• Title/Summary/Keyword: 기구

Search Result 9,334, Processing Time 0.046 seconds

A Study on Migration of Monomers from Kitchen Utensils Including PA, PU, ABS, and Acrylic Resin Plastics (폴리아마이드제 등 조리기구 중 모노머의 이행에 관한 연구)

  • Choi, Jae-Chon;Park, Se-Jong;Park, Geon-Woo;Min, Hye-Kyoung;Yang, Ji-Young;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • The purpose of our paper was to investigate the migration level of 4,4'-MDA(4,4'-methylenedianiline), 2,4-TDA(2,4-toluenediamine), aniline, acrylonitrile and methylmeth acrylate from plastic cookwares into food simulants and to evaluate the safety of each monomers. The test articles for monomers were PA (polyamide) items for 4,4'-MDA, 2,4-TDA and aniline, PU (polyurethane) items for 4,4'-MDA, ABS (acrylonitrile-butadiene- styrene) items for acrylonitrile, and acrylic resin items for methylmethacrylate. All the article samples of 321 intended for contact with foods were purchased in domestic market. 4,4'-MDA, 2,4-TDA and aniline were analyzed by LC-MS/MS (liquid chromatography -tandem mass spectrometer), acrylonitrile by GC-NPD (gas chromatography-nitrogen phos phorus detector) and methyl methacrylate by GC-FID (gas chromatography-flame ionization detector). The migration level of monomers were within the migration limits of Ministry of Food and Drug Safety (MFDS). As a result of safety evaluation, our results showed that the estimated daily intake (EDI, mg/kg bw/day)s were $2.39{\times}10^{-9}$ and $1.20{\times}10^{-9}$ for 4,4'-MDA and 2,4-TDA of PA, $4.32{\times}10^{-9}$ for acrylonitrile of ABS and $2.27{\times}10^{-7}$ for methylmethacrylate of acrylic resin. Reference Dose (RfD, mg/kg bw/day) of acrylonitrile and tolerable daily intake (TDI, mg/kg bw/day) of methacrylate were established respectively as 0.001 by EPA (US Environmental Protection Agency) and as 1.2 by WHO (World Health Organization). When comparing with RfD and TDI, the EDIs of acrylonitrile and methylmethacrylate accounted for $4.32{\times}10^{-4}%$ and $1.89{\times}10^{-5}%$ respectively.

Development of Abdominal Compression Belt and Evaluation of the Efficiency for the Reduction of Respiratory Motion in SBRT (체부 정위방사선치료 시 호흡운동 감소를 위한 복부 압박기구 개발 및 유용성 평가)

  • Hwang, Seon-Bung;Kim, Il-Hwan;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Jeong, Seong-Min;Kim, Gi-Hwan;Lee, Ah-Ram;Cho, Yu-Ra
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • Purpose: It's essential to minimize the tumor motion and identify the exact location of the lesions to achieve the improvement in radiation therapy efficiency during SBRT. In this study, we made the established compression belt to reduce respiratory motion and evaluated the usefulness of clinical application in SBRT. Materials and Methods: We analyzed the merits and demerits of the established compression belt to reduce the respiratory motion and improved the reproducibility and precision in use. To evaluate the usefulness of improved compression belt for respiratory motion reduction in SBRT, firstly, we reviewed the spiral CT images acquired in inspiration and expiration states of 8 lung cancer cases, respectively, and analyzed the three dimensional tumor motion related to respiration. To evaluate isodose distribution, secondly, we also made the special phantom using EBT2 film (Gafchronic, ISP, USA) and we prepared the robot (Cartesian Robot-2 Axis, FARARCM4H, Samsung Mechatronics, Korea) to reproduce three dimensional tumor motion. And analysis was made for isodose curves and two dimensional isodose profiles with reproducibility of respiratory motion on the basis of CT images. Results: A respiratory motion reduction compression belt (Velcro type) that has convenient use and good reproducibility was developed. The moving differences of three dimensional tumor motion of lung cancer cases analyzed by CT images were mean 3.2 mm, 4.3 mm and 13 mm each in LR, AP and CC directions. The result of characteristic change in dose distribution using the phantom and rectangular coordinates robot showed that the distortion of isodose has great differences, mean length was 4.2 mm; the differences were 8.0% and 16.8% each for cranio-caudal and 8.1% and 10.9% each for left-right directions in underdose below the prescribed dose. Conclusion: In this study, we could develop the convenient and efficient compression belt that can make the organs' motion minimize. With this compression belt, we confirmed that underdose due to respiration can be coped with when CTV-PTV margins of mean 6 mm would be used. And we conclude that the respiratory motion reduction compression belt we developed can be used for clinical effective aids along with the gating system.

  • PDF

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

A Comparative Study of Two Different Heel Lancet Devices for Blood Collection in Preterm Infants (미숙아에서 채혈을 위한 발뒤꿈치 천자시 두 종류 천자 기구의 비교)

  • Lim, Hyo-Bin;Rhu, Mi-Joo;Jung, Ji-Mi;Jeon, Ga-Won;Sin, Jong-Beom
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2010
  • Purpose: To evaluate two different heel lancet device in terms of pain response and success of the procedure in the preterm infants undergoing heel puncture. Methods: 100 preterm infants undergoing capillary blood gas analysis or capillary bilirubin monitoring underwent heel puncture, were randomly allocated to blood sampling from the heel with either a conventional manual lancet or an automatic incision device. Primary outcome measures included the Premature Infants Pain Profile (PIPP) score, total duration of procedure, number of heel puncture and number of bruise. The pain response was evaluated using PIPP score and the effectiveness was evaluated using three criteria: total duration of blood sampling, number of puncture, bruising of the heel or ankle. Statistical analysis was performed using the SPSS ver. 13.0 program. Difference between the groups were analysed with t test (continuous variables) and the Chi square test or Fisher test (categorical variables). Results: The mean PIPP score was 4.91 for the automatic lancet group compared with 5.84 for the conventional manual lancet group (P=0.0255).The number of pain scores above 7 during blood collection did not differ between two groups (P=0.2167). The procedure took less time to perform in the automatic lancet group (mean, 30.69 seconds) than in the conventional lancet group (mean, 48.92 seconds) (P<0.0001). Conclusion: This study demonstrated that the automatic lancet device causes less pain and a shorter procedure time than the conventional manual lancet in preterm infants undergoing heel puncture. On the basis of these results the automatic lancet device is very useful method for blood collection in preterm infants by heel puncture.

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향)

  • Sung, Hye-Jin;Ha, Jung-Hong;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.380-386
    • /
    • 2010
  • Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.

Electrical Drift Mobility in the Cholesteryl Benzoate (Cholestric 액정 Cholesteryl Benzoate에서 Drift Mobility측정)

  • 강태원;김화택
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.2
    • /
    • pp.19-21
    • /
    • 1978
  • The electrical drift mobility of charge carrier of Cholesteryl Benzoate was measured by Polarity inversion method in the temperature range 140~ 185$^{\circ}C$. with a view to revealing the mechanism of charge carrier transport. The electrical drift mobility of charge carrier of that increased from 2.5$\times$10-7$\textrm{cm}^2$/V.sec to 2.0$\times$10-6$\textrm{cm}^2$/v.sec as the temperature increased. As a result of the experiment, the mechanism of current transport is believed to be ionic mechanism.

  • PDF

Corrosion Mechanism of Zr-based Alloys in LiOH Solution (Zr합금의 LiOH 용액에서 부식기구 연구)

  • Jeong, Yong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.6 no.2
    • /
    • pp.188-196
    • /
    • 1996
  • LiOH 용액에서 핵연료피복관용 Zr합금의 부식이 가속되는 현상을 규명하기 위하여 autoclave를 이용하여 순수물, 다른 농도의 Li 용액 및 여러 가지 알카리 수산화물 조건에서 부식시험을 실시하였다. LiOH 용액에서 부식이 가속되는 현상은 용액 내에 Li 농도가 2.2ppm 이상에서부터 일어나기 시작하며 30ppm 이상에서는 급격한 가속 현상이 일어난다. 부식반응 동안에 발생되는 수소 흡수현상은 220ppm Li에서는 물에 비해 약 2배의 높은 수소흡수율을 나타내며 산화막은 주로 수소화물이 모여 있는 지역에서 우선적으로 성장한다. Li가속 부식기구와 관련하여 본 연구 결과는 지금까지 다른 연구자들이 제안한 부식 기구들과는 일치하지 않았다. LiOH 용액 내에서는 수소흡수와 수소화물 형성이 가속되고 이로 인해 산화막의 성질이 비보호성의 산화막으로 변함으로서 부식은 가속된다는 새로운 모델을 제시하였다.

  • PDF

Creep Properties of Grain Coarsened ODS MA NiAl (결정립 조대화된 기계적 합금화 ODS NiAl의 Creep 성질)

  • Eo, Sun-Cheol;Seo, Seong-Jae
    • Korean Journal of Materials Research
    • /
    • v.7 no.11
    • /
    • pp.942-950
    • /
    • 1997
  • NiAI기 산화물 분산강화(Oxide Dispersion Strengthende:ODS)합금을 기계적 합금화 (Mechanical Alloying: MA)방법으로 제조하였으며, 열간압축방법으로 성형하였다. 연이어 단순항온처리에 의한 정상결정립성장과 특성조건에서의 thermomechanical treatment 에 의한 이차재결정화를 유도하였다. 결정립 조대화된 ODSD MA NiAI의 creep 성질 및 이에 조대화된 미세조직은 creep 성질이 저하된 반면, 이차재결정화된 MA NiAI의 creep성질은 크게 향상되었다. 이 creep 성질의 향상은 이차재결정화의 특성인 급격한 결정립의 조대화, 분산상의 성장억제 및 grain aspect ratio의 증가에 기인한 것으로 사료되었다. 이차재결정화된 ODS MA NiAI의 creep또는 glide controlled dislocation creep임을 제시하지만, 전체 creep속도가 결정립 크기 및 grain aspect ratio의 영향을 크게 받은 것을 볼 때, 결정립계 미끄럼기구가 주 creep 기구와 조합되어 MA NiAI의 전체 creep기구에 영향을 준 것으로 추정할 수 있었다.

  • PDF

On Improvement of Cam Performance for Rapier Loom Beat Up Mechanism (레피어직기의 바디침 구동캠 성능향상에 관한 연구)

  • 권상석;신재균;전두환
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.139-142
    • /
    • 2003
  • 레피어 직기는 1,000rpm 이상의 워터제트와 에어제트 직기의 생산성에 미치지는 못하지만 제직 범위가 넓고 다양한 색사 사용이 가능하다는 장점으로 인해 고급직물을 생산하기 위해 오늘날에도 폭넓게 사용되고 있다. 현재는 외국 선진국뿐만 아니라 국내에서도 레피어직기는 제트직기와 더불어 주력개발기종 중의 하나이다. 근래 레피어직기의 개발방향은 고속화에 주력하고 있다. 레피어를 고속화하기 위한 시도는 위입구동부, 바디침기구, 개구부, 송출부 및 권취부 등 전반적으로 검토되어야 하지만 본 연구에서는 바디침기구의 고속화를 위해 바디침기구의 구동원이 되는 구동캠의 성능향상에 목적을 두고 수행되었다. (중략)

  • PDF

국제항로표지협회(IALA) e-Navigation 추진현황 및 동향

  • Gong, Hyeon-Dong;Park, Jang-Ho;Yu, Yeong-Ho;Guk, Seung-Gi;Lee, Seo-Jeong;Park, Su-Hyeon;Jo, Seong-Cheol;Sim, U-Seong;Jeong, Min;Kim, Gyeong-Mi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.10a
    • /
    • pp.25-27
    • /
    • 2010
  • 국제해사기구(IMO) 제52차 NAV 회의에서 처음 소개된 e-Navigation은 그동안 국제항로표지협회(IALA), 국제수로기구(IHO), 국제통신연맹(ITU) 및 국제전기표준위원회(IEC)에서 많은 정책과 기술사항이 검토되어 왔다. 본 논문에서는 IALA e-NAV 제8차 기술위원회('10.9.20-24)에 참석하여 관련 국제기구에서 진행중인 e-Navigation 추진현황과 동향을 파악하여 앞으로 우리나라의 대응방향을 논하고자 한다.

  • PDF