• Title/Summary/Keyword: 기온저감

Search Result 122, Processing Time 0.029 seconds

A Study on the Factors Affecting Air Temperature on Roadside : Focusing on Road Conditions and Traffic Characteristics (도로 주변부 기온에 영향을 미치는 요인에 관한 연구: 도로조건과 교통특성을 중심으로)

  • Lee, Yuhwa;Yang, Inchul;Kim, Do-Gyeong;Lim, Ji Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1619-1629
    • /
    • 2013
  • It turned out that there was a direct or an indirect relationship among global warming, urban heat island effects, urban and traffic environments, and public's health. In particular, unusual climate phenomena such as frequent heavy rainfall and scorching heat in a row that had rarely happened before have a negative effect on quality of life for people living in urban areas. This study focuses on the effects of roadway geometric design and traffic conditions on air temperature of roadside in Seoul Metropolitan Areas, controlling of roadway micro-climate environment. Five roadway segments containing different roadway and traffic conditions in terms of traffic median with trees, street trees, traffic volume and average travel speeds were surveyed. According to statistical results(t-test) from three roadway air temperature regression model estimations, air temperature is found to be different from one another in three periods-morning, afternoon and evening. Regarding roadway geometric design, air temperature of urban roads with vegetated median strips is lower about 1.3~2.2 degrees in celcius. Higher traffic volumes per lane and lower average travel speeds will tend to increase roadside air temperature, and efficient traffic operation policies can protect from increasing roadside air temperature in urban areas.

A Study on the Analysis of Temperature Reduction Effect by the Types and Public Awareness of the Green Roof (옥상녹화의 녹화유형별 기온저감효과 및 시민의식 분석)

  • Lee, Chun-Woo;Kim, Soo-Bong;Moon, Hye-Shick;Jeon, Eun-Jeong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.316-320
    • /
    • 2009
  • Recently, concerns about conserving proper size of urban green spaces and accessibility are increasing, regarding it as a solution to diverse urban environmental problems including pollution, ecosystem deterioration, urban climate change. Artificial ground greening such as green roofs is regarded as the only alternative that can conserve green spaces which are impossible to be secured on the ground. However, green roofs are not popularized yet and levels are very low in provincial cities despite of related technology development and support systems of related agencies. Based on the background, this study tries to present a theoretical basis of methods for green roofs, conducting green roof simulations and collecting ideas about problems and improving measures from green roof users. Finally, it aims to offer base data which help establish policy direction for activation of green roof technology. As a result of a simulation for verifying temperature reduction effect, it was possible to affirm effect of a plot that green roofs applied. Especially, it was revealed that a green roof method using ground covers such as mixed planting was the most effective way to reduce temperature. Activation methods for green roofs based on this study are as follows: First, it is a priority to readjust systems related to green roofs. Second, citizens' active and voluntary participation must be attained. Third, it is required to establish detailed promotion procedures which aim at actual conduct and to maintain an expert department which is able to manage and control the establishment. After conduct, continuous aftercare stages are also needed.

  • PDF

Management Planning of Wind Corridor based on Mountain for Improving Urban Climate Environment - A Case Study of the Nakdong Jeongmaek - (도시환경개선을 위한 산림 기반 바람길 관리 계획 - 낙동정맥을 사례로 -)

  • Uk-Je SUNG;Jeong-Min SON;Jeong-Hee EUM;Jin-Kyu MIN
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.1
    • /
    • pp.21-40
    • /
    • 2023
  • This study analyzed the cold air characteristics of the Nakdong Jeongmaek, which is advantageous for the formation of cold air that can flow into the city, in order to suggest the wind ventilation corridor plans, which have recently been increasing interest as a way to improve the urban thermal environment. In addition, based on the watershed analysis, specific cold-air watershed areas were established and management plans were suggested to expand the cold air function of the Nakdong Jeongmaek. As a result of the analysis of cold air in the Nakdong Jeongaek, cold air was strongly generated in the northern forest of the Jeongamek, and flowed into nearby cities along the valley topography. On average, the speed of cold air was high in cities located to the east of the Jeongmaek, while the height of cold air layer was high in cities located to the west. By synthesizing these cold air characteristics and watershed analysis results, the cold-air watershed area was classified into 8 zones, And the plans were proposed to preserve and strengthen the temperature reduction of the Jeongmaek by designating the zones as 'Conservation area of Cold-air', 'Management area of Cold-air', and 'Intensive management area of Cold-air'. In addition, in order to verify the temperature reduction of cold air, the effect of night temperature reduction effect was compared with the cold air analysis using weather observation data. As a result, the temperature reduction of cold air was confirmed because the night temperature reduction was large at the observation station with strong cold air characteristics. This study is expected to be used as basic data in establishing a systematic preservation and management plan to expand the cold air function of the Nakdong Jeongmaek.

Monitoring Methods for the Effectiveness Evaluation of Grit Chamber and Temporary Reservoir in Urban Development Sites (도시개발현장의 침사지겸 저류지의 재해저감 효과평가를 위한 모니터링 방안)

  • Pyeon, Young-Beom;Jeong, Woo-Song;Song, Moon-Soo;Yun, Hong-Sik
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.101-102
    • /
    • 2022
  • 본 논문에서는 도시 개발현장의 재해저감시설 중 하나인 침사지겸 저류지의 효과평가를 위한 모니터링 방안을 제시하였다. 전 지구적으로 기온이 급격히 상승하고 있으며 이상 자연현상이 지속적으로 증가하고 있다. 특히 우리나라는 매년 태풍에 영향을 받고 여름에 강수량이 집중되고 있다. 개발 중 지표면이 침식에 노출되고 불투수면적의 증가로 홍수위험이 높아져 재해영향평가제도에 따라 침사지겸 저류지를 설치하여 토사의 하천 유출을 방지하고, 첨두유출을 완화시키고 있다. 설치 시 외국의 경험식과 재해영향평가서 기준 기상청 관측대의 30년 빈도 강우량을 사용하고 있으나, 유형 및 제원의 적절성의 효과평가 방안이 부재하다. 향후 이상기후로 강하고 잦은 폭우가 예상되며, 이로 인한 홍수 피해를 예방하기 위한 침사지겸 저류지에 대한 효과 평가 방안이 필요하다. 이에 침사지겸 저류지의 재해저감 효과평가를 위해 타 재해저감시설 모니터링 체계 분석을 통해 수위값과 퇴사위 계측을 활용한 침사지 겸 저류지의 모니터링 방안을 도출하였다.

  • PDF

Impact Assessment on the Change of Thermal Environment, According to the Hydraulic Characteristic Urban Regeneration Stream: Cheonggyecheon Case Study (도심재생하천 내 수리적 특성이 열환경 변화에 미치는 영향 평가: 청계천을 대상으로)

  • Kim, Jeong-Ho;Lee, Ju-Seung;Yoon, Yong-Han
    • Journal of Environmental Policy
    • /
    • v.14 no.2
    • /
    • pp.3-25
    • /
    • 2015
  • Our goal is to verify how changes in water's hydraulic characteristics after urban regeneration stream can affect any possible transformation of its thermal environment. To that end, we analyzed changes in numerous physical characteristics the subject stream along with the meteorological factors and thermal environment affected by it. Cheonggyecheon was selected as our subject as it is a great example of successful urban regeneration stream. As for physical characteristics, we allocated Type I (0.0%) and Type II (20.2%), depending on the green coverage ratio. As for numerical characteristics, at the point of Ba in which the riffle ends, the water temperature fell by $0.2^{\circ}C$ and the flow increased from 0.7m/s to 0.9 m/s with the dissolved oxygen increasing from 0.5mg/L to 0.6mg/L. As for meteorological factors surrounding the subject stream, the temperature dropped from $1.1^{\circ}C$ to $1.4^{\circ}C$ on average and relative humidity increased from 6.6% to 8.7%. Furthermore, there was an irregular change in wind velocity. According to the result of the Wet Bulb Globe Temperature (WBGT), the change in the values of Type I and II inside and on the surface of the subject stream was negligible. The downstream temperature in Type I fell from $0.3^{\circ}C$ to $0.6^{\circ}C$ and by $0.8^{\circ}C$ in Type II. As for vertical cooling effect, the change of water level was 120cm in Type I and 140cm in Type II. As for horizontal cooling effects, the value of Type I was increased from the point of Ba where the riffle ends and the value of Type II was on a steady decline.

  • PDF

The cooling effect of a paddy field area during summer (여름철 논에서의 기온저감 효과)

  • Song, Chul-Min;Kim, Jin-Soo;Park, Jong-Hwa;Jeong, Gu-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1497-1500
    • /
    • 2006
  • The cooling effect of paddy fields was compared with those of other land-use areas (upland, urban park, and urban residential area) during midsummer. The temperature were monitored using data logger at one hour intervals in study sites. Diurnal temperature range of study areas in clear days was larger than in cloudy days. Also, diurnal temperature ranges in paddy field, upland, and park areas were larger than those in the urban residential area during clear days. The paddy field or upland area has shown more remarkable cooling effect compared to urban residential areas: Mean duration of temperature below $25^{\circ}C$ in the paddy field area is longer(7 to 8 hours) than in the residential area; The time to fall to below $25^{\circ}C$ in the paddy field area is sooner than in the residential area; Mean daily minimum temperature in the paddy field area is much lower than in the residential area.

  • PDF

Impacts of Three-dimensional Land Cover on Urban Air Temperatures (도시기온에 작용하는 입체적 토지피복의 영향)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.54-60
    • /
    • 2009
  • The purpose of this study is to analyze the impacts of three-dimensional land cover on changing urban air temperatures and to explore some strategies of urban landscaping towards mitigation of heat build-up. This study located study spaces within a diameter of 300m around 24 Automatic Weather Stations(AWS) in Seoul, and collected data of diverse variables which could affect summer energy budgets and air temperatures. The study also selected reflecting study objectives 6 smaller-scale spaces with a diameter of 30m in Chuncheon, and measured summer air temperatures and three-dimensional land cover to compare their relationships with results from Seoul's AWS. Linear regression models derived from data of Seoul's AWS revealed that vegetation volume, greenspace area, building volume, building area, population density, and pavement area contributed to a statistically significant change in summer air temperatures. Of these variables, vegetation and building volume indicated the highest accountability for total variability of changes in the air temperatures. Multiple regression models derived from combinations of the significant variables also showed that both vegetation and building volume generated a model with the best fitness. Based on this multiple regression model, a 10% increase of vegetation volume decreased the air temperatures by approximately 0.14%, while a 10% increase of building volume raised them by 0.26%. Relationships between Chuncheon's summer air temperatures and land cover distribution for the smaller-scale spaces also disclosed that the air temperatures were negatively correlated to vegetation volume and greenspace area, while they were positively correlated to hardscape area. Similarly to the case of Seoul's AWS, the air temperatures for the smaller-scale spaces decreased by 0.32% ($0.08^{\circ}C$) as vegetation volume increased by 10%, based on the most appropriate linear model. Thus, urban landscaping for the reduction of summer air temperatures requires strategies to improve vegetation volume and simultaneously to decrease building volume. For Seoul's AWS, the impact of building volume on changing the air temperatures was about 2 times greater than that of vegetation volume. Wall and rooftop greening for shading and evapotranspiration is suggested to control atmospheric heating by three-dimensional building surfaces, enlarging vegetation volume through multilayered plantings on soil surfaces.

A Study on the Relationship between Land Cover Type and Urban Temperature - focused on Gimhae city - (토지피복유형 특성과 도시 온도의 관계 분석 - 김해시를 대상으로 -)

  • SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.65-81
    • /
    • 2019
  • This study analyzed the relationship of land cover type, urban temperature in Gimhae city, Gyeongsangnam-do, South Korea. Date were used for land cover map, MODIS LST, and detailed temperature data on the Korean Peninsula based on RCP between 2000 and 2010. The correlation between urban area and surface temperature was 0.417, 0.512 for agricultural area and -0.607 for forest area. The correlation between surface temperature and air temperature was 0.301. The relationship with air temperature was analyzed as 0.275 for urban area, agriculture area 0.226, forest area 0.350. Urban and agricultural areas showed increased surface and air temperature as the area increased, while forest areas showed opposite improvements. In structural equation models, urban and agricultural areas had direct effects on the rise of surface temperature, whle forest areas had direct effects on the reduction of air temperature. In the future, it is necessary to use measured temperature data near the surface to understand the relationship between surface temperature and temperature according to the changes in spatial characteristics, which will prepare measures for urban heat island mitigation at the level of urban and environmental planning.