• Title/Summary/Keyword: 급격연소

Search Result 172, Processing Time 0.031 seconds

An Experimental Study on Fire Risks Due to Overcharge and External Heat of ESS Lithium Battery (ESS 리튬배터리의 과충전 및 외부수열에 따른 화재위험성에 관한 실험적 연구)

  • Kim, Si-Kuk;Choi, Su-Gil;Jin, Se-Young;Bang, Suck-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.59-69
    • /
    • 2019
  • The present article relates to an experimental study on fire risks due to overcharge and external heat of ESS lithium battery. According to the experimental results of overcharge, ignition occurred as combustible gas and smoke was slowly increased after occurrence of venting, and an explosive combustion form accompanied by flame eruption and sparks was displayed as charged energy is rapidly discharged in an instant. On the other hand, according to the experimental results of external heat, as a tremendous amount of combustible gas and smoke was ignited following being discharged after occurrence of vent, the charged energy itself was rapidly reduced due to the discharged energy so that a passive combustion form was observed when compared with overcharge after occurrence of flames. According the analysis results of fire damage characteristics, differences between external heat (External flame) could be found through visual and X-ray inspections. Namely, while inside electrode plate was completely destroyed and perforation of the electrode plate was observed in the case of overcharge, fire damage of the electrode plate was not severe maintaining the form in the case of external heat.

A study on desulfurization by anthracite - bituminous coal blend combustion in a fluidized bed combustor --- A desulfurization using waste paper sludge --- (유동층연소로에서 유,무연탄 혼합연소시 탈황에 관한 연구 --- 폐제지슬러지를 이용한 황산화물 제어 ---)

  • Cho, Sang-Won;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.3 no.1
    • /
    • pp.96-105
    • /
    • 1997
  • The objectives of this study were to investigate $SO_2$ removal efficiency of anthracite - bituminous coal blend combustion in a fludized bed coal combustor with Ca/S, anthracite ratio, bed temperature, and waste paper sludge particle size. The experimental results were presented as follow ; the effect of the desulfurization by the particle size of waste paper sludge was a great and $SO_2$ removal efficiency was heigest in paper sludge dia $1016{\mu}m$. And the difference of $SO_2$ removal efficiency according to air velocity was not too large. As Ca/S mole ratio incresed, $SO_2$ removal efficiency incresed rapidly up to Ca/S mole ratio 3 while the desulfurization rates did not increse too largely in the range of more than the level. The bed temperature had a great deal of effect on the desulfurization rate. So the $SO_2$ removal efficiency was a graet using waste paper sludge that the properbility of paper sludge as sorbent was conformed.

  • PDF

Experimental Study on the Flame Spread Characteristics under Reduced Atmospheric Pressures and Elevated Oxygen Concentrations (저기압 고산소 환경에서 화염 전파특성에 관한 실험적 연구)

  • Yang, Ho-Dong;Kwon, Hang-June;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.78-83
    • /
    • 2016
  • The characteristics of flame spread under similar atmospheric conditions to those inside the first stage of launch vehicles were investigated to provide fundamental knowledge to prevent fires and explosions of vehicles during launching operations. To this end, the rate of flame spread on the solid fuel was measured at elevated oxygen concentrations and reduced atmospheric pressures. A 0.18 mm diameter optical fiber was used as a solid fuel. The experimental results indicated that elevated oxygen concentrations can increase the rate of flame spread while increasing the atmospheric pressures to 1 atm can lead to decreases in the rate of flame spread. The increases in the rate of flame spread with pressure is due mainly to reductions in the convective heat loss that are clarified through an analysis of the pressure dependence on the convective heat transfer coefficient.

Performance Characteristics Under Non-Reacting Condition with Respect to Length of a Subscale Diffuser for High-Altitude Simulation (고고도 모사를 위한 축소형 디퓨저의 길이변화에 따른 비연소장에서의 성능특성)

  • Jeong, Bonggoo;Kim, Hong Jip;Jeon, Junsu;Ko, Youngsung;Han, Yeoung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.321-328
    • /
    • 2014
  • The performance characteristics of a subscale diffuser under non-reacting conditions for high-altitude simulation were numerically investigated with respect to different lengths of the secondary throat diffuser. The ratio of the length of the diffuser entrance to the nozzle exit diameter was set to 0, 50, and 100%. In addition, flow characteristics were studied for a range of length-to-diameter ratios of the secondary throat diffuser. An insufficient diffuser entrance length caused contraction of the plume immediately after the nozzle exit. When the length-to-diameter ratio was less than 8, a strong Mach disk was formed inside the diffuser, resulting in a sharp increase in pressure. In addition, flow characteristics in the diverging part of the diffuser were investigated for a range of diverging part lengths. A short diverging part may lead to abrupt pressure recovery, resulting in the possible application of mechanical load to the diffuser.

Fire Patterns According to the Blood Hb-CO Concentration of Charred Bodies (소사체의 혈중 헤모글로빈-일산화탄소 농도에 따른 연소형태 연구)

  • Choi, Seung-Bok;Oh, Bu-Yeol;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.40-48
    • /
    • 2012
  • Fire patterns have been used to determine the origin and cause of fires in every setting imaginable. However, it is very difficult to identify fire patterns and causes from the fire-damaged remains of a devastated structure. If someone was killed by the fire, it is possible to identify fire patterns by analyzing the Hb-CO concentration in charred bodies of deceased as well as the pace of the fire. For example, a low level of Hb-CO concentration in the charred bodies indicate a rapid fire with accelerants and the death was caused by severe heat and thick toxic fumes. However, a high level of Hb-CO concentration in the charred bodies demonstrates that the fire was slow and/or there was a flameless form of combustion. Thus, it is possible to identify fire patterns through analyzing the level of Hb-CO concentration on the dead from the fire. In this study, the Hb-CO concentration in the charred bodies was from 3 % at the case of gas burning oneself to death to 93 % at the death caused by smoldering fire.

A Study on the Oxidation Behavior of Metal Materials Applicable to Oxidizer Rich Pre-Combustor (산화제 과잉 연소기에 활용 가능한 금속재료의 산화 거동에 관한 연구)

  • Shin, Donghae;Yu, Isang;Shin, Minku;Ko, Youngsung;So, Younseok;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.118-125
    • /
    • 2019
  • Metals exposed to high temperature/high pressure/oxidant excess environment of an oxygen excess pre-combustor may undergo rapid oxidation. In this study, the test facility to simulate the high temperature/high pressure/oxidant excess environment was constructed and the oxidation resistance evaluation was carried out for various metal materials. As a result, the discoloration of the metallic materials, the change in the surface roughness and the peeling of the metal surface were observed, and the weight change was also observed. The resulst showed that oxidation-resistant coating of a metal material of the combustor is indispensably required, and the use of XM-19, which has the highest content of Cr and Ni, is expected to provide more structural stability.

A Study on the Response Characteristics of 200MW Gas Turbine Governor System (200MW급 가스터빈 조속기 응답특성에 대한 연구)

  • Han, Young-Bok;Nam, Kang-Hyun;Kim, Sung-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.625-632
    • /
    • 2022
  • Gas turbine generators in load-following operation in the domestic power system play a major role in maintaining the rated frequency, but often have poor frequency control. Therefore, after examining the control characteristics of the governor, which is a gas turbine speed control device, and analyzing the failure types, countermeasures were suggested for each case. In addition, it was confirmed through the governor response test that the gas turbine helps in frequency recovery depending on the speed of fuel control, but also acts as a factor impeding stable operation, such as rapid fluctuations in combustion chamber temperature and combustion vibration. Therefore, in order to maintain stable power quality, there was a need for thorough facility management as well as research on the governor control method in which the traditional PID control method and the machine learning algorithm, a core field of the 4th industry, were fused.

Local Behaviour of Propagating Flames in an Explosion Chamber (폭발챔버에서 전파하는 화염의 국부 거동)

  • Park, Dal-Jae;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.32-35
    • /
    • 2011
  • Experimental studies were carried out in an explosion chamber to investigate the influences of multiple cylinder obstacles on local flame propagation. The chamber dimension is 235 mm in height with a $1,000{\times}950\;mm^2$ rectangular cross section and a large vent area of $1,000{\times}320\;mm^2$. Multiple cylinder bars with obstruction ratio of 30% were used. In order to examine the interaction between the propagating flames and the obstacles, temporally resolved flame front images were recorded by a high speed video camera. The propagation behaviour of local flame fronts around the left obstacle was analyzed in terms of two different methods such as the incremental burnt area divided by the flame front length and the average of the local propagation velocity determined at each point along the flame front. It was found that two methods give good consistency.

Reduced-Scale Experiments of the Partial Smoke Extraction System in Tunnel Fires (풀화재를 이용한 터널화재 부분배연 모델실험)

  • Lee, Eui-Ju;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.58-64
    • /
    • 2006
  • Smoke extraction in tunnel fire is investigated experimently with thermal model. The object is a immersed tunnel, of which the partial extraction system exists between the tubes. The model tunnel is measured 12 m long, 0.5 m wide and 0.35 m high. The fire is simulated to pool fire and the size corresponds to full scale fire of 5 MW based on Froude modeling. The performance of partial extraction system is determined under two ventilations, natural and longitudinal ones. The results show that compared with longitudinal ventilation, the smoke extraction efficiency of natural ventilation is increased about 30% because of smoke stratification in tunnel. Also the efficiency is identical to the iso-thermal model. The results will be help for activation of the ventilation system in emergency such as in the event of tunnel fires.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF