• 제목/요약/키워드: 급탕설비

검색결과 120건 처리시간 0.023초

한국형 태양열 온수급탕 시스템의 제안 (Proposal for Korean Solar Water Heating System)

  • 최봉수;윤두한;김성수;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.105-110
    • /
    • 2006
  • Several types of solar water heating system were analyzed in characteristics and proper systems were proposed under Korean climates. In particular, the forced circulation type with a spiral-jacketed storage tank has a potential to be used widely in a small and a part of middle systems when the stratification of the storage tank can be enhanced by a precise design.

  • PDF

공동주택용 태양열원 급탕시스템의 운전성능 연구 (A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses)

  • 이윤규;황인주
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

아파트에서의 적정 급수.급탕량 산정법 (Estimating of reasonable amount of cold and hot water supplied in an apartment house)

  • 김석중;김성남
    • 대한설비공학회지:설비저널
    • /
    • 제28권4호
    • /
    • pp.276-289
    • /
    • 1999
  • 최근 들어, 생활수준의 향상과 인구의 증가로 인하여 서울 주변에는 위성도시가 건설되고 이러한 위성도시의 완성으로 공동주거(아파트)의 관심은 날로 높아져 가며, 생활양식의 변화로 인하여 건축물에서 생활용수의 사용량이 급격히 증가하고 있다.

  • PDF

LCC기법을 통한 교육시설물의 유지관리비 변동범위 분석 (Variation Range for Maintenance Costs of Education Facilities Based on LCC Analysis)

  • 김용수;강현욱
    • 한국건설관리학회논문집
    • /
    • 제11권3호
    • /
    • pp.72-79
    • /
    • 2010
  • 본 연구는 교육 시설물의 부위별(건물외부, 건물내부, 전기소화설비, 급수위생설비, 난방급탕설비) 유지관리비 변동범위 분석을 목적으로 수행되었다. 이를 위해 경기도에 위치한 10년 이상 운영되고 있는 교육시설물 3곳을 사례대상으로 선정한 후 보수이력에 따른 유지관리비 지출 내역을 조사하였다. 이렇게 조사된 실행 유지관리비와 LCC 기법을 통해 분석된 추정 유지관리비의 비교를 통해 변동범위를 분석하였다. 유지관리비의 변동범위 분석은 확률적 기법인 몬테카를로 시뮬레이션을 활용하였다. 상기와 같은 목적과 방법에 의해 분석된 결론을 요약하면 다음과 같다. 첫째, 사례 3곳의 부위별 평균 실행 유지관리비 분석 결과 총액 1,317백만원 대비 건물외부 19%, 건물내부 28%, 전기소화설비 22%, 급수위생설비 18%, 난방급탕설비 13%로 분석되었다. 둘째, 사례 3곳의 부위별 평균 추정 유지관리비 분석 결과 총액 1,920백만원 대비 건물외부 20%, 건물내부 25%, 전기소화설비 22%, 급수위생설비 20%, 난방급탕설비 13%로 분석되었다. 셋째, 사례 3곳의 부위별 실행 유지관리비 평균과 추정 유지관리비 평균에 대한 변동범위 분석 결과 평균 1,619백만원, 최소 1,409백만원, 최대 1,813백만원으로 분석되었다.

법령과 고시 - 친환경 주택 건설기준 및 성능 고시

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권233호
    • /
    • pp.55-57
    • /
    • 2009
  • 국토해양부는 지난 10월 20일 20가구 이상의 공동주택을 건설할 경우 총에너지를 종전보다 10~15% 이상 절감토록 하는 내용의 '친환경 주택의 건설기준 및 성능'을 고시하고 이날부터 시행에 들어갔다. 국토부는 친환경적인 주택 건설을 위한 제도적 기반을 구축하기 위해 에너지 소비절감 및 탄소배출량 감소를 위한 에너지절약형 친환경 주택의 건설기준 및 성능을 마련한 것이다. 이 고시는 친환경 주택으로 인정받기 위한 필수시설 및 각각의 설치기준 제시와 에너지 사용용도에 따라 난방, 급탕, 전력, 열원 등 4개로 분류하는 친환경주택 성능 평가방법 등을 규정했다.

  • PDF

아파트 난방 통합시스템 개발-변산건설(주), '열병합발전과 개별난방 통합 시스템' 특허 획득

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 8호통권205호
    • /
    • pp.49-52
    • /
    • 2007
  • 벽산건설(주)은 최근 '열병합발전과 개별난방 통합 시스템’을 개발, 특허를 획득했다. 이 기술은 아파트에 소형 열병합발전기를 설치하는 중앙난방방식과 기존 개별난방방식이 합쳐진 통합 시스템 이다. 이 시스템은 열병합발전 시스템과 개별난방 시스템을 동시에 실시, 열병합발전에서 발생하는 폐열을 이용해 급탕수 온도를 높여 이를 직접 배출시키거나 개별보일러로 공급해 개별보일러의 연료 소모량을 절감토록 한 것이다. 벽산건설(주)이 개발한 '열병합발전과 개별난방 통합 시스템’에 대해 살펴본다.

  • PDF

$CO_2$ 급탕 열펌프의 성능 특성에 관한 실험적 연구 (Experimental Study on the Performance of a $CO_2$ Heat Pump Water Heater)

  • 이응찬;백창현;강훈;김용찬;조홍현;조성욱
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.367-372
    • /
    • 2009
  • The performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, outdoor temperature, compressor frequency, EEV opening, and water mass flow rate. The optimum refrigerant charge amount of the $CO_2$ system was 1800 g. At water mass flow rates of 75, 85, and 95 kg/h, the water heating temperatures were 74, 67, and $62^{\circ}C$ and COPs were 2.6, 2.8, and 3.0, respectively. Besides, the compressor frequency and water mass flow rate were adjusted to maintain the water heating temperature at $60^{\circ}C$ with the decrease of outdoor temperature. As the outdoor temperature decreased by $5^{\circ}C$, the compressor frequency increased beyond 60 Hz and the water mass flow rate decreased by 16.7%.

이산화탄소 급탕 열펌프의 난방 성능에 관한 실험적 연구 (Experimental Study on the Heating Performance of a $CO_2$ Heat Pump Water Heater)

  • 백창현;이응찬;강훈;김용찬;조홍현;조성욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.310-315
    • /
    • 2008
  • In this study, experimental study on the heating performance of a $CO_2$ heat pump water heater with a variation of operating conditions such as refrigerant charge amount, outdoor temperature, compressor frequency, EEV opening and water mass flow rate. Based on the test results, the optimum charge amount was 1800 g. At the water mass flow rates of 75, 85, 95 kg/hr, the water heating temperature was 62, 67, $74^{\circ}C$ and COP was 2.6, 2.8, 3.0, respectively. Besides, the water mass flow rate and compressor frequency were varied to maintain above the water heating temperature of $60^{\circ}C$ with the decrease of outdoor temperature. So, The compressor frequency increased beyond 65 Hz and the water mass flow rate was 45 kg/hr at the outdoor temperature of $-13^{\circ}C$, 65 kg/hr at $-8^{\circ}C$, 75 kg/hr at $-3^{\circ}C$ and 85 kg/hr at 2, $7^{\circ}C$. As the outdoor temperature decreased, the heating COP decreased by 2.5-39.8%.

  • PDF

지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링 (LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System)

  • 박영칠
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.