• Title/Summary/Keyword: 기자력파

Search Result 1, Processing Time 0.02 seconds

Calculation of Unbalanced Magnetic Pull of Induction Motors due to Rotor Misalignment (경사 편심에 의한 유도전동기의 자기흡인력 평가)

  • Kim, S.H.;Yang, B.S.;Kim, H.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1321-1327
    • /
    • 2006
  • This paper presents the calculation of unbalanced magnetic pull (UMP) that causes rotor misalignment in induction motor. The excessive noise and vibration will be occurred by means of rotor misalignment. Angular misalignment of rotor will produce air-gap permeance wave which is function of axial and circumferential coordinate. In this paper, the UMP is calculated using permeance and magneto motive force (MMF) in the case of static and dynamic misalignment. Based on the percentage of misalignment, the result shows that the UMP and magnetic pressure are increased according to the increasing of misalignment. The UMP is occurred not only in It frequency component but also the others.