• Title/Summary/Keyword: 기계부하

Search Result 701, Processing Time 0.026 seconds

Exergy-Based Performance Analysis of Heavy-duty Gas Turbine in Part-Load Operating Conditions (엑서지를 이용한 대형 발전용 가스터빈의 부분부하 성능 분석)

  • Song, T.W.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.751-758
    • /
    • 2001
  • Exergy concept is applied to the analysis of part-load performance of gas turbine engine. Exergy is a useful tool to find the source of irreversibility in thermal system. In this study, details of the performance characteristics of a heavy-duty gas turbine, l50MW-class GE 7FA model, are described by theoretical investigations with exergy analysis. Result shows that exergy destruction rate of gas turbine increases with decreased load, which means increase of irreversibility. Also, it is found that variations of IGV angle and amount of cooling air for turbine blades are closely related to the inefficiencies of compressor and turbine, respectively.

  • PDF

Temperature and Loading-Rate Dependence on the Mechanical Behavior of Carbon Nanotubes (탄소나노튜브의 역학적 거동에 관한 온도와 하중부하속도의 의존성)

  • Jeong Byeong-Woo;Lim Jang-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.7 s.250
    • /
    • pp.809-815
    • /
    • 2006
  • The temperature and loading-rate dependence on the mechanical behavior of single-walled carbon nanotubes under axial compression and torsion is examined with classical molecular dynamics simulation. The critical buckling is found to depend on the temperature and loading-rate. The yielding under torsion is also found to depend on the temperature and loading-rate. But it is shown that the compression and torsional stiffness are independent of the varied temperatures and loading-rates.

Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems (가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석)

  • 김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.

Analysis of Relationship Between Design and Part Load Performance of Gas Turbines (가스터빈의 설계 성능과 부분부하 성능 사이의 상관관계 분석)

  • Kim, Dong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1164-1171
    • /
    • 2002
  • This study analyzed the dependence of part load performance of simple cycle gas turbines on their design performance. Various parametric calculations were carried out to examine effects of design temperature ratio, pressure ratio and component efficiencies using a simplified analysis. In addition, a more practical analysis was done for realistic design conditions with the aid of a comprehensive performance analysis program. The results show that gas turbines with higher design performance exhibit less efficiency degradation during part load operation. The influence of power control method (fuel only centre) and air flow control) on part load performance was examined as well.

Influences of fuel additives on the low temperature reaction of DME HCCI engine (DME 예혼합압축착화 기관의 저온산화반응에 미치는 첨가연료의 영향)

  • Jung, Suk Ho;Ishida, Masahiro
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.19-23
    • /
    • 2012
  • DME HCCI기관의 단점은 디젤 엔진에 비해 기관부하 영역이 굉장히 좁다는 것이고 이는 저온산화반응이 너무 빨리 일어나서 노크를 발생시키기 때문이다. 저온산화반응을 억제하기 위해서 DME 연소에 미치는 천연가스의 영향을 실험한 결과, 천연가스가 DME의 저온산화반응을 억제시키기 때문에 기관부하영역이 확대된다는 것을 알았다. 본 연구에서는 서로 다른 세탄가를 가진 첨가연료가 DME 저온산화반응에 미치는 영향을 실험적으로 조사하였다. 그 결과 저온산화반응의 최고 열발생율은 세탄가에 의존하지 않지만 착화온도는 세탄가에 의존한다는 사실을 밝혔다.

Derating design approach of LED for reliability improvement (LED(Light Emitting Diode)의 부하경감 설계)

  • Kim, Byung-Nam;Kim, Jae-Jung;Kang, Weon-Chang;Son, Young-Kap;Chang, Seog-Weon;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1760-1765
    • /
    • 2007
  • This paper shows a derating design approach for LED reliability improvement. The LED is widely used in display devices or circuits. The main failure of interest is defined as 100% reduction of the light output intensity of LED resulting from corrosion due to stresses, i.e. temperature and humidity. The lifetime is varied according to the stress levels under where the LED operates so that correlation of the lifetime to these stress levels over time is modeled through accelerated life testings. A derating design approach to accomplish a required reliability level of LED is proposed to determine adequate the stress levels. In the approach, $B_{10}$ life, Failure rate, Sensitivity Analysis of LED are used as a reliability metric.

  • PDF

Storage of Heat Energy (熱에너지의 貯藏)

  • 노승탁
    • Journal of the KSME
    • /
    • v.18 no.4
    • /
    • pp.27-34
    • /
    • 1978
  • 열에너지의 저장시스템은 축열채조, 열전달기기와 용기 및 보온재의 3개 주요부로 이루어진다. 축열재료는 현열계의 경우 온도가 상승하거나 잠열이용의 경우 상변화가 생기는 재료를 말한다. 열전달기기는 열에너지를 열원으로부터 축열재로 건열시키거나 축열재로부터 열부하측으로 열에 너지를 전달시키는 역할을 한다. 보온이 된 용기는 축열재를 외부로부터 열차단이 되도록 하여 외부로의 에너지 손실이 없도록한다. 열에너지저장시스템의 주성능득성은 용량, 에너지전달원, 저장온도에 의하여 주어진다. 여기서 용량은 축열재가 저장할 수 있는 에너지의 양을 뜻하고 열 전달율은 에너지원으로부터 축열재료로 또는 반대로 축열재료로부터 에너지부하측으로 전달시킬 수 있는율을 의미한다. 축열온도는 현열계에서는 축열재의 온도가 된다. 이 해설에서는 최근 발간 된 수 개의 자료를 발췌하여 간략히 그 내용을 알리고자 한다.

  • PDF

A Method of ROL Improvement for the Motor Operated Gate Valve Operated in the High Differential Pressure Condition (고차압에서 운전되는 모터구동 게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Yoo, S.Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.1 s.28
    • /
    • pp.16-22
    • /
    • 2005
  • This paper presents the method of ROL(Rate Of Loading) improvement for the Motor Operated Gate Valve operated in high differential pressure condition. ROL is one of the most important evaluation parameters for the valve ability. It is close to correlation in stem factor (SF) and appears different value by the differential pressure of fluid. ROL and SF are analyzed by the static test and dynamic test. The obtained result show that the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of SF between static and dynamic test, stem and stem nut should be combined appropriately by the repetition test.

A Study on Full and Part Load Operations of a Biogas-fired Gas Turbine Combined Heat and Power System (바이오 가스를 사용하는 가스터빈 열병합 시스템의 전부하 및 부분부하 운전특성 해석)

  • Kang, Do-Won;Lee, Jong-Jun;Kim, Tong-Seop;Hur, Kwang-Beom
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2011
  • This study analyzed the influence of firing biogas on the performance and operation of a gas turbine combined heat and power (CHP) system. A reference CHP system designed with natural gas fuel was set up and off-design simulation was made to investigate the impact of firing biogas in the system. Changes in critical operating parameters such as compressor surge margin and turbine blade temperature caused by firing biogas were examined, and a couple of operating schemes to mitigate their changes were simulated. Part load operation of the biogas-fired system was compared with that of natural-gas fired system, and it was found that as long as the two system produce the same electric power output, they exhibit nearly the same heat recovery.

Modeling for the Work of Heart and Development of the WOH Medical device (심장운동부하 모델링과 의료장비 개발)

  • Roh, Hyung-Woon;Suh, Sang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.501-504
    • /
    • 2006
  • The estimation of the work of heart can be treated as one of the most important parameters for determining the amount of circulating blood needed for harmonious metabolism in the human body. By monitoring the work of heart, one can detect increased work load of heart and start the treatment at the early stage of CHF. Thus it is necessary to estimate the work of heart. The contractility of the left ventricle, the second important parameter for representing the motion of heart, can be estimated through information on the work of heart. In this study, the modified Windkessel model, which has been used for a measure of vascular hemodynamic impedance parameters, was adapted to estimate the work of heart.

  • PDF