• Title/Summary/Keyword: 급격연소

Search Result 172, Processing Time 0.024 seconds

[Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire ([논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율)

  • Kong, Ha-Sung;Gong, Ye-Som;Kim, Sang-Heon
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.57-60
    • /
    • 2015
  • The removal efficiencies by elastic fire gas mask of toxic gases CO, HCl, HCN, and $SO_2$ produced by a fire have a key role in saving lives. The elastic fire gas mask comprises a visible window, elastic hood, gas purification canister, and air vent. It does not have hair or neck thongs, which makes it easy to use and put on quickly. This research examined the removal efficiency of toxic gases by such a mask. The removal efficiencies for CO with a background concentration of 2505.0 ppm were 99.99 and 99.98% after 3.5 and 8.5 min, respectively. The residual CO concentration was drastically increased after 8.5 min. The removal efficiencies for HCl, HCN, and $SO_2$ with background concentrations of 1003.0, 399.0, and 100.3 ppm, respectively, were 100% after 20 min.

Effect of economic growth, industrial structure, efficiency improvement, decarbonization of power sector and fuel substitution for the transition to low carbon society by 2050 (2050년 저탄소 사회로의 전환을 위한 경제성장, 산업구조, 효율개선, 전력 탈탄소화와 연료 대체의 효과)

  • Park, Nyun-Bae;Hong, Sungjun;Park, Sang Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • This paper analyzed transition pathways toward a low carbon society in Korea to meet global $2^{\circ}C$ climate target. Lower economic growth, industrial structure change, enhance of energy demand management, decarbonization of power sector, and replacement of low carbon fuel could reduce greenhouse gas (GHG) emission from fuel combustion in 2050 by 67% against in 2011, or by 74% against in BAU (Business-As-Usual). Lower economic growth contributes to 13% of cumulative emission reduction relative to BAU, industrial structure change 9%, enhance of energy demand management 72%, decarbonization of power sector 5% and replacement of low carbon fuel 1% respectively. Final energy consumption in 2050 needs to be reduced to 50% relative to 2011, or to 41% relative to BAU. Nuclear, coal and renewable energy represent 31%, 40%, 2% respectively among electricity generation in 2011, but 38%, 2%, 32% in 2050. CCS represents 23% of total generation in 2050. Emission intensity of electricity in 2050 was decreased to 19% relative to 2011, or to 24% relative to BAU. Primary energy in 2050 was decreased to 64% compared to 2011, or to 44% compared to BAU. Final energy consumption, primary energy supply and GHG emission from fuel combustion from 1990 to 2011 increased by 176%, 197%, 146%. Radical change from historical trend is required to transit toward a low carbon society by 2050. Appropriate economic growth, structural change to non-energy intensive industries, energy technology research, development and deployment (RD&D) in terms of enhancement of energy efficiency and low carbon energy supply technologies, and fuel change to electricity and renewable energy are key instruments.

Study on Manufacturing Emulsion Oil Using Biodiesel Feedstock Oil Production By-product (바이오디젤 원료유 생산 부산물을 이용한 유화유 제조 연구)

  • Kim, Deogkeun;Jeon, Sanggoo;Yoon, Sangjun;Park, Soonchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.106.2-106.2
    • /
    • 2010
  • 동식물성 기름과 메탄올의 전이에스테르화 반응에 의해 생산되는 바이오디젤은 환경친화성과 지속가능성이 인정됨에 따라 그 생산량이 급격히 증가하고 있어 대두유, 유채유, 팜유 등의 원료유 부족과 가격 상승, 수급 불안정 등의 문제가 대두되고 있다. 이를 해결하기 위한 방안으로 유리지방산 함량이 높은 저가유지 자원(폐식용유, 폐돈지, 폐우지, soapstock, trapped grease)과 새로운 오일 작물을 이용한 생산 기술 연구가 활발히 진행되고 있다. 본 연구에서는 비활용 해외 열대작물 씨앗에서 착유한 식물성 오일을 정제하여 바이오디젤 원료유를 생산하는 과정에서 발생하는 폐기물(폐유, 폐수)의 경제적 처리 방안으로 유화유 제조 원료(벙커C유, 물)와 유화유 제조 첨가제(무기계, 유기계)로 활용 가능성을 검토하였다. 열대작물 오일의 물성 분석 결과 고형물, 수분, 인지질(phospholipid), 유리지방산(free fatty acid) 함량이 기존 원료유보다 매우 높게 나타났다. 인지질은 바이오디젤 제조 반응후 에스테르와 글리세린의 층분리를 방해하고 유리지방산은 염기촉매와 결합하여 지방산염을 생성해 생산 수율을 감소시킨다. 고형물과 수분 역시 촉매반응에 악영향을 가지나 여과와 감압증발에 의해 쉽게 제거가 가능하다. 유리지방산은 산촉매 에스테르화 반응에 의해 제거가 가능하다. 인지질은 탈검(degumming) 과정을 통해 제거하며 탈검은 수용성 탈검, 산 탈검, 세정 공정으로 구성된다. 착유한 원료유의 고형물을 제거 후 물과 수세하여 수용성 인지질을 수화하여 층 분리해 제거하고 상층의 오일은 추가적인 산 탈검을 수행한다. 그 뒤 세정을 통해 사용된 탈검제인 산과 추가적으로 수화된 인지질을 제거하게 된다. 이러한 3단계의 탈검 과정에서 하층으로 오일과 물이 폐기물로서 배출되며 본 연구에서는 배출 폐기물을 다시 층분리하여 오일층과 물 층으로 구분하여 유화유 제조에 사용되는 벙커C유, 물, 그리고 기존 유기계 및 무기계 유화제의 대체 가능성을 조사하였다. 유화 연료유는 기름과 물을 균일한 분산상으로 혼합한 연료유로 연소시 오일계 성분의 미연분을 감소시켜 연료 효율 제고와 배출가스 성상을 개선하기 위해 개발되어 왔다. 본 발표에서는 다양한 종류의 상용 첨가제 및 바이오디젤 원료유 생산 폐기물을 활용해 유화 연료유를 제조하였으며 각 유화유의 장시간의 상(phase) 안정성을 비교하였다. 바이오 폐기물 중에는 천연 계면활성제(surfactant)인 인지질이 다량 함유되어 있어 기존의 무기계 및 유기계 유화제보다 상 안정성이 우수하게 나타났으며 바이오디젤 원료유 생산 공정의 폐기물인 폐유과 폐수의 활용이 가능한 것으로 나타났다.

  • PDF

Flame and Carbonization Patterns of Animal-Origin Foods Ignited by Overheating (과열에 의해 발화된 동물성 식품의 화염 및 탄화 패턴에 관한 연구)

  • Lee, Jeong-Hun;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.126-131
    • /
    • 2019
  • Real-scale fire tests were performed on animal-origin foods using a gas stove with no overheating prevention device. When the animal-origin foods were ignited, a large quantity of white smoke and steam was generated from them; however, when they became dry and began to carbonize, a dark smoke was generated. Even after the gas stove was overheated for more than 5400 s, mackerel, pollack, chicken, etc., did not ignite. However, pork, beef, and tuna caught fire after 2643 s, 2819 s, and 6492 s of heating, respectively. The flame patterns of animal-origin foods were in the forms of a mixed laminar flow and a turbulent flow, and a halo pattern was produced. A sand glass form of the flame pattern was generated when a kitchen hood was operated, but a triangular flame pattern was produced when the kitchen hood was not operated. When the tuna in the pot was overheated, it spontaneously ignited after 6492 s, with the surface temperature of the kitchen hood rapidly rising to 464.5 ℃. Moreover, the temperature at the back of the pot, which was 6 cm away from the outer surface of the upper part of the pot, was 869 ℃ after 6660 s because of the radiant heat. The flame formed a sand glass pattern on the kitchen wall. When the kitchen hood was not operated, or when the flame grew lower than the height of the ceiling, a triangular pattern was formed.

Studies on the Environmentally and Ecologically Stable Revegetation Measures on Rock Cut-Slopes - Effect of Hydroseeding Measures with Forest Topsoil - (암절취(岩切取) 훼손(毁損)비탈면에 대한 환경생태적(環境生態的)으로 안정(安定)된 녹화공법(綠化工法)에 관(關)한 연구(硏究) (II) - 산림표층토(山林表層土)를 이용한 종비토(種肥土)뿜어붙이기공법(工法)의 시공효과(施工效果) 분석(分析) -)

  • Woo, Bo-Myeong;Kim, Kyung-Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.3
    • /
    • pp.383-390
    • /
    • 1998
  • The purpose of this study was to evaluate the effect of new materials with forest topsoil for hydroseeding measures that is environmentally and ecologically stable revegetation measures on rock cut-slopes. Field hydroseeding experiment was used with a completely randomized design at highway rock cut-slopes in April, 1997. Results obtained in this study were summarized as follows: Particle size distribution of 3 mixed-soil materials that consisted of forest topsoil, decomposed granite soil, compost, sludge, and bottom ash did not show a significant difference. As appending the amount of forest topsoil, soil bulk density was increased. Soil hardness was slightly increased in early period, and then decreased with the flourishing of plants. The number of individuals increased, more than $3,000seedlings/m^2$, after 1 month, and it was decreased as time passes because of competition between the seeded species and the naturally emerged species. In addition to the seeded species, seeding plot has more than 6 species (Rubus crataegifolius, Eleusine indica, Erigeron canadensis, Lycopersicon esculentum var. cerasiforme, etc.) per $m^2$ were naturally appeared in the first year. From the viewpoint of species diversity promotion, the capability of using forest topsoil as seed bank sources was high. In order to apply in the field, the investigation and analysis of topsoil availability (quantity and quality of seed source, soil texture and organic composition) should be carried out before-hand.

  • PDF

Study on the Defect Improvement of Fuel Flow Proportioner Install Structure on Aircraft (항공기 연료흐름분배기 장착 구조물 결함개선 연구)

  • Choi, Hyoung Jun;Lee, Jin Won;Choi, Jae Ho;Park, Sung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.558-567
    • /
    • 2020
  • This study examined the defect characteristics of fuel flow proportioner-mounted structures to analyze the causes of structural defects during aircraft operation. System vibrations and single component vibrations that occur during aircraft operations are usually the cause of structural defects. The fuel flow proportioner causes a defect in the support structure due to the vibration caused by the pressure change caused by the sudden increase in the flow rate. Defects in the support structure of the fuel flow proportioner are not correlated directly with the cracking of the maneuver, and flight time according to aircraft operation analysis is related to the use of A/B. The structural reinforcement configuration was confirmed through static and life analysis of the cracks of the bracket mounted under the fuel flow proportioner for improvement of the defect. An analysis of the reinforcement revealed a minimum structural strength of +0.15. Structural life analysis confirmed that the stress acted on the site under 15Ksi. The fatigue life was confirmed to be more than 7,700 Cycles.

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

A Study on the Pozzolan Reactivity and Mechanical Characteristic of Blended Portland Cements using CFBC Fly Ash (순환유동층 플라이 애시를 사용한 혼합시멘트의 포졸란 반응성과 역학적 성질에 관한 연구)

  • Park, JongTak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.207-213
    • /
    • 2018
  • Nowadays, circulating fluidized bed combustor(CFBC) boilers system that can reduce environmental pollution particles are widely used in electric power plants. But the fly ash generated from CFBC boilers has lower $SiO_2$ and higher MgO and $SO_3$ contents and also has free CaO inducing expansion and abrupt initial setting of concrete. Therefore, revised KSL5405 for CFBC fly-ash as well as pulverized coal combustion(PCC) is introduced in the concrete field. In this study, the chemical properties and mechanical properties of blended cements with PCC and CFBC fly-ash produced in Korea are analyzed. The blended cement with only CFBC fly ash shows a lower length change than OPC but a higher flow change ratio. The compressive strength of blended cement paste with PCC and CFBC fly ash is slightly greater than that of cement paste with only PCC fly-ash. Based on the results, CFBC flyash blended cement products should be used with PCC flyash to ensure the material stability and material properties.

Performance Characteristics of the 300 MW Integrated Gasification Combined Cycle Plant according to Ambient Temperature (대기온도에 따른 300 MW 석탄가스화복합발전 성능특성)

  • Kim, Young-Mook;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.3
    • /
    • pp.29-34
    • /
    • 2018
  • In this study, the output and thermal efficiency of Taean Integrated Gasification Combined Cycle Plant were calculated by using the manufacturer's basic design data and the performance correction factor for each atmospheric temperature, and the actual performance was measured at summer and winter representative points. The results were compared with the calculated values to verify their validity. The thermal efficiency is the highest at around $15^{\circ}C$ and lower at lower temperature and higher temperature. This is similar to that of natural gas Combined Cycle Power Plant, but the thermal efficiency has drastically decreased due to the increase of power consumption of the air separation unit at relatively high temperature. The output is highest in the range of 5 to $15^{\circ}C$, and is kept almost constant at below $5^{\circ}C$ and declines above $15^{\circ}C$. The reason why the output does not increase at low temperatures is that the torque limit of the shaft is activated by the increase of the flow rate due to the nitrogen injection of the gas turbine combustor. In order to improve the performance in the future, efforts should be made to improve the power generation output and to reduce the power consumption of the air separation unit in summer.

  • PDF

Potential Element Retention by Weathered Pulverised Fuel Ash : II. Column Leaching Experiments (풍화 석탄연소 고형폐기물(Pulverised Fuel Ash)의 중금속 제거가능성 : II. 주상용출실험)

  • Lee, Sanghoon
    • Economic and Environmental Geology
    • /
    • v.28 no.3
    • /
    • pp.259-269
    • /
    • 1995
  • Column leaching tests were conducted using fresh and weathered pulverised fuel ash of some 17 and 40 years old from two major British power plants, with deionised water and simulated synthetic industrial leachate. The former was to see the leaching behaviour of weathered ash and the latter was to see if the formation of secondary products from water and PFA interaction and ameliorating effect in removing metals from industrial leachates. Fresh PFA liberates elevated concentrations of surface-enriched inorganics, including Ca, Na, K, B, $Cr_{total}$, Li Mo, Se and $SO^{2-}_4$. This might indicate their association with the surface of PFA particles. In the column leaching tests using weathered ash and deionised water, elements are not readily leached but are released more slowly, showing relatively constant concentrations. For the case of weathered ash, some readily soluble surface-enriched elements appears to have been liberated in their early stage of leaching and the liberation of glass associated elements are thought to be more important function in controlling the element concentration. The result from column leaching tests exceed for a number of elements when compared with various Water Standards and suggests the leachate from PFA disposal mound needs dilution to achieve target concentrations. PF A shows element retention effect for many elements, including B, Fe, Zn, Hg, Ni, Li and Mo, in the order of fresh Drax ash > weathered Drax ash > Weathered Meaford ash in retaining capacity. Geochemical modelling using a computer program WATEQ4F reveals some solubility controlling secondary solid products. These include $CaSO_4{\cdot}2H_2O$ for Ca, $Al(OH)_3$ for Al and $Fe(OH)_3$ for Fe.

  • PDF