Simultaneous Analysis of Semi-Volatile Organic Base/Neutral Priority Pollutants in Soil (토양 중의 비휘발성 염기/중성 유기 Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seok Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.6
    • /
    • pp.418-426
    • /
    • 1994
  • This study was aimed at the detection of 40 semi-volatile organic base/neutral compounds from soil among 129 priority pollutants listed by EPA. Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as a extraction and concentration method for priority pollutants in soil. Extracts were analyted by GC/MS-SIM(selected ion monitoring). The analytical methods were tested by standard compounds spiked into blank soil. Accuracy and precision of the methods were measured by calculation of mean recovery and mean relative standard deviation. And the method detection limits were estimated.

  • PDF

A case study of verifying a suicide by carbon monoxide intoxication committed by burning an ignition charcoal briquette (착화탄 연소에 의한 일산화탄소 중독사에서 자살입증에 관한 사례연구)

  • Sung, Tae-myung;Jo, Ju-ik;Ahn, Phil-sang
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.398-408
    • /
    • 2015
  • Carbon monoxide (CO) intoxication, arising from CO from an ignited charcoal briquette (ICB), is a popular means of committing suicide in Korea. Most CO intoxications are related to suicide attempts; however, the possibility of a homicide disguised as a suicide cannot be ruled out. Therefore, forensic investigation of the deceased and the crime scene is crucial to confirm that the deceased committed suicide. Detection of the components of an ICB on the objects suspected of being contacted by the deceased, such as the hands, nostrils, and doorknobs, is essential for linking the crime scene to the victim in the case of suicides by ignited ICBs. The traces from an ICB were analyzed by investigating the morphological characteristics and obtaining elemental compositions. The ICBs were completely different from blackened wood, as detected by discriminant analysis with the elements of carbon and oxygen. We analyzed one case of CO intoxication to demonstrate an excellent procedure for verifying whether a suicide occurred with an ICB. We employed SEM-EDX for the analysis of an ICB, microscope-FT/IR and pyrolysis-GC/MS for a partly burnt resin-type substance, GC/MS for diphenhydramine (a sleeping drug), and GC/TCD for the CO-Hb level. We detected traces of an ICB on the hands, nostrils, and doorknobs, which were all discriminated into an ICB group. Detection of ICB traces from the nostrils could indicate that the deceased started the fire themselves to commit suicide. The partially burnt black material was analyzed as an acrylronitrilestyrene polymer, which is normally used to make bags for carrying or wrapping and could be assumed to have been used to transport the ICB. Diphenhydramine, a sleeping drug, was detected at a level of 2.3 mg/L in the blood, which was lower than that in fatal cases (8-31 mg/L; mean 16 mg/L). A CO-Hb level of 79% was found in the blood, which means that the cause of death was CO intoxication. The steps shown here could represent an ideal method for reaching a verdict of suicide by CO intoxication produced by burning an ICB in a sealed room or a car.

Development of Rapid Analysis Method for Pesticide Residues by GC-MS/MS (GC-MS/MS를 이용한 잔류농약 신속검사법 개발)

  • Choi, Yong-Hoon;Nam, Hye-Seon;Hong, Hye-Mi;Lee, Jin-Ha;Chae, Kab-Ryong;Lee, Jong-Ok;Kim, Hee-Yun;Yoon, Sang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.292-302
    • /
    • 2005
  • Condition of Ion-Trap gas chromatography-mass spectrometry (GC-MS) for rapid screening of 206-pesticides residues in agricultural foodstuffs was optimized. As applying a wide-bore column (10 m${\times}$0.53 mm, DF 0.25 um) connected with a fused silica restrictor (0.6 m${\times}$0.1 mm), a significant retention time reduction was obtained. Additionally, the shape of peaks was sharper and higher than classical GC's and GC-MS's, which allowed lower detection limits. To easily manage many spectral data, both of Electron Ionization(EI) and Chemical Ionization(CI) techniques were adopted in screening procedure. At the following steps, MS-MS technique were used to confirm screened analytes in complicated matrices.