• Title/Summary/Keyword: 기울기 각도

Search Result 475, Processing Time 0.022 seconds

A Study on the Dynamic Range Expansion of the Shack-Hartmann Wavefront Sensor using Image Processing (영상처리 기법을 이용한 샥-하트만 파면 센서의 측정범위 확장에 대한 연구)

  • Kim, Min-Seok;Kim, Ji-Yeon;Uhm, Tae-Kyung;Youn, Sung-Kie;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.375-382
    • /
    • 2007
  • The Shack-Hartmann wavefront sensor is composed of a lenslet array generating the spot images from which local slope is calculated and overall wavefront is measured. Generally the principle of wavefront reconstruction is that the spot centroid of each lenslet array is calculated from pixel intensity values in its subaperture, and then overall wavefront is reconstructed by the local slope of the wavefront obtained by deviations from reference positions. Hence the spot image of each lenslet array has to remain in its subaperture for exact measurement of the wavefront. However the spot of each lenslet array deviates from its subaperture area when a wavefront with large local slopes enters the Shack-Hartmann sensor. In this research, we propose a spot image searching method that finds the area of each measured spot image flexibly and determines the centroid of each spot in its area Also the algorithms that match these centroids to their reference points unequivocally, even if some of them are situated off the allocated subaperture, are proposed. Finally we verify the proposed algorithm with the test of a defocus measurement through experimental setup for the Shack-Hartmann wavefront sensor. It has been shown that the proposed algorithm can expand the dynamic range without additional devices.

Soil Properties Affecting C-type slope as a Parameter for Silica Sorption of Soils (토양의 규산 흡착 지표인 C-type slope에 영향을 미치는 토양 특성)

  • Lee, Sang Eun;Lim, Woo Jin;Ahn, Jae Ho;Kim, Jeong-Gyu;Lim, Soo-Kil
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.6
    • /
    • pp.365-370
    • /
    • 2004
  • To invesligate the characteristics of silica sorption on soils silica sorption experiments were conducted with 9 soils at 4 pH levels (5, 6, 7, and 8). Silica sorption increased in great extent with increase of pH. At the same pH level silica sorption increased linearly with increase of equilibrium $SiO_2$ concentration. Silica sorption characteristics was C-type. The C-type slope, i.e., the slope of linear regression of silica sorption isotherm, increased exponentially with increase of pH in all soils. Log(C-type slope) increased linearly with increase of pH in all soils. The slopes of linear regression were similar in most soils from 0.29 to 0.34 except Sachon and Jonggog soil. None of the soil properties showed any correlation with the slope of linear regression of Log(C-type slope) to pH. Only $Fe_o$ (oxalate extractable Fe oxides) was significantly correlated with the Log(C-type slope) at pH 7 in simple correlation analysis, and was shown to be the principal contributor as determined by standardized multiple linear regression.

A Cephalometric Study on factors affecting the FHI (Facial Height Index) in Angle's Class II division 1 malocclusion Patients (한국인 2급 1류 부정교합자의FHI(Facial Height Index)에 영향을 미치는 요소에 관한 두부방사선 계측학적 연구)

  • Park, Young-il;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.401-413
    • /
    • 1996
  • Facial vertical dyscrepancies is decided on the relationship between the anterior vertical facial height and posterior vertical facial height. Thus this study was conducted to determine the factors that affect the FHI, and classify the Class II div.1, malocclusion, which success is dependent on the vertical control according to the FHI, which is the ratio of antero-inferior facial height, posterio-inferior facial height ratio, and to use this as a guideline for treatment. Angle between palatal plane and Mandibular plane were in the order of RH, ID. Thus showing that interrelated angle was more inportant than the independent angle of both, palatal plane and Mandibular plane. The tendency of Cl II div.1. Malocclusion according to FHI, showed the Low group to have Mx. protrusion, prominent development of Mn. ramus, and the Mn. body length and ant. post. position was normal. The Normo group showed slight protrusion of the Maxilla,. The development of the ramus was less than normal and the Mn. was in a slight retruded position. The High group showed the Mx. in a normal position, the development of the Mn. ramus and body was the lowest, and the Mn. was in a posterior position. In observation of the factors affecting the FHI between each groups of Cl II div.l, malocclusion; In the Low group the MP- PP angle was very small, the ID was smililar to the normal group, but the RH was very large thus the FHI was increased. In the Normo group, the PP-MP angle was normal, ID was slightly smaller than the normal group and the RH was slightly smaller than the normal group, thus maintaining a normal FHI ratio. In the High group the PP-MP angle was very large, the ID was similar to the normal group, but the RH was smaller than the normal group thus the FHI was small.

  • PDF

A Characteristic of Deformation and Strength of Domestic Sands by Triaxial Compression Tests (삼축압축시험에 의한 국내 모래의 변형-강도 특성)

  • Park, Choon Sik;Kim, Jong Hwan;Park, Cheol Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.515-527
    • /
    • 2014
  • This study conducted experiment for understanding engineering characteristics of domestic sands by examining standard sand and sand from Yokji Island and Nakdong River in terms of confining pressure, $K_0$, over consolidation and relative density factors through triaxial compression test. The test showed that deviator stress by strain positively changed as confining pressure and relative density grow while $K_0$ and over consolidation factors do not directly correlated with it. Angle of internal friction decreases as confining pressure increases which strengthens contact force between particles, and declines as relative density drops, whereas $K_0$ and over consolidation factors hardly affect the results. When it comes to volumetric strain, volume expansion decreases as confining pressure increase due to crushability and rearrangement of particles while $K_0$ and over consolidation shows same movement unconditionally, and relative density appears compressed as it grows at the beginning however it expands as axial strain increases. Modulus of elasticity ($E_{sec}$) by strain has tendency into convergence resulting in initial secant modulus of elasticity ($E_{ini}$) > secant modulus of elasticity($E_{sec}$) > tangent modulus of elasticity ($E_{tan}$). On the other hand, it grows as confining pressure and relative density increase while indicating similar modulus of elasticity ($E_{sec}$) regarding on $K_0$ and over consolidation. Slope of critical line (M) tended to decrease as confining pressure increases, follow same line according to $K_0$, confining pressure and relative density, and increase as relative density grows.

SOFT TISSUE PROFILE CHANGE PREDICTION IN MAXILLARY INCISOR RETRACTION BASED ON CEPHALOMETRICS (두부방사선 분석에 의한 상악전치부 후방이동시 연조직 변화 예측에 대한 연구)

  • Choi, Jin-Hee;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.65-78
    • /
    • 1997
  • This study was carried out in order to determine soft tissue response to incisor movement and mandibular repositioning and to determine feasibility of predicting vertical and horizontal changes in soft tissue with hard tissue movement. For this study, cephalometric records of 41 orthodontically treated adult females who had Angle's Class II division 1 malocclusion were selected and stepwise multiple regression analysis was employed. Following conclusions were obtained by analysing the changes of soft tissue and hard tissue before and after treatment. 1. Hard tissue measurements that showed significant changes before and after treatment were horizontal and angular changes of maxillary incisor, horizontal,vertical and angular changes of mandibular incisor, overjet, overbite, interincisal angle, mandibular repositioning, A,B, skeletal convexity and soft tissue measurements that showed significant changes were horizontal, thickness and angular changes of upper lip, horizontal and angular changes of lower lip, interlabial angle, nasolabial angle labiomental angle, Sri, Ss, Si and soft tissue convexity(P<0.05). 2. All Soft tissue measurements changed significantly before and after treatment had between one and four hard tissue independent variables at statistically significant level, indicating that all soft tissue changes were direct relationship with hard tissue changes 3. Ova jet, horizontal change of maxillary incisor, horizontal change of maxillary root apex and horizontal change of pogonion entered into prediction equations most frequentely indicating that they were more significant variables in prediction of vertical and horizontal changes in the soft tissue with treatment, but vertical changes of mandibular incisor not entered any prediction equations, indicating that it was not considered a good predictor for soft tissue changes with maxillary incisor retraction. 4. Horizontal and vertical changes in subnasale were found to have most independent variables, significant at the 0.05 level in prediction-equations(${\Delta}$Sn(H):Ur, Is(H), Pg(H), UIA,${\Delta}$Sn(V): Is(H), Pg(H), overjet, A), indicating that subnasale changes are influenced by complex hard tissue interaction. 5. Multiple correlation coefficient($R^2$) of the soft tissue prediction equations ranges from 0.2-0.6.

  • PDF

Design and Analysis of LED.Optical Fiber Coupler for Efficient Line Lamps (효율적인 라인램프를 위한 발광다이오드-광섬유 결합기의 설계 및 해석)

  • Hong, Dae-Woon;Yoon, Myeong-Jung;Kim, Kyung-Ho;Yoo, Jae-Keun;Lee, Song-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • Line lamps, which utilize leaky optical fibers based on periodic bending of plastic optical fibers, are proposed. The LED-optical fiber coupler, the key component of the line lamp, is designed and analyzed. The analysis by the Monte Carlo photon simulation method has shown that the optical coupling efficiency is affected rather sensitively by $\theta_w$, the slanting angle of the reflecting cup sidewall and $\rho_{ref}$, the reflectivity of the reflecting cup. The optical coupling efficiency of the coupler reaches the maximum when $\theta_w$ is about $60^{\circ}$, which is significantly larger than $\theta_w=45^{\circ}$, the typical sidewall slanting angle of the reflecting cup adopted in most LED lamps. When the reflectivity of the reflecting cup is above 0.8, the optical coupling efficiency is larger than 80%, which is the typical efficiency to be achieved in LD-optical fiber coupler.

Experimental Examination of the Beer's law for Quantitative Electron Tomography (정량적 전자토모그래피를 위한 Beer's law의 실험적 검증)

  • Kim, Jin-Gyu;Song, Kyung;Lee, Su-Jeong;Jou, Hyeong-Tae;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.40 no.2
    • /
    • pp.117-123
    • /
    • 2010
  • This study has examined experimentally the Beer's law which is a precondition for quantitative electron tomography. We used carbon support film and latex spheres, which have similar absorption coefficients with biological samples, as the test samples to take a tilt-series of images for electron tomography. First, the 3D information of carbon film and latex spheres was obtained by electron tomography. Then, the regression analysis on the relationship between the intensities of the incident and the transmitted beams in a tilt series was carried out to examine the Beer's law. The regression results with RMS error of 0.976 show the linear intensity variations of the transmitted beam as the tilt angles were increased. In addition, the relative absorption coefficients of carbon support film and latex spheres calculated experimentally through the Beer's law were 1.71 (5) and 2.67 (6)/${\mu}m$, respectively. The absorption coefficients remained constant within a full tilt range. Therefore, it is expected that quantitative electron tomography could be performed for biological samples by applying Beer's law provided the exact intensity of incident beam can be obtained under the thoroughly controlled experimental conditions.

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

A Robust License Plate Extraction Method for Low Quality Images (저화질 영상에서 강건한 번호판 추출 방법)

  • Lee, Yong-Woo;Kim, Hyun-Soo;Kang, Woo-Yun;Kim, Gyeong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • This paper proposes a robust license plate extraction method from images taken under unconstrained environments. Utilization of the color and the edge information in complementary fashion makes the proposed method deal with not only various lighting conditions, hilt blocking artifacts frequently observed in compressed images. Computational complexity is significantly reduced by applying Hough transform to estimate the skew angle, and subsequent do-skewing procedure only to the candidate regions. The true plate region is determined from the candidates under examination using clues including the aspect ratio, the number of zero crossings from vertical scan lines, and the number of connected components. The performance of the proposed method is evaluated using compressed images collected under various realistic circumstances. The experimental results show 94.9% of correct license plate extraction rate.