• Title/Summary/Keyword: 기동성 분석

Search Result 222, Processing Time 0.02 seconds

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

A survey on daily physical activity level, energy expenditure and dietary energy intake by university students in Chungnam Province in Korea (충남지역 대학생의 신체활동수준, 에너지소비량 및 에너지섭취량 조사)

  • Kim, Sun Hyo
    • Journal of Nutrition and Health
    • /
    • v.46 no.4
    • /
    • pp.346-356
    • /
    • 2013
  • This study investigated the daily physical activity level, energy expenditure, energy balance, and body composition and their relationship with university students. The participants were 130 male students ($19.5{\pm}0.5$ yrs) and 139 female students ($19.5{\pm}0.3$ yrs) at a university in Chungnam province. Physical activity level was evaluated by an equation based on 24 hr-activity record and dietary nutrient intake was evaluated using the food record method during a three-day period consisting of two week days and one weekend. Body composition was measured using Inbody 430 (Biospace Co., Cheonan, Korea). As a result, mean body mass index (BMI) of subjects indicated that they had normal weight, however mean body fat ratio was $19.1{\pm}5.4%$ for males and $28.4{\pm}5.0%$ for females, indicating that they had higher than normal weight. Daily mean physical activity level was 1.55 for males and 1.47 for females, which was regarded as 'low active', respectively. Females had more light activity than males (p<0.01). Daily mean energy expenditure was $2,803.5{\pm}788.9$ kcal/d for males and $1,915.4{\pm}510.2$ kcal/d for females (p<0.001). Daily mean dietary energy intake was $2,327.0{\pm}562.5$ kcal/d for males and $1,802.1{\pm}523.6/d$ for females (p<0.001), and daily mean energy balance was $-476.5{\pm}955.9$ kcal/d for males and $-113.3{\pm}728.1$ kcal/d for females (p<0.01). Daily mean dietary intake of protein, vitamins, and minerals, except Ca, satisfied recommended nutrient intake. Daily energy expenditure was positively related to body weight (p<0.01), BMI (p<0.01), and fat free mass ratio (p<0.05), but was negatively related to body fat ratio (p<0.01). In conclusion, subjects had a negative energy balance and low physical activity. They had a normal weight by BMI but had a more fat than normal weight by body fat ratio. This appears to be related to their low physical activity. Thus, nutrition education should be provided for university students in order to increase their physical activity for maintenance of normal weight by body composition and health promotion.