• Title/Summary/Keyword: 기진 단층

Search Result 4, Processing Time 0.015 seconds

Relation of Intensity, Fault Plane Solutions and Fault of the January 20, 2007 Odaesan Earthquake (ML=4.8) (2007년 1월 20일 오대산 지진(ML=4.8)의 진도, 단층면해 및 단층과의 관계)

  • Kyung, Jai-Bok;Huh, Seo-Yun;Do, Ji-Yong;Cho, Deok-Rae
    • Journal of the Korean earth science society
    • /
    • v.28 no.2
    • /
    • pp.202-213
    • /
    • 2007
  • The Odaesan earthquake $(M_L=4.8)$ occurred near Mt. Odae, Jinbu-Myon, Pyongchang-Gun, Kangwon Province on January 20, 2007. It has a shallow focal depth about 10 km. Its felt area covers most of the southern peninsula except some southern and western inland area. The maximum MM intensity was VI in the areas including Jinbu, Doam, Kangreung, Jumunjin, and Pyongchang. In these areas, there was a very strong shaking that caused several cracks on the walls of buildings and houses, slates falling off the roof, tiles being off the wall, things falling off the desk, and rock falling from the mountains. In order to get fault plane solutions, grid searches were performed by fitting distributions of P-wave first-motion polarities and SH/P amplitude ratios for each event. The results showed that the main shock represented right-lateral strike-slip sense and two aftershocks, reverse sense. It seems that the seismogenic fault may be the NNE-SSW trending Weoljeongsa fault near the epicenter based on the distribution of epicenters (foreshock, main shock, and aftershocks), damage area, and fault plane solution. The distribution of the epicenters indicates that the length of the subsurface rupture is estimated to be about 2 km.

A Study of Standarzied Uptake Value Change on the Type of Mateiral (물질의 종류에 따른 표준섭취계수의 변화에 관한 연구)

  • Kim, Ki-Jin;Kim, Chong-Yeal;Bae, Seok-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3572-3578
    • /
    • 2011
  • In Positron Emission Tomography Computed Tomography, Standardized Uptake Value(SUV)is most generally used to discern tumors. However, SUV may be influenced other factors. In this study, experiment was conducted distrotion in image and change in SUV according to substance with GEMINI TF PET/CT of Philips.. SUV for materials resulted in 1.8 for stainless, 1.4 for stent, 2.4 for iodine contrast medium, 2.6 for Barium Sulfate, 1.6 for Gypsum, and 1.4 for paraffin respectively. The distortion of image was remarkable for the iodine contrast medium and Barium Sulfate. For the barium sulfate, the higher the density, the larger the distrotion of the images. As a result of test, it appeared that the metallic substance whose atomic number is low and contrast medium whose concentration is low didn't affect the distortion in image and the change in SUV. However, it tis necessary to minimize distortion in image and change in SUV, by removing the metallic substance and checking if there are contrast mdeium or before examination.

The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image (금속성 치아충전물이 PET/CT영상이 미치는 영향)

  • Kim, Ki-Jin;Bae, Seok-Hwan;Han, Sang-Hyun;Yu, Se-Jong;Lee, Bo-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.243-247
    • /
    • 2012
  • Beam hardening artifact happens in the CT image. when a PET/CT is conducted while there is a metallic dental implant. The artifact appears in the CT image can affect the PET image. When the patient with head and neck cancer has a metallic dental implant, Beam hardening artifact which was taken in th CT image can change the PET image and SUV value. Therefore, by Quantitative measure of the SUV according to the change in HU by the metallic dental implant, the appropriacy in the clinical application was assessed. The records of 47 patients with PET/CT August 2011. For the analysis, 2 region of interest were defined in area where CT and PET image. As a result of the experiment, if there in an implant, the HU and the SUV increased and there existed a statistically significant difference(p<0.01). Although this level of increase was not large compared with that in the patient who have no metallic dental implant, when a person has head and neck cancer, it is even more likely to be overestimated when diagnosing the cancer. When conducting PET/CT for the patient who have head and neck cancer, the physical biological parts should be considered in order not to make an error in decoding.

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.