• Title/Summary/Keyword: 기류

Search Result 700, Processing Time 0.033 seconds

Effects of Air Current Speed on the Microclimates of the Plug Stand under Artificial Light (기류속도가 인공광하에서 공정육묘 개체군의 미기상에 미치는 영향)

  • 김용현;고재풍수
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.160-166
    • /
    • 1996
  • Objective of this study was to investigate the effects of all current speed on the microclimates above and inside the plug stand under artificial light. Maximum air temperature appeared near the top of the plug stand. Difference in air temperature inside the plug stand increased with the decreasing air current speed. Difference in relative humidity(DRH) to the relative humidity at the Inlet of the main air flow conditioner Inside and above the plug stand decreased with the increasing air current speed. Relative humidity inside the plug stand was 10-15% higher than that above the plug stand. DRH inside a stand of plug at air current speed of 0.3m s$^{-1}$ was about two times as many as that at air current speed of 0.9 m s$^{-1}$ . DRH inside the plug stand was 2.8-6.5% higher at LAI of 2.6 than that at LAI of 0.5. Gradient for the vapour pressure deficit was distinctly appeared at the low air current speed. Direction of vapour pressure flux is from the medium surface upwards. Difference in vapour pressure(DVPD) to the vapour pressure deficit at the inlet of the main air flow conditioner inside and above the plug stand decreased with the increasing height above the medium surface. DVPD inside the plug stand was 0.3-0.4㎪ higher at air current speed of 0.9m s$^{-1}$ than that at air current speed of 0.3m s$^{-1}$ . Results for the effects of air current speed on the relative humidity and vapour pressure deficit indicated that the microclimates above and inside the plug stand at the rear region in plug trays were slightly unfavorable compared to those at middle region.

  • PDF

Physiological Analysis for the Evaluation of Comfort Flow n Air Conditioner (에어컨의 쾌적기류 평가를 위한 생리신호 분석)

  • Lee, Nak-Bum;Im, Jae-Joong;Choi, Ho-Seon;Lee, Ju-Youn;Huh, Deok;Kum, Jong-Soo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.136-140
    • /
    • 2001
  • 본 연구는 절전기능과 인체순응을 고려하여 개발된 에어컨의 쾌적기류를 평가하기 위해 기존 에어컨에 활용되어지고 있는 정속풍, 변동풍과 새롭게 적용되고 잇는 개발풍을 비교하고자 수행하였다. 20명의 남녀 피험자를 대상으로 심전도를 측정하고 HRV 분석을 실시하여 남녀별로 비교한 결과 남녀 모두 개발풍, 변동풍, 정속풍의 순서로 HF/LF 값이 높게 나타났으며, 여성의 경우 정속풍은 무자극 조건에서보다 낮은 HF/LF 값을 나타내었다. 그리고 무자극에 대해서는 여성의 경우보다 남성의 경우가 변동풍과 개발풍의 기류제어 조건에서 크게 반응하였다. 남녀모두를 평균한 기류자극별 비교분석에서는 개발풍에서 가장 높은 HF/LF 값을 보였으며, 개발풍과 변동풍이 정속풍에 대하여 유의미한 차이를 나타내었다. 개인별로 각 자극에 대한 HF/LF 값을 계산하열 각 조건들에 대한 선호도를 조사한 결과, 14명이 개발풍에서 가장 높은 HF/LF 값을 나타내었고, 6명의 피험자는 변동풍에서 가장 높은 HF/LF 값을 보였다. 본 연구의 결과 새롭게 제시된 개발풍이 기존의 정속풍이나 변동풍에 대하여 더욱 쾌적한 기류임을 알 수 있었다.

  • PDF

Computational Analysis of Air Flows Inside Korean Traditional House (친환경 전통건축의 내부기류 전산해석)

  • Kim, Jay-Won;Aan, Eun-Yeong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.3
    • /
    • pp.380-387
    • /
    • 2012
  • The present investigation is to examine the thermal behaviors of air flows inside Korean traditional house made of the construction materials transmitted. The methodology is numerical predictions of air flows depend on the temperature distribution inside the indoor spaces. The transient computational simulations are performed along with the different house types, weather condition, and operating time. Thermal properties of building units have been obtained by the parallel measurements and utilized in the numerical works. Consequently, the details of flows and temperature of air in the houses illustrate the thermal design of the traditional Korean house satisfy the requirements of human living.

Symptom Questionnaire and Laboratory Findings in Subjects with Airflow Limitation: a Nation-wide Survey (기류 폐쇄(Airflow Limitation)의 유무와 호흡기 증상 및 검사실 성적에 관한 연구: 국가 단위 실태 조사)

  • Hwang, Yong Il;Kim, Young Chul;Lee, Jae Ho;Kang, Min Jong;Kim, Dong Gyu;Kim, Soo Ock;Jang, Tae Won;Lee, Min Ki;Ahn, Youngsoo;Yoo, Jee Hong;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.480-485
    • /
    • 2007
  • Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation that is not fully reversible. COPD has systemic effects, such as skeletal muscle dysfunction and abnormal weight loss. It also has been suggested that COPD is related to other chronic disease, such as cardiovascular disease, osteoporosis, and anemia. The aim of this study was to evaluate a symptom questionnaire and laboratory findings in subjects with air flow limitation. Methods: We evaluated a symptom questionnaire and laboratory findings in subjects with airflow limitation detected by spirometry in conjunction with the Second Korean National Health and Nutrition Examination Survey. A total of 9,243 adults over the age of 18 were recruited. Among the adults, we finally analyzed 2,217 subjects who met the acceptability and repeatability criteria of spirometry, showed normal findings on chest radiography, and were older than 40 years of age. Results: There were 288 subjects with airflow limitation as determined by spirometry. The frequency of respiratory symptoms such as cough, sputum and wheezing were significantly higher in subjects with airflow limitation (p <0.01). Hemoglobin and hematocrit levels were higher in subjects with airflow limitation (hemoglobin level 13.98 mg/dL vs. 13.62 mg/dL, hematocrit 42.10% vs. 40.89%; p<0.01). The HDL cholesterol level was lower in subjects with airflow limitation (44.95 mg/dL vs. 45.60 mg/dL; p<0.01). There was no significant difference in the total cholesterol, triglyceride, blood urea nitrogen, creatinine, and fasting glucose levels. Conclusion: In subjects with airflow limitation, prevalence of respiratory symptoms was higher than in normal spirometry subjects and the levels of hemoglobin and the hematocrit were higher. The HDL cholesterol level was lower in subjects with airflow limitation.

A Study on the Development of Circuit Breaker Testing System (차단기 특성 시험 시스템의 개발에 관한 연구)

  • Kim, Dong-Su;Won, Ho-Sung;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.650_651
    • /
    • 2009
  • 현재 한국전기연구원에서는 년간 약 1,000여대 이상의 차단기류에 대하여 사용전 검사 시험을 실시하고 있다. 차단기류의 사용전 검사 시험 항목은 개폐 특성에 대한 검증이 주를 이룬다. 현재 사용하고 있는 차단기 개폐특성 시험 설비는 약 20여년을 사용하여 보수가 필요한 시점에 도달하였다. 본 논문에서는 차단기류의 개폐특성 시험에 사용하던 차단기 특성 시험 시스템의 단점을 보완하여 시험의 신뢰성 및 사용자 편의성을 향상시킨 시험 시스템을 개발하고자 한다.

  • PDF

JET MOMENTUM CRITERIA FOR INLET CONTROL TO REDUCE WIND EFFECTS ON THE AIR DISTRIBUTION IN A SIDE-WALL-INLET VENTILATION SYSTEM (SIDE-WALL-INLET 환기시스템 축사에서 유입구의 컨트롤을 위한 젯트모멘텀)

  • ;Guoqiang Zhang
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.51-55
    • /
    • 1997
  • 국내의 축사는 윈치커튼의 위치를 조절하여 줌으로써 내부의 기류를 교환하는 개방형 축사가 대부분을 차지하고 있다. 개방형 축사의 환기는 외기풍속의 영향에의해 내부 기류의 흐름이 형성되어 바람이 없는 고온기에는 내부의 기류혼합이 잘 되지 않기 때문에 고온으로 인한 내부의 환경이 열악하다. 따라서 자연환기 축사에 배기팬 또는 입기팬을 설치하는 조합형 환기 축사가 주를 이를 것으로 판단된다. (중략)

  • PDF

BUSINESS GUIDE_정부시책 - "변화와 혁신으로 신가치를 창조하는 기업" - Panasonic 파나소닉전공신동아(주) -

  • 한국전기제품안전협회
    • Product Safety
    • /
    • s.193
    • /
    • pp.48-51
    • /
    • 2010
  • 파나소닉전공신동아(대표이사 배홍기)는 1988년 창립하여 지금까지 가정용전기기인 누전차단기류, 배선용차단기류, 옥내용소형스위치류, 소켓류, 배선용꽂음접속기류, 전자식스위치류, 주택용분전반류 등을 제조 판매하는 회사로써 국내 NO.1의 기업으로 성장하였다. 주택 환경의 급격한 변화에 대응하고 안전은 물론이고 귀족적이고 고급스런 디자인에 시공의 편리성까지 도모한 획기적인 제품을 생산하고 있다. 또한, 파나소닉전공신동아는 지속적인 연구개발(R&D) 투자와 함께 신제품을 출시하는 기술집약형 기업으로 손꼽히며 최초라는 수식어가 항상 따라 붙는다.

  • PDF

General Concepts of Chronic Obstructive Pulmonary Disease (만성 폐쇄성 폐질환(COPD)의 일반적 개념)

  • Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.205-214
    • /
    • 1994
  • 만성 폐쇄성 폐질환(COPD)은 하부 기도 즉 말초기도의 지속적인 미만성 폐쇄로 인하여 불가역성 기류폐쇄를 나타내는 질환을 말하며, 임상적으로 만성 기관지염과 폐기종으로 분류할 수 있으나, 이들은 기능적으로나 병리적으로 서로 중첩되어 임상적으로 명확하게 구별할 수 없기 때문에 만성적, 비특이적으로 진행하는 기류폐쇄의 포괄적인 용어로 COPD를 사용한다. COPD의 특징적인 병리변화는 소기도 즉 막성 세기관지염과 호흡세기관지염이며, 호흡세기관지염을 동반하는 폐기종의 중증도가 기류폐쇄의 정도를 결정하는 중요한 인자로 작용한다.

  • PDF

Development of Comfort Sensing System for Human Environment (실내 환경의 쾌적도 측정시스템 개발)

  • Kang, Jeong-Ho;Lee, Jae-Yong;Kim, Woo-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.317-321
    • /
    • 2006
  • 본 연구는 웰빙 환경 조성에 적합한 습도센서, 온도센서와 기류센서를 이용한 쾌적도 측정시스템에 관한 것이다. 이 측정시스템이 나타내는 쾌적도는 기류와 온도에 민감하게 나타났다. 시스템을 위한 온도와 습도 일체형 센서와 기류센서를 설계 및 제작하고, 마이크로 컨트롤러에서 센서 신호를 측정하여 ISO7730에서 나타내는 예상온열 감지수(PMV)와 쾌적감 지수(CSV)를 계산하고, 각각의 계산 값을 LCD에 표시하도록 하였다. 인위의 환경에서 실험한 결과, 본 시스템이 공기조화시스템, 자동차 기류조정시스템, 가정과 사무실 병원 등의 많은 분야에 적용이 될 수 있음을 알 수 있었다.

  • PDF

The Analysis of Indoor Thermal Environment for Air Condition System in Dome Stadium (돔경기장의 공조방식에 따른 겨울철 열환경 분석)

  • Seok, Ho-Tae;Yang, Jeong-Hoon;Chae, Mun-Byoung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.2
    • /
    • pp.53-63
    • /
    • 2009
  • In this study selected the domestic dome stadium, and analyzed the indoor airflow and temperature distribution application to existing or abroad air condition system in winterabWe examined the appropriateness of flow guiding fans installed to mitigate the high-temperature.

  • PDF