• Title/Summary/Keyword: 기밀성 실험

Search Result 81, Processing Time 0.022 seconds

A Techniques for Information Hiding in the Steganography using LSB and Genetic Algorithm (유전적 알고리즘과 LSB를 이용한 스테가노그래피의 정보은닉 기법)

  • Ji, Seon-Su
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.3
    • /
    • pp.277-282
    • /
    • 2018
  • The goal of the secret message communication on the internet is to maintain invisibility and confidentiality. Digital steganography is a technique in which a secret message is inserted in a cover medium and transmitted to a destination so that a third party can not perceive the existence of the message itself. Steganography is an efficient method for ensuring confidentiality and integrity together with encryption techniques. In order to insert a secret (Hangul) message, I propose a image steganography method that the secret character is separated and converted into binary code with reference to the encryption table, the cover image is divided into two areas, and the secret message and the right l-LSB information of the second area are encrypted and crossed, concealing the k-LSB of the first region. The experimental results of the proposed method show that the PSNR value is 52.62 and the acceptable image quality level.

Numerical Evaluation of Excavation Damage Zone Around Tunnels by Using Voronoi Joint Models (Voronoi 절리모델에 의한 터널 주변 굴착손상권(EDZ)의 해석 사례)

  • Park, Eui-Seob;Martin, C. Derek;Synn, Joong-Ho
    • Tunnel and Underground Space
    • /
    • v.18 no.5
    • /
    • pp.328-337
    • /
    • 2008
  • Quantifying the extent and characteristics of the excavation damage zone(EDZ) is important for the nuclear waste industry which relies on the sealing of underground openings to minimize the risk for radionuclide transport. At AECL's Underground Research Laboratory(URL) the Tunnel Sealing Experiment(TSX) was conducted and the tunnel geometry and orientation relative to the stress field had been selected to minimize the potential for the development of an EDZ. The extent and characteristics of the EDZ was measured using velocity profiling and permeability measurements in radial boreholes. The results from this EDZ characterization are used in this paper to evaluate a modeling fir estimating the extent of the EDZ. The methodology used a damage model formulated in the Universal Distinct Element Code and calibrated to laboratory properties. This model was then used to predict the extent of crack initiation and growth around the TSX tunnel and the results compared to the measured damage. The development of the damage zone in the numerical model was found to be in good agreement with the field measurements.

Study on characteristics of compression and transportation of syngas produced from gasification process of high-calorific waste and Sewage Sludge (고발열량폐기물 및 탈수슬러지 혼합가스화를 통해 생산된 합성가스 압축, 이송 운전 특성)

  • Park, Soo-Nam;Ku, Jae-Hoi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.832-835
    • /
    • 2009
  • 폐기물의 감량화 및 자원화 기술 중 가장 대표적인 기술로 폐기물의 가스화 용융 기술을 들 수 있다. 폐기물 가스화 용융 기술은 폐기물 내의 탄소 및 수소 성분은 가스화 하여 CO, $H_2$가 주성분인 합성가스(synthesis gas, syngas)로 전환하고, 불연물은 용융하여 환경적으로 무해한 슬래그 또는 금속으로 회수하는 기술이다. 본 연구에서는 고발열량폐기물과 탈수슬러지 혼합가스화를 통하여 생산된 합성가스를 합성가스 압축기를 통하여 유용한 원료물질을 제조하는 공정인 수성가스 전환 반응(water gas shift reaction)과 가스화 반응기의 보조연료로 투입하기 위한 합성가스 압축, 이송 시스템의 운전 특성을 고찰하였다. 그 결과 고발열량폐기물과 탈수슬러지 혼합가스화에서 합성가스는 안정적으로 발생하였으며, 합성가스 압축, 이송시스템을 위한 정제설비에서의 분진제거는 99.07 %의 효율을 얻었고, 또한 합성가스 재순환 장치의 성능시험을 통하여 대기 중의 산소가 유입이 안 되는 기밀성을 확인하였다. 합성가스 압축, 이송 공급 유량 제어 실험 결과로는 합성가스 압축기 기동 시 합성가스 압축압력과 공급유량은 비례적으로 증감하는 것을 알 수 있었다.

  • PDF

Experimental Research of Window Air Tightness and Opening Force with Respect to Mohair Number, Clearance and Shortened Length (모헤어 개수, 틈새 길이 및 축소된 길이의 창문 기밀성 및 개폐력에 대한 실험적 연구)

  • Kim, Seung Jae;Park, Jong Jun;Kim, Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.195-203
    • /
    • 2018
  • Mohair is widely used as an airtight material for filling the gap between a window frame and sash. The purpose of this study is to investigate infiltration rate and opening force of sliding windows according to the mohair installation conditions. Infiltration experimental apparatus was set up, and the experimental results were applied to windows to find a correlation between infiltration rates and opening forces. When 4 rows of mohair were installed, the infiltration rate increase became 27.1% per clearance length increase of 1 mm, and the infiltration rate decrease became 5.7% per shortened length increase of 0.1 mm. For 4 rows of mohair, the opening force decreased by 28.2% as the clearance increased by 1 mm, and it increased by 9.3% as the shortened length increased by 0.1 mm.

A Method to Improve Energy Efficiency for IoT Using SSL/TLS on Wireless Network (무선 환경에서 SSL/TLS를 사용하는 IoT의 에너지 효율성 향상을 위한 기법)

  • Chung, Jin Hee;Cho, Tae Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.3
    • /
    • pp.661-666
    • /
    • 2016
  • The Internet of Things (IoT) is an infrastructure of physical objects that could be connected to the Internet. Most of these are low performance to ensure a reasonable cost for the smart physical objects. Thus, these devices usually use a lightweight messaging protocol: message queue telemetry transport with SSL/TLS. Cipher suites in device are fixed by default and selected based on preference in SSL/TLS. However, the selected cipher suite provides high security level more than expected. This limitation causes energy waste and overhead of devices. In order to counter this problem, we proposed fuzzy logic based cipher suite decision method to improve energy efficiency. Our proposed method saved 36.03% energy.

A Study on the Damage Evaluation of Polyethylene Pipe by Squeeze-off (스퀴즈오프에 따른 PE배관의 손상평가 연구)

  • Ho seong Seo;Hwa young Lee;Jae-hun Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • PE piping, which has advantages in terms of construction convenience and economy, is widely used for underground burial in the domestic urban gas field. These PE pipes use squeeze-off in many sites to block gas flow during maintenance and repair work. Squeeze-off refers to a method of compressing a PE pipe to block fluid flow, and damage may occur due to the nature of construction in which the pipe is deformed by physical force. In order to prevent damage to PE pipes due to squeeze-off, the main points to be reflected in the squeeze-off operation procedures such as proper compression range, use pressure, and diameter were derived through damage assessment and confidential test according to the compression rate. The compression experiment for PE pipe damage assessment was conducted while changing the compression rate (20%~40%), the pressure of use (2.8 kPa, 25 kPa, 70 kPa), and the pipe diameters (63 mm, 90 mm, 110 mm). As a result of damage assessment according to the compression rate, damage occurred in pipes with compression rates of 45%(110mm) and 73%(63mm), which are for analyzing the effect of excessive compression. In addition, the leakage test was conducted using Ar(argon) during the squeeze-off, and as a result of the experiment, leakage occurred under the conditions of 70kPa and 110mm of pipe. As a result of this study, it was confirmed that squeeze-off for airtightness should be carried out in pipes within a range not exceeding 25 kPa and 90 mm pipes, and the appropriate compression rate to prevent damage to PE pipes is 30%.

Dynamic Copy Security Protocol In Real-Time Database Systems (실시간 데이터베이스 시스템에서의 동적 복사 보안 프로토콜)

  • Park, Su-Yeon;Lee, Seung-Ryong;Jeong, Byeong-Su;Seung, Hyeon-U
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.8
    • /
    • pp.955-963
    • /
    • 1999
  • 다단계 보안 실시간 데이타베이스 시스템은 데이타베이스의 일관성 유지와 실시간 요구인 마감시간의 만족, 그리고 기밀성을 띤 데이타가 노출될 수 있는 비밀채널(covert-channel)의 방지라는 요구사항을 모두 만족해야 한다. 기존의 SRT-2PL(Secure Real-Time 2 Phase Locking)은 원본과 복사본으로 데이타 객체를 분리시켜 다른 등급간에 불간섭(non-interference)을 유지하여 비밀채널의 방지를 가능하게 하였으나, 복사본이 모든 데이타 객체에 대해 항상 존재하므로 메모리의 낭비가 있을 수 있고, 복사본의 갱신을 위한 갱신 큐의 관리에 따르는 오버헤드와 그에 따른 예측성 결여라는 문제점을 갖고 있다. 이를 개선하기 위하여 본 논문에서는 다단계 보안 실시간 데이타베이스 시스템의 요구사항을 모두 만족하는 동적 복사 프로토콜을 제안한다. 동적 복사 프로토콜은 로킹 기법을 기초로 동작하고, 트랜잭션의 작업에 따라 동적으로 복사본을 생성하고 삭제한다. 모의 실험 결과 제안한 동적 복사 프로토콜은 비밀채널을 방지하고 동적인 복사본의 생성으로 SRT-2PL의 단점인 메모리 낭비를 줄일 수 있으며, 예측성을 높여 마감시간 오류율을 감소시켰다.Abstract Concurrency control of real-time secure database system must satisfy not only logical data consistency but also timing constraints and security requirements associated with transactions. These conflicting natures between timing constraints and security requirements are often resolved by maintaining several versions(or secondary copies) on the same data items. In this paper, we propose a new lock-based concurrency control protocol, Dynamic Copy Security Protocol, ensuring both two conflicting requirements. Our protocol aims for reducing the storage overhead of maintaining secondary copies and minimizing the processing overhead of update history. Main idea of our protocol is to keep a secondary copy only when it is needed to resolve the conflicting read/write operations in real time secure database systems. For doing this, a secondary copy is dynamically created and removed during a transaction's read/write operations according to our protocol. We have also examined the performance characteristics of our protocol through simulation under different workloads while comparing the existing real time security protocol. The results show that our protocol consumed less storage and decreased the missing deadline transactions.

A Study on Fire Resistance Characteristics of the Vacuum Pressurized Wood Fire Door (진공가압식 목재방화문의 내화특성 연구)

  • Kim, In-Beom;Cha, Jeong-Min;Hyun, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.351-353
    • /
    • 2010
  • 건축물에서 방화, 방음, 기밀, 단열 등의 용도로 사용되어지는 방화문은 외관의 단순함과 재질의 제한성 때문에 선택의 폭이 넓지 않았으나 최근에는 외관의 미려함을 고려하면서도 친환경성을 부여한 방화문들이 등장하고 있다. 하지만 방화문으로서 갖추고 있어야 하는 화재발생 시에 일정시간이내로 내화성을 부여해야 하는 측면에서는 어려움이 있다고 하겠는데 특히 목재방화문의 경우에는 경량화되면서도 내화성을 지닐 수 있는 방화문이 더더욱 요구되어지고 있기 때문에 목재방화문에 관한 내화특성을 실험을 통해 측정하였으며 화재안전성을 평가해 보았다.

  • PDF

A study on vulnerabilities of serial based DNP in power control fields (전력 제어시스템의 시리얼 기반 DNP통신 취약점에 관한 연구)

  • Jang, Ji Woong;Kim, Huy Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.6
    • /
    • pp.1143-1156
    • /
    • 2013
  • Power control system like SCADA(Supervisory Control And Data Acquisition) is gathering information using RS232C and low-speed analog communication network. In general, these methods are known as secure because of the secure characteristics from the analog based communication network and serial communication. In this study, first we build DNP communication environment using commercial power control simulator and find some vulnerabilities by testing from the viewpoint of confidentiality, integrity and availability. Consequently, we see the necessity of a valid method for authentication and data encryption when gathering information, even though that is known as secure so far. Discussion of needs of DNP authentication and data encryption is started about several years ago, but there is still nowhere applied that on real environment because the current methods can not fully meet the security requirements of the real environment. This paper suggests a solution to the vulnerabilities, and propose some considerations for enhancing power control system's security level by applying DNP authentication and data encryption.

Air-tightness Test by Silicagel on Museum Cases (조습제(燥濕濟)(Art-Sorb)를 이용한 벽부형진열장(壁附形陳列欌) 밀폐도(密閉度) 간접측정(間接測淀))

  • Yu, Hei-sun;Kim, Myoung-nam;Lee, Sung-eun
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.71-78
    • /
    • 2001
  • The airtightness of museum cases in museums was measured by using CO2 tracing gas, but it has been pointed that it has a problem with measuring the airtightness of a museum case which has a hole inside before it is used or while is being used. So studies tried to come up with alternatives which make it possible to measure the airtightness of a museum case before it is used or while it is being used if necessary by indirectly measuring the airtightness of the museum case without changing its form. Indirect measuring is done by measuring the change of Art-sorb weight and the change of temperature and humidity inside the museum case. Experiments were made for 12 days with three builtin wall case installed at the same place without turning on the lights but with Art-sorb and the data logger of temperature and humidity put into museum case. The change rate was produced with the change of temperature and humidity inside the museum case divided by that of those around museum case. As a result, the temperature change rate of museum case A(0.67) was lower than that of museum case B(0.69) or museum case C(0.79). The humidity change rate of museum case A(0.12) was lower than that of museum case B(0.19) or museum case C(0.72) showing that its airtightness was the best. Also in the direct airtightness measurement by CO2 tracing gas, the air exchange rate was compared with the humidity change rate by Art-sorb in the indirect measurement.