• Title/Summary/Keyword: 급기량

Search Result 51, Processing Time 0.032 seconds

Hardware configuration of High-Density HVPS and High Speed independent Control method Using FPGA for Phased Array Transmitters (위상 배열 고출력증폭기용 고밀도 고전압 전원공급기 하드웨어 구성 및 FPGA를 이용한 고속 독립 제어방식)

  • Kang, Chun-Ho;Lee, Sung-Wook;Lee, Hong-Hak;Lee, Chang-Hoon;Byun, Gi-Sig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2758-2764
    • /
    • 2015
  • In the field of electronic warfare applications, high voltage power supply(HVPS) for high power phased array transmitters must necessarily have an independent operating characteristics for driving mini TWTs. TWT independent operational characteristics, in order to run without interrupting the electronic warfare mission by maintaining the partial transmission function even when one of the TWT has occurred a failure, is known to be very important. In this paper, we describe the research on high-speed independent control system using a high-density HVPS, including FE modulators, hardware configuration and the FPGA in order to independently operate mini TWTs. Also, we have simulated some possible faults in phased array transmitters, and presents the test results to control a faulted TWT independently.

Hydrogen Storage Using Nano-Materials (나노 물질을 이용한 수소 저장)

  • Yu, H.Y.;Kim, B.H.;Oh, S.Y.;Yun, Y.J.
    • Electronics and Telecommunications Trends
    • /
    • v.23 no.6
    • /
    • pp.38-47
    • /
    • 2008
  • 지구상에 존재하는 화석연료는 산업혁명 이후 그 사용에 있어서 지속적인 증가 추세를 유지하여 왔고, 급기야는 그 잔존량의 고갈 및 이들 연료의 사용으로 인한 지구의 대기오염 등을 유발하고 있다. 이에 따라 새로운 에너지원, 즉 태양 에너지, 수소 에너지, 바이오 에너지 등에 그 활용 시각이 돌려지게 되었으며 이들은 다음 세대의 전인류적 에너지원으로 활용될 가능성이 원유 가격의 상승에 따라 점점 높아지고 있다. 이들 대체 에너지 중에서 수소 에너지는 지구뿐만 아니라 우주적으로 현존량이 가장 많은 에너지로 알려져 왔으며 이러한 수소 에너지 활성화를 위하여 무엇보다도 중요한 것이 수소 저장 능력에 관한 것이다. 본 분석에서는 이러한 수소 에너지를 비롯한 수소 저장에 대한 내용을 다루고 있으며 앞으로의 수소 저장 방향에 대해서 또한 언급한다.

진공챔버 내부의 위성표면온도 제어용 비접촉 적외선 발열장치 개발

  • Jo, Hyeok-Jin;Seo, Hui-Jun;Lee, Sang-Hun;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.49-49
    • /
    • 2010
  • 본 논문은 진공챔버 내부에서 위성 표면의 온도를 제어하기 위한 할로겐램프를 이용한 적외선 발열장치의 개발에 관한 것으로, 인공위성이 우주궤도에서 받게 되는 복사에너지를 지상의 진공챔버 내에서 모사하기 위한 비접촉 적외선 발열장치에 관한 것이다. 진공챔버 내에서의 비접촉식 발열 방법 중, 진공환경에서의 오염을 발생시키지 않고, 발열 시간 및 냉각 시간이 가장 짧으며, 높은 열효율로 태양복사에너지를 가장 근사하게 모사할 수 있는 할로겐 램프를 이용한 발열 방법을 적용하였으며, 램프에서 방사되는 열에너지가 위성표면에 균일하게 분포될 수 있도록 위성 표면으로부터의 거리와 램프의 개수, 램프의 배열에 따른 에너지 분포 계산식을 도출하여 적용하였다. 공급 전압에 따른 램프의 저항특성을 파악하여, 원격으로 제어되는 150 VDC, 5 A의 직류전원공급기를 이용해 램프의 발열량을 조절하였으며, 발열량에 따른 위성 표면온도에 대한 해석을 수행하였다. 램프를 이용한 비접촉식 적외선 발열장치 개발을 통해 진공환경에서의 시험대상에 대한 효율적인 열에너지 부과방법 수립이 가능하였다.

  • PDF

Design of Electrolysis Reactor for the Reclamation System (중수도 시스템 운전을 위한 전기분해장치의 설계)

  • Sin, Chun-Hwan;Bae, Jeong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.323-327
    • /
    • 2006
  • 전류밀도를 $1.0\;A/dm^2{\ell}$로 고정시키고, 촉매로 사용된 소금의 농도를 전체 폐수량의 약 15%로 조절하여 접촉시간을 $0\;{\sim}\;120$ 분으로 조절하여 각각의 시간에서 $COD_{Mn}$ 농도 약 70mg/L의 합성폐수를 전기분해 처리하여 접촉시간 약 30분에서 약 25 mg/L로 제거 되었으며, 60분이 지난 후부터 약 12 mg/L로 제거되는 것을 확인 할 수 있었다. 접촉시간을 1 시간으로 고정시키고, 촉매로 사용된 소금의 농도를 전체 폐수량의 약 15%로 조절하여 전류밀도를 $0\;{\sim}\;2.0\;A/dm^2{\ell}$로 조절하여 각각의 전류밀도에서 $COD_{Mn}$의 농도변화 실험결과 전류밀도 약 1.0 $A/dm^2{\ell}$에서 약 9 mg/L로 제거가 가능한 것으로 조사 되었다. 접촉시간을 1 시간, 전류밀도를 $1.0A/dm^2{\ell}$로 고정시키고 사용된 소금의 농도를 전체 폐수량의 $0\;{\sim}\;30\;%$로 조절하여 각각의 촉매 첨가율에서 $COD_{Mn}$의 농도변화를 조사결과 촉매 첨가율 30 %에서 가장 높은 처리효율을 나타내었으며, 촉매의 첨가에 의한 전기분해 효율뿐만이 아니라 직류전원공급기에 전기적 부하 또한 감소되는 것을 확인 할 수 있었다.

  • PDF

A Study on the Performance of Ondol with a Ventilation System (환기시스템을 갖춘 온돌 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4047-4051
    • /
    • 2014
  • Modern apartment houses are constructed to be relatively airtight with a high heat insulation system to increase the energy efficiency. Such a system has a range of deleterious effects due to the insufficient ventilation. In this study, the ondol system, which is used as a heat source typical of winter in Korea, was set as the default system to evaluate the indoor heat environment according to the ventilation method, the factors of energy reduction by the ventilation system was analyzed. The experimental apparatus was used to simulate the ambient conditions for a certain constant temperature and humidity chamber. The experimental results showed that the supply water temperature higher air volume decreases with increasing supply air temperature in the following order: floor supply/exhaust > total heat exchange supply/exhaust > forced supply/exhaust. Through this study, the applicability of various ventilations could be examined.

Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System (특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구)

  • Lee, Su-Kyung;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.85-90
    • /
    • 2011
  • This study of the vestibule of pressurizing smoke control system installed in domestic high-rise buildings for evacuation in case of fire, when the door is open to forming characteristics of the air flow was analyzed using fire dynamics simulator and analyzed of variance. Vestibule which is compartment of the design condition, air flow in the exhaust damper was formed severe turbulence confirming preceding research. The door position is in the range of formed vortex, unsteady flow of air occurs at the point that the door could be confirmed. According to the NFSC 501A, door to symmetrically separate the average of 10 points or more as measured from the average of wind speed to do is based. Under these conditions, it is difficult to measure the characteristics of the upper air flow of upper points. so measuring points are subdivided by more than 64 points method presented in TAB because severe deviation of wind speed.

The Experimental Study on the Leakage of Automatic Pressure Differential · Overpressure Control Dampers (자동차압 · 과압조절형댐퍼의 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.71-75
    • /
    • 2015
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of 40 Pa~60 Pa, but pressure differential is over 60 Pa in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by testing for identifying this problems. The result of testing, leakage is $0.090m^3/s{\sim}0.154m^3/s$. It is necessary to limit the leakage of dampers for safe of escapers.

Analysis of Cooling Air Current and Efficiency of Air Conditioning in the Underground Subway Station with Screen-Door Opening and Closing (도시철도 역사 스크린 도어 개폐에 따른 냉방 기류 해석 및 효율 비교 분석)

  • Jang, Yong-Jun;Ryu, Ji-Min;Jung, Ho-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.328-335
    • /
    • 2014
  • Numerical prediction methods were applied to investigate the turbulent air currents and air-conditioning efficiency in an underground subway station, and the results compared to experimental data. The Shin-gumho Station($8^{th}$ floor underground and 43.6m in depth) in Seoul was selected for the analysis. The entire station was covered for simulation and the ventilation mode was ordinary. The ventilation diffusers were modeled as 95 square shapes of $0.6m{\times}0.6m$ in the lobby and as 222 square shapes in the platform. Cooling air of $47,316m^3/h$ was supplied and the returned air of $33,980m^3/h$ is exhausted in the lobby and the cooling air of $33,968m^3/h$ is supplied and the returned air of $76,190m^3/h$ was exhausted in the platform which is the same as the experimental data. The cases of the screen-door-closed and open were respectively investigated. A total of 7.5million grids were generated and the whole domain divided into 22 blocks for MPI efficiency of calculation. Large eddy simulation (LES) was applied to solve the momentum and energy equation.

The Experimental Study on the Leakage of Automatic Pressure Differential·Overpressure Control Dampers by Increasing the Number of Damper Operation (자동차압·과압조절형댐퍼의 개폐동작횟수 증가에 따른 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.56-61
    • /
    • 2016
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of above 40 Pa, but pressure differential is excessively overpressure in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by increasing the number of dampers operation for identifying this problems. The result of testing, the leakage has difference between new dampers and increased the number of operation dampers. As the static preassure increase, the leakage difference increase. Comparison with preceding study, this result has similar linear tendency.

A Study on the Fire Door Performance Method of Pressurized Room for Special Evacuation Stairwells (특별 피난계단의 부속실 출입문 성능 방안에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Ryou, Hong-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.12-16
    • /
    • 2010
  • 본 연구에서는 건설현장의 특별 피난계단 출입문 크기와 구조의 다양성을 고려한 자동폐쇄장치의 설계방안을 제시하였다. 이를 위해서 급기가압실의 방연풍속, 누설량 그리고 송풍기의 용량이 일정한 경우 출입문이 폐쇄되기 위한 힘의 상관관계를 회전각도와 회전속도의 변화에 따라서 분석하였으며, 방화문의 폭이 1,100 mm, 1,300 mm 인 경우 각각에 대해서 개방력과 폐쇄력을 측정하였다. 그 결과 현장 조건을 만족할 수 있는 자동폐쇄장치에 의한 방화문의 폐쇄조건 및 회전각도와 회전속도의 변화를 고려한 개방력과 폐쇄력의 최적 설계범위가 존재함을 확인하였다.

  • PDF