• Title/Summary/Keyword: 급전소

Search Result 46, Processing Time 0.028 seconds

Electromagnetic Induction Voltage according to the Position of Telecommunication Line from the Power Feeding Plant of Electrified Railway System (전기철도의 급전소 위치 관계에 따른 통신선 전자유도 전압)

  • Lee, Sangmu;Choi, Munhwan;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.689-692
    • /
    • 2015
  • That induced voltage by an electrified railway line is related with the position of telecommunication line between traction power feeding systems is practically varified by measurements in the real field. This experimented fact is conformed with the calculated simulation provided by the ITU-T Directives concerning the protection of telecommunication lines against harmful effects from electric power and electrified railway lines. Therefore it is needed to consider at what position a telecommunication line is parallelized with power feeding line of traction system when an induction phenomenon is evaluated or measurement is carried out besides the length of parallelization and the separate distance between power line and telecommunication line.

  • PDF

A Control Method of Phase Angle Regulator for Parallel-Feeding Operation of AC Traction Power Supply System (교류전기철도 병렬급전 운영을 위한 위상조정장치 제어기법)

  • Lee, Byung Bok;Choi, Kyu Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.672-678
    • /
    • 2020
  • The parallel-feeding operation of an AC traction power supply system has the advantages of extending the power supply section and increasing the power supply capacity by reducing the voltage drop and peak demand caused by a train operation load. On the other hand, the parallel-feeding operation is restricted because of the circulating power flow induced from the phase difference between substations. Moreover, the power supply capacity is limited because of the unbalanced substation load depending on the trainload distribution, which can be changed by the train operation along the railway track. This paper suggests a Thyristor-controlled Phase Angle Regulator (TCPAR) to reduce the circulating power flow and the unbalanced substation load, which depends on the phase difference and the trainload distribution and provides a feasibility study. A dedicated control model of TCPAR is also provided, which uses substation power supplies as the input to control the circulating power flow and an unbalanced substation load depending on the phase difference and the trainload distribution. Simulation studies using PSCAD/EMTDC shows that the proposed TCPAR control model can reduce the circulating power flow and the unbalanced substation load depending on the phase difference and the trainload distribution. The proposed TCPAR can extend the parallel-feeding operation of an AC traction power system and increase the power supply capacity.

Analysis on the induction effects by electricity feeder station of the electromagnetic induction from high-speed railway system (고속전철 전자유도에 대한 급전소 유도 효과 실측연구)

  • Han, Man-Dae;Choi, Mun-hwan;Lee, Sang-mu;Cho, Pyoung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.843-846
    • /
    • 2009
  • 경부고속전철의 급전선에 의한 전력유도 대책을 위하여 건설 당시 정보통신부 고시에 의하여 시행되었다. 통신선에 장애를 유발할 수 있는 전자유도 대책을 위해서는 국가 기술기준에 의한 유도전압 한계치가 정해져 있고 현장 대책 상 이 제한치를 초과할 때에 필요한 것이므로 상기 정부 고시의 기술 근거에 의해 유도전압을 계산하여 조치하고 있다. 전기철도시스템에서 지역 구간상의 전력 공급을 위한 일정 거리마다 급전소가 시설되어 있어서 이로부터 전철에 전력이 공급되고 있다. 전철의 유도현상에 의한 유도전압 분포 분석을 위한 전국 구간 유도측정을 수행하여 급전구간에서의 유도전압 특성을 파악하였다. 구간 중심점상에서 낮아지는 전압에 대해 급전소 근접 구간에 이르렀을 때의 전압 상승 특성을 분석하였다. 급전소로부터 귀로되는 전류의 양이 집합됨으로 유도전압이 높아지고 거리가 멀어질수록 전압은 떨어진다. 유도대책을 전압 분석에 있어서와 차폐시설물의 연계 활용 시 이러한 전압의 영향성을 고려할 필요가 있다.

  • PDF

Analysis on an Inducing Current Change between Railway Power Feeding Plants (전기철도 전자기 유도 전류의 급전구간 상대적 위치 관계에 따른 변화 분석)

  • Lee, Sangmu;Choi, Mun Hwan;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.567-569
    • /
    • 2012
  • An inducing current of power feeding line of high-speed railway system is varied by a relative position of telecommunication cable to the feeding line between plants. An analytical calculation formula of this inducing current is described in ITU-T Directives using multiconductor line method or two line method. In this paper, using the two line method, a variation characteristic of inducing current is simulated. The inducing current has a characteristic of hyperbolic function which is a symmetric shape of curve in the range between power feeding plants. This basic variation property can be considered when a power induction protection measure is planned.

  • PDF

Analysis on the Induction Effects by Separation Distance between the Power Feeding Station and the Telecommunication Cables (고속전철 급전소와의 이격거리에 따른 전력 유도 영향 분석)

  • Choi, Mun-hwan;Lee, Snag-mu;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.573-576
    • /
    • 2012
  • We have analyzed the induction effects by separation distance between the power feeding station and the telecommunication cables. To do this we measured the induced voltage in 11 sections(10km) between Jangseong and Imgok at Jeon-nam province using telecommunication cable installed nearby KTX's feeder line. Sub-section has about 1km length of telecommunication cable. And we used normalization method in installed length of telecommunication cables and mutual inductance to analysis the induction effects more rationally.

  • PDF

세계 각국의 전력계통제어소 소개 1

  • 윤갑구
    • 전기의세계
    • /
    • v.29 no.9
    • /
    • pp.545-550
    • /
    • 1980
  • 본고의 내용은 다음과 같다. 1. 급전소의 기본적 기능 2. 급전소의 필요한 설비 3. 원격통신계통에 대한 계획 4. 원격측정계통 계획 5. 자료처리설비 계획

  • PDF

An Algorithm to Analyze Rail Potential Rise in DC Traction Power Supply System (레일전위상승 분석을 위한 컴퓨터 알고리즘)

  • Chung, Sang-Gi;Kim, Hyung-Chul;Jung, Ho-Sung;Kwon, Sam-Young
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.687-693
    • /
    • 2009
  • An algorithm and a computer software are developed for the analysis of rail potential rise. The algorithm is intended to be integrated with the traction power system simulation program. In the algorithm, rail potentials are obtained by two step process. First the injection currents to the negative rail are obtained from load-flow study. In the next step, a network consisting of negative rail and the injection currents are constructed. Leakage resistance to ground are added to the network. And the network is analyzed for rail potentials. A software is developed to verify the validity of the algorithm. The result of the software is compared with the Simulink/SymPower circuit analysis result. The differences between the two results are with the acceptable range. The advantage of this algorithm is that it can be integrated with the existing traction power supply simulation program easily, which usually ignores negative rail's leakage resistance.

세계각국의 전력계통 제어소 소개

  • 윤갑구;이희성
    • 전기의세계
    • /
    • v.31 no.11
    • /
    • pp.766-770
    • /
    • 1982
  • 본고의 내용은 다음과 같다. 1. 전력계통의 개요 2. 급전시스템의 개요 3. 여섯번째 설립한 컴퓨터제어 시스템 4. 신 제어소 5. 원격소의 설비

  • PDF

Modeling DC Electric Railway System using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 직류 급전 시스템 모델링)

  • Choi, Joon-Ho;Lee, Han-Min;Choi, Jong-Ook;Jang, Gil-Soo;Oh, Kwang-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.290-292
    • /
    • 2002
  • 전기철도 급전계통은 차량 또한 이동 부하이고, 비정상적인 전기적 특성이 나타날 수 있으므로, 전기적으로 정확한 해석을 할 필요가 있다. 본 연구는 PSCAD/EMTDC 과도해석 프로그램을 이용하여 직류 전기 철도 시스템을 모델링 함으로써 전기철도 급전계통의 정확한 특성을 연구하는 것이다. 한전 계통으로부터 전력을 급전 받아 전기철도차량 부하에 공급되는 급전계통을 실제와 가깝게 모델링 함으로써 정상상태 해석과 사고 시 과도특성 분석 및 계통에의 영향 해석을 목적으로 한다. 프로그램 특성상 각각의 소자를 모델링 한 후 4단자망 이론에 근거, 각 소자를 결합하여 전체 계통을 구성한다. 각각의 소자는 전차선로, 정류기 및 제어기를 포함한 차량부 (전동기, 제어소자), 정류 변전소 등으로 구성된다. 이 논문에서는 급전계통의 정상상태 및 고장전류를 분석함으로서 제안된 모델을 검증한다.

  • PDF

The Analysis Transient Characteristic at Short-Circuit in AT Feeder System using EMTDC (EMTDC를 이용한 AT 급전시스템 단락사고시 과도특성 분석)

  • Lee, Hwan;Bae, Jong-Il;Kim, Yang-Su;Lee, Gi-Sik;Kim, Jae-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1583-1584
    • /
    • 2015
  • 최근 철도차량의 고속화와 전력회생을 하는 전기차로 인하여 부하전류와 고장전류 간의 큰 차이가 없으므로 이를 구분할 수 있는 고성능 보호시스템의 중요성이 날로 증대되고 있다. 본 논문은 실계통에서의 전차선로 임피던스를 이용하여 AT급전시스템을 모델링하였으며 변전소와 보조급전구분소사이 단락사고의 과도특성을 분석하였다.

  • PDF