• Title/Summary/Keyword: 급수링

Search Result 89, Processing Time 0.027 seconds

Prediction of Internal Tube Bundle Failure in High Pressure Feedwater Heater for a Power Generation Boiler by the Operating Record Monitoring (운전기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손예측)

  • Kim, Kyeong-seob;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.2
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, the failure analysis of the internal tube occurred in the high pressure feedwater heater for power generation boiler of 500 MW supercritical pressure coal fired power plant was investigated. I suggested a prediction model that can diagnose internal tube failure by changing the position of level control valve on the shell side and the suction flow rate of the boiler feedwater pump. The suggested prediction model is demonstrated through additional cases of feedwater system unbalance. The simultaneous comparison of the shell side level control valve position and the suction flow rate of the boiler feedwater pump compared to the normal operating state value, even in the case of the high pressure feedwater heater for the power boiler, It can be a powerful prediction diagnosis.

A Stress Analysis of Wall-Thinned Feedwater Ring in Nuclear Power Plant (원전 증기발생기 감육 급수링 응력해석)

  • Min Ki Cho;Ki Hyun Cho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.56-63
    • /
    • 2021
  • The feedwater ring is an assembly in steam generator internal piping, which distributes feedwater into the secondary side of the steam generator. It consists of an assembly of carbon steel piping, pipe fittings and J-nozzles which are inserted into the top of the feedwater ring and welded to the diameter of the ring. The feedwater ring at the attachment region of the J-nozzle may be susceptible to flow accelerated corrosion (FAC) due to flow turbulence which increases local fluid velocities. If a J-nozzle becomes a loose part, it can cause damage to tubing near the tube sheet. In this paper, the structural stress analysis for a wall thinned feedwater ring and integrity evaluations under assumed loading conditions are carried out in compliance with ASME B&PV SecIII, NB-3200.

Analysis of Burst Detection Based on Adjustable Sampling Interval (가변적 샘플링 기반한 누수탐지 분석)

  • Kim, Seong Won;Jeong, An Chul;Jung, Kwan Sue
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.292-292
    • /
    • 2015
  • 최근 상수관망의 물 공급 과정에서 여러 가지 원인으로 인해 물의 손실에 따른 비용손실이 발생하고 있다. 급수시스템의 경우에는 파열 및 누수발생과 관련되어 사용되는 비용은 분실되는 물의 직적비용, 급수시스템 수리에 따른 공사비용, 공급중지와 관련된 사회적 비용이 있다. 파열 및 누수를 신속하게 감지하는 것은 물 손실에 의해 발생하는 직접 및 간접비용을 줄일 수 있다. 그러나 국내의 경우 정기적으로 매년 1회 시행되는 상수관로에 대한 누수탐지작업으로 신속한 감지 및 즉각적인 대처를 할 수 없는 실정이다. 본 연구에서는 수도관에서 발생되는 파열 및 누수를 탐지하기 위하여 블록 유입부에 설치된 유량계의 샘플링 간격의 영향에 대한 연구를 실시하였다. 적응칼만필터 알고리즘을 이용한 가변 샘플링 간격은 최대 최소 샘플링 간격과 정규화된 잔차의 상한값과 하한값 도입하여 제시하였다. 샘플링 간격의 효과를 강조하기 위해 사인 곡선, 사다리꼴 파열, 불규칙 잡음으로 구성된 가상의 유량 데이터로 알고리즘에 대한 검증실험을 진행하였고 실험 결과 샘플링 간격이 길수록 긴 시간 동안 누수 및 파열에 대한 작은 잔차를 발생시켰다. 모의실험결과 샘플링 주기를 변경함으로써 분석에 필요한 유량 데이터의 샘플수를 크게 줄일 수 있었다.

  • PDF

Study on Cause and Effect of SG Feed Water Ring Through-Wall Hole (증기발생기 급수링 관통손상 원인 및 영향 고찰)

  • Lee, Sung Ho;Lee, Yo Seob
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.61-68
    • /
    • 2015
  • The function of Feed Water Ring is to provide the flow path from Feedwater Nozzle to inside of SG(steam generator). Significant amounts of general FAC on the outside of the Feed Water Ring are not likely due to the low flow velocities in this area. However, on the interior of the Feed Water Ring, there may be areas of local higher flow velocity which could lead to higher FAC rates. These may include the inlet tee from the Feedwater Nozzle into the Feed Water Ring, the areas where the Feed Water Ring changes diameter, and especially the entrance area to the J-Nozzles. In this paper, the results of root cause analysis of through-wall hole observed at domestic WH 51F SG Feed Water Ring and its effect on the integrity and performance of SG are described. And, the maintenance strategy for WH 51F SG Feed Water Ring and the monitoring strategy for Downcomer Feed Water Ring of CE System 80 SG are presented.

Development of groundwater level monitoring and forecasting technique for drought early warning (가뭄 예·경보를 위한 지하수위 모니터링 및 예측기법 개발)

  • Lee, Jeongju;Kim, Taeho;Chun, Genil;Kim, Hyeonsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.13-13
    • /
    • 2020
  • '20년 3월 현재 전국 3,502개 읍면동 중 73개 읍면동이 지하수를 상수원으로 급수 중이며, 48개 산업단지에서 지하수를 주 수원으로 사용 중이다. 또한 급수 소외지역의 물 공급을 위해 주로 사용되는 소규모수도시설 14,811개 중 12,073개(81.5%)는 지하수를 이용하고 있으며, 그 위치는 전국에 산재해 있다. 이처럼 지하수는 댐, 저수지 및 하천과 더불어 생·공용수의 중요한 수원이라 할 수 있다. 본 연구에서는 급수 소외지역의 주요 수원인 지하수위 현황을 이용한 가뭄 모니터링 및 전망 기법을 개발하고자 하였다. 국가 지하수관측망 중 10년 이상 장기 관측 자료를 보유한 253개 관측소의 일단위 관측자료를 기반으로, 과거 관측수위 분포를 핵밀도함수로 추정하고 Quantile Function을 이용해 현재 수위의 높고 낮은 정도를 Percentile 값으로 산정하였다. 관측소별 지하수위 Percentile은 티센망을 이용해 167개 시군별로 공간평균하고 Percentile의 범위에 따른 가뭄등급을 설정하여 지하수 가뭄 정도를 모니터링 할 수 있는 기법을 제시하였다. 또한 지하수 가뭄을 전망하기 위해 강수와 지하수위의 거시적인 응답특성을 이용하였다. 관측소별로 추정된 핵밀도함수의 누적확률을 표준정규분포의 Quantile로 변환하여 표준지하수지수I(Standardized Groundwater level Index, SGI)를 산정하고, 시군별로 공간을 일치시킨 1~12개월 지속기간별 표준강수지수(Standardized Precipitation Index, SPI)와의 상관관계를 이용해 NARX(nonlinear autoregressive exogenous) 인공신경망 예측모형을 구축하였다. 이를 통해 기상청 정량전망 강수량을 이용해 전국의 1~3개월 후 지하수 가뭄을 빠르게 전망할 수 있는 체계를 구축하고, 생·공용수 분야 국가 가뭄 예·경보의 미급수지역 가뭄현황 및 전망에 활용중이다.

  • PDF

Characteristics of Heat Recovery Rate and Fouling according to Structures and Materials in Heat Exchangers (열교환장치의 구조 및 재질에 따른 열회수율과 파울링의 발생 특성)

  • Kim, Hyun-Sang;Kim, Yong-Gu;Bong, Choon-Keun;Lee, Myong-Hwa
    • Resources Recycling
    • /
    • v.24 no.2
    • /
    • pp.3-12
    • /
    • 2015
  • We researched characteristics of heat recovery rate and fouling according to structures and materials in heat exchangers like water preheater and air preheater. Economizer and air preheater have used in thermal electric power plant. we made small incinerator and heat exchangers to carry out simulated experiment. We observed fouling formation and change of heat recovery rate, combusting powdered coal for 24 hr. In economizer, fin tube type had the largest amount of fouling formation, followed by tube line type > pipe type > auto washing type according to structures. As heat recovery rate, fin tube showed highest recovery rate, followed by auto washing type > pipe type > tube line type. In air preheater, fin tube type had the largest amount of fouling formation, followed by fin plate type > pipe type > pipe type coated by teflon > pipe type coated by ceramic according to structures. And then, heat recovery rate showed the same oder.

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Development and Application for Stable Technology Agricultural Water Management in Recurrent Drought Areas of Geum River Basin (금강권역 상습 가뭄지역의 안정적인 농업용수 공급관리 기술 개발 및 적용)

  • Kim, Da Ye;Hong, Eun Bi;Maeng, Seung Jin;Lee, Gwang Ya;Park, Ji Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.74-74
    • /
    • 2021
  • 우리나라의 농업용수 사용량은 152억톤으로 우리나라 전체 물 사용량의 약 42%이며, 농업용수의 관리는 전체 논 면적 865천ha 중 한국농어촌공사에서 487천ha(56%), 지방자치단체에서 221천 ha(26%), 수리 불안전답이 157천ha(18%)이다. 또한 우리나라에 설치된 저수지, 양수장 등과 용수로로 공급되는 농업용수 공급량 중 논에 유입되지 못하고 퇴수되는 물이 약 43%이다. 농업용수 급수 중 용수로의 수위가 낮아 급수관을 통해 논에 유입되지 못하고 배수로로 퇴수되고 있는 실정이다. 농업용수 급수가 원활하기 위해서는 용수로의 수위를 20cm이상 확보하여야 급수관을 통해 논에 급수가 가능하다. 하지만 현장에서는 이러한 물 공급의 문제점을 해결하기 위해 용수로를 비료포대 등으로 막아서 사용함으로써 용수로 시설물의 관리가 되지 않고 토사가 쌓여 급수 애로가 가중되는 상황으로 시설물 관리를 위한 용수로 준설 등 시설 유지관리비가 발생하고 있다. 특히 금강권역(금강, 만경강, 동진강, 삽교천, 충남 서북부)에서 상습적인 가뭄 발생으로 농업용수 사용에 관한 분쟁이 상시적으로 도사리고 있는 실정이다. 이러한 문제를 해결하기 위해 농업용수의 급수 손실을 최소화하며 원활하고 안정적인 용수를 공급하고자 하였으며, 농민을 대상으로 설문지를 작성하여 응답을 분석하고 농민들의 요구사항을 개선하기 위해 법·제도, 거버넌스, 재원 및 기술·시설로 구분하여 제시하였다. 또한 과거 관행에 의한 유말부 용수공급에 탈피해서 원활한 용수공급이 가능하고 유지관리가 쉬운 장치인 부력식 제수문을 선정하고 제시하였다. 따라서 본 연구에서는 금강권역 상습 가뭄지역의 안정적인 농업용수의 공급관리를 위한 기술 개발 및 적용을 실시하고, 농업용수 공급관련 정량화된 손실현황을 분석한 후 수위확보 장치 적용 전·후 모니터링으로 효과 분석을 실시하였다.

  • PDF

The LQG/LTR Dynamic Digital Control System Design for the Nuclear Steam Generator Water Level (증기발생기 디지탈 수위조절 시스템의 LQG / LTR 동적 제어설계)

  • Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.730-742
    • /
    • 1995
  • The steam generator feedwater and level control system is designed by two steps of the feedwater control design and the feedback loop controller design. The feedwater sen system is designed by the optimal LQR/LQG approach and then is modified by the LTR method to recover the robustness. The plant characteristics are subject to change with the power variation and these dynamic properties are considered in the design of the feedback controller. All the designs are made in the continuous domain and are digitalized by applying the proper sampling period. The system is simulated for the two cases of power increase and decrease. From the results of simulation, it is found that the controller constants would rather be invariable during the power increase, while for the case of power decrease they should be changed with the power variation to keep the system stability.

  • PDF

Expanded Tag-based Collaborative Filtering Approach (확장된 태그 기반 협력적 필터링)

  • Shin, Dong-Min;Lee, Jae-Won;Lee, Kyeong-Jong;Lee, Sang-Goo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06c
    • /
    • pp.91-94
    • /
    • 2008
  • 정보 기술의 발전으로 인해 이용할 수 있는 정보가 기하급수적으로 늘어남에 따라, 사용자는 원하는 정보를 얻는 데 어려움을 겪게 되고, 양질의 정보를 찾기 위해 많은 시간을 들이고 있다. 이에 사용자의 의도를 정확하고 명백하게 드러내는 태그 정보에 기반한 협력적 필터링 기법을 이용하여 사용자가 원하는 적절한 음악을 추천하는 시스템을 제안하며, 태그의 확장을 통한 협력적 필터링 기법의 성능 향상을 제안한다.

  • PDF